Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Impact of Neuromuscular Control With and Without Electrical Stimulation and Long-term Effect of Kinetic Chain Exercises in Multidirectional Shoulder Instability Patients

20 mai 2026 mis à jour par: National Taiwan University Hospital

Background: Shoulder instability is commonly observed in adolescents and young females, ranging from asymptomatic multidirectional instability (MDI) to symptomatic conditions. Patients with MDI often experience shoulder pain, muscle tension, and episodes of subluxation. This condition is associated with hypermobility spectrum disorder (HSD) and hypermobile Ehlers-Danlos syndrome (hEDS), both characterized by generalized joint laxity and recurrent joint dislocations, significantly affecting daily activities and athletic performance. Current literature lacks clarity on the actual humeral head displacement, shoulder joint kinetics, and muscle activity characteristics during movement in patients with MDI accompanied by HSD or hEDS. Additionally, the effects of electrical stimulation on different shoulder muscles and its impact on humeral head displacement in MDI patients remain to be validated.

Objective: The purposes of this study are to (1) examine whether patients with hEDS/HSD and MDI have increased humeral head translation compared to healthy controls during three isometric contraction ; (2) investigate the relationship between humeral head translation and associated muscle activity during three isometric exercises ; (3) examine the effect of NMES and NMCT to humerus/scapula muscles on humeral head translations in MDI patients with hEDS/HSD Outcome measurements: The primary outcomes include changes in acromiohumeral distance (AHD) or humeroglenoid distance (HGD) under four conditions (no stimulation, NMCT, BLH/Infraspinatus/MD stimulation, and SA stimulation) during three isometric contractions (shoulder flexion, horizontal adduction, and fully extended elbow holding weight).

The secondary outcomes assess muscle activation differences in BLH, infraspinatus, MD, UT, LT, and SA before and after NMCT.

Aperçu de l'étude

Type d'étude

Interventionnel

Inscription (Estimé)

60

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

      • Taipei, Taïwan, 100
        • Recrutement
        • School and graduate institution of physical therapy
        • Contact:

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

  • Age: Between 20 and 50 years old.

Patients with Multidirectional Shoulder Instability Must Meet the Following Conditions:

(A) Generalized Joint Hypermobility: Beighton score ≥ 4/9. (B) Shoulder Laxity Verified in at Least Two Directions During Clinical Examination (must meet A and B, or A and C): Inferior: Presence of a sulcus sign under the acromion or a positive Gagey hyperabduction test.

Anterior: Positive anterior load and shift test or active shoulder external rotation > 85 degrees or passive shoulder external rotation > 90 degrees.

Posterior: Positive posterior load and shift test or positive posterior jerk test.

(C) Shoulder Pain for at Least Three Months Before the Start of the Study. (D) Signs of Shoulder Instability in Daily Life Without a Traumatic Cause. (E) Ability to Raise the Arm Above 120 Degrees Without Experiencing Subluxation or Dislocation of the Shoulder.

Exclusion Criteria:

  • Shoulder pain caused by trauma. History of shoulder fractures or dislocations. Cervical radiculopathy. Degenerative joint disease of the shoulder. Previous shoulder surgery. Frozen shoulder. Pain score greater than 5 during experimental movements. Redness, swelling, or open wounds on the skin within the experimental area. Sensory abnormalities. Cognitive impairment.

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Double

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: multidirectional instability with HSD
The GM300TE COMBO NMES (Gemore Technology Co., Ltd., New Taipei City, Taiwan), a portable machine with dual controllable channels and a manual switch, will be applied to the biceps long head, infraspinatus, middle deltoid, LT and SA. Muscle force generation is modulated by stimulated frequency, pulse width, and intensity [Bdaiwi et al., 2015]. It linearly increases with stimulated amplitude and pulse duration. The electronics of the unit creates the electrical impulses with an output frequency of 50 Hz and a pulse width of 300 microseconds. The synchronous (S) mode and asymmetrical rectangular wave-pulse will be used throughout the experiment following protocol from previous research (Bdaiwi, et al., 2015). The amplitude will be settled as muscle motor-level contraction with self-perception of maximal tolerable intensity. The time of tetanic stimulation is 7 seconds with 20-second intervals between stimulations to avoid muscle fatigue. The two circular electrodes are used on each muscl
To ensure that the humeral head remains centered during the three specific isometric tasks, the examiner positioned the shoulder according to the direction of instability (anterior, inferior, or posterior) by placing the arm in 20° of shoulder flexion, 0° (neutral), or 10° of extension, respectively. In each position, the examiner gently applied a downward force on the upper arm in a horizontal direction, and the participant was instructed to gently resist the force. The goal was to guide the humeral head gradually toward the center of the glenoid, without excessive scapular movement. This training was directly supervised by a physical therapist, who provided verbal and tactile feedback to ensure correct movement execution (Figure 1). The physical therapist was also responsible for conducting the USG assessment. After a 5-minute familiarization session, participants performed the designated instability-specific isometric task for 3 repetitions.
Comparateur actif: patients with multidirectional instability
The GM300TE COMBO NMES (Gemore Technology Co., Ltd., New Taipei City, Taiwan), a portable machine with dual controllable channels and a manual switch, will be applied to the biceps long head, infraspinatus, middle deltoid, LT and SA. Muscle force generation is modulated by stimulated frequency, pulse width, and intensity [Bdaiwi et al., 2015]. It linearly increases with stimulated amplitude and pulse duration. The electronics of the unit creates the electrical impulses with an output frequency of 50 Hz and a pulse width of 300 microseconds. The synchronous (S) mode and asymmetrical rectangular wave-pulse will be used throughout the experiment following protocol from previous research (Bdaiwi, et al., 2015). The amplitude will be settled as muscle motor-level contraction with self-perception of maximal tolerable intensity. The time of tetanic stimulation is 7 seconds with 20-second intervals between stimulations to avoid muscle fatigue. The two circular electrodes are used on each muscl
To ensure that the humeral head remains centered during the three specific isometric tasks, the examiner positioned the shoulder according to the direction of instability (anterior, inferior, or posterior) by placing the arm in 20° of shoulder flexion, 0° (neutral), or 10° of extension, respectively. In each position, the examiner gently applied a downward force on the upper arm in a horizontal direction, and the participant was instructed to gently resist the force. The goal was to guide the humeral head gradually toward the center of the glenoid, without excessive scapular movement. This training was directly supervised by a physical therapist, who provided verbal and tactile feedback to ensure correct movement execution (Figure 1). The physical therapist was also responsible for conducting the USG assessment. After a 5-minute familiarization session, participants performed the designated instability-specific isometric task for 3 repetitions.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Western Ontario Shoulder Index (WOSI)
Délai: At baseline, week 4, and week 8 after the intervention
The Western Ontario Shoulder Instability Index (WOSI) is a patient-reported questionnaire used to evaluate shoulder-related quality of life in individuals with shoulder instability. The questionnaire includes items related to physical symptoms, sports and work function, lifestyle, and emotional well-being. Total scores range from 0 to 2100, with higher scores indicating greater impairment and poorer shoulder function.
At baseline, week 4, and week 8 after the intervention

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

9 novembre 2025

Achèvement primaire (Estimé)

15 juin 2026

Achèvement de l'étude (Estimé)

30 juillet 2026

Dates d'inscription aux études

Première soumission

3 mai 2026

Première soumission répondant aux critères de contrôle qualité

20 mai 2026

Première publication (Réel)

28 mai 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

28 mai 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

20 mai 2026

Dernière vérification

1 mars 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • 202501014RINA

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner