Tumor Motion Management in Radiotherapy Using 4D-MRI

Evaluation of Tumor Motion Management Strategies in Radiotherapy Using 4D-MRI

The main goal of this research is to characterize patient-specific respiration-induced tumor and surrogate motion to evaluate the accuracy and effectiveness of the surrogate-based motion management strategies currently used in clinics. Specifically, the investigators hypothesize that dynamic MRI (Magnetic Resonance Imaging) obtained over a temporal duration consistent with radiotherapy treatments will provide spatio-temporal information of both the tumor and surrogate, and therefore can serve as a means to assess the quality of the tumor motion tracking with the surrogate. To test this hypothesis, the investigators specifically propose to 1) track and characterize the tumor and surrogate motion with 4D (4 dimensional)-MRI and 2) evaluate surrogate-based motion tracking in a cohort of patients with thoracic tumors.

External and internal surrogate-based strategies commonly used in clinics have not been appropriately validated. With the increasing adaptation of these surrogate methods for motion management, the proposed research addresses these urgent issues in clinical radiotherapy while providing a means to achieve patient-specific motion management.

Aperçu de l'étude

Statut

Complété

Les conditions

Description détaillée

Respiration-induced patient motion has become a major obstacle for achieving high-precision radiotherapy of cancers especially in the thorax and upper abdomen. As the target is continuously moving, an additional margin has to be added to the clinical target volume to compensate for the uncertainty in the tumor and organ motion, causing toxicity to the normal tissue and limiting the dose delivered to the target. To account for the tumor motion, surrogate tracking methods are commonly used in clinics during radiotherapy. However, the relationship between the surrogate and tumor motion is hard to generalize as it depends on individual patients, tumor location, treatment fractions, and sometimes shows complex patterns or transient, unpredictable changes. Hence, there is an urgent need to better scrutinize the current surrogate-based motion management strategies. Moreover, the most robust motion management strategy for the given patient should be determined in the pre-treatment setting but the investigators currently lack a sufficient tool to provide this information.

4D-CT is typically used to characterize the tumor motion over the course of the radiotherapy. However, 4D-CT is an oversimplified snapshot representation of a single-breathing cycle with low soft tissue contrast while imparting a considerable amount of radiation dose to the patient. Consequently, the limitations of 4D-CT prevent applicability in acquiring information over timescales that represent a treatment session. MRI is highly advantageous as it is non-ionizing and provides excellent soft tissue contrast. Although real-time 3D dynamic MRI is limited by low image quality and temporal resolution, 2D dynamic MRI techniques have high fidelity and spatio-temporal resolution requisite for real-time tracking of the moving target. Furthermore, a respiration-correlated 4D-MRI can be reconstructed from multi-slice 2D dynamic MR images, enabling volumetric image processing and analysis. Therefore, 4D-MRI is an attractive solution to address breathing motion and tumor tracking obstacles in radiotherapy.

The main goal of this research is to characterize patient-specific respiration-induced tumor and surrogate motion to evaluate the accuracy and effectiveness of the surrogate-based motion management strategies currently used in clinics. Specifically, the investigators hypothesize that dynamic MRI obtained over a temporal duration consistent with radiotherapy treatments will provide spatio-temporal information of both the tumor and surrogate, and therefore can serve as a means to assess the quality of the tumor motion tracking with the surrogate. To test their hypothesis, the investigators specifically propose to 1) track and characterize the tumor and surrogate motion with 4D-MRI and 2) evaluate surrogate-based motion tracking in a cohort of patients with thoracic tumors.

External and internal surrogate-based strategies commonly used in clinics have not been appropriately validated. With the increasing adaptation of these surrogate methods for motion management, the proposed research addresses these urgent issues in clinical radiotherapy while providing a means to achieve patient-specific motion management.

Type d'étude

Observationnel

Inscription (Réel)

32

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • Maryland
      • Baltimore, Maryland, États-Unis, 21287
        • The Sidney Kimmel Comprehensive Cancer Center at Johns Hopkins

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

18 ans à 100 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Patients with cancer being treated with radiotherapy

La description

Inclusion Criteria:

  • Histologically-confirmed primary lung cancer (non-small cell OR small cell)
  • Plan to undergo external radiation treatment of lung cancer

Exclusion Criteria:

  • Patients who cannot undergo MRIs.
  • Patients who have a cardiac device or other electronic or metal implant

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Tumor motion characterization during radiation therapy
Délai: 1 year
To characterize patient-specific respiration-induced tumor and surrogate motion to evaluate the accuracy and effectiveness of the surrogate-based motion management strategies currently used in radiotherapy.
1 year

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Correlation of tumor and surrogate motion
Délai: 1 year
Tumor and surrogate motion will be quantified by measuring the displacements from their end-exhale positions. Since the tumor may deform during motion, we will not only consider the trajectories of the center of mass but also the tumor borders. The tumor position as a function of the surrogate position will be analyzed along each moving direction. Pearson correlation coefficients and the sum of squared residual errors based on a regression analysis will be computed to provide a quantitative measure of the correlation between the surrogate and tumor positions. To measure the tumor deformation, correlations of the motion between the SI borders, AP borders, LR borders will also be computed. Although lung tumor likely does not significantly deform, this analysis will be useful for tumors that may deform significantly during motion. The motion under the different breathing patterns will be analyzed separately, and compared to each other.
1 year
Sensitivity and specificity of gating
Délai: 1 year
Respiratory gating is one predominant technique for managing respiratory motion. Gating attempts to minimize normal tissue dose by delivering radiation during a portion of the respiratory cycle where the respiratory state is typically determined from an external surrogate as an optical signal. We will use different gating boundaries, e.g. 10%, 20% of the surrogate motion range (from mean exhale to mean inhale) on each axes as commonly used in clinical practice. Sensitivity and specificity of the gating will be computed by comparing the portion of time the surrogate is below/above the gating boundary and that the tumor is below/above the gating boundary.
1 year
Pre- and intra-treatment motion variability
Délai: 1 year
MRI scans of the patient will be acquired pre- and intra-treatment. Tumor motion variability will be computed between these two scans. We will evaluate the correlation of the target location captured at different time points by computing target volume overlap and systematic volume shift. We will also analyze the tumor position as a function of the surrogate position for both pre- and intra-treatment scans, and will investigate how well these two distributions match. To quantitatively measure the differences, we will compute various statistical similarity measures such as correlation coefficient and mutual information. We will also calculate pre-treatment margins to account for the tumor motion using the pre-treatment retrospective 4D-MRI reconstruction, and calculate the portion of treatment time the tumor moves within or outside the specified margins during the successive scans.
1 year

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Les enquêteurs

  • Chercheur principal: Russell Hales, M.D., Johns Hopkins University

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 octobre 2013

Achèvement primaire (Réel)

1 octobre 2015

Achèvement de l'étude (Réel)

1 octobre 2015

Dates d'inscription aux études

Première soumission

30 août 2013

Première soumission répondant aux critères de contrôle qualité

3 septembre 2013

Première publication (Estimation)

4 septembre 2013

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

12 octobre 2015

Dernière mise à jour soumise répondant aux critères de contrôle qualité

9 octobre 2015

Dernière vérification

1 octobre 2015

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • J1370
  • NA_00085958 (Autre identifiant: Johns Hopkins Institutional Review Board)

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .