Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Implant Stability Outcomes Following Immediate Implant Placement Using Osseodensification Versus Conventional Drilling

19 juillet 2026 mis à jour par: Sally Abd-ElMeniem ElHaddad, Dar Al Uloom University

Clinical, Radiographic, and Implant Stability Outcomes Following Immediate Implant Placement Using Osseodensification Versus Conventional Drilling in Mandibular Molar Extraction Sockets: A Randomized Clinical Trial

The goal of this randomized clinical trial is to compare osseodensification and conventional drilling for immediate dental implant placement in mandibular molar extraction sockets in adults requiring extraction and implant replacement.

The main questions it aims to answer are:

Does osseodensification improve primary and secondary implant stability compared with conventional drilling? Does osseodensification result in better clinical and radiographic peri-implant outcomes, including marginal bone loss, peri-implant bone density, probing depth, plaque and bleeding indices, during the healing period?

Researchers will compare immediate implant placement performed using osseodensification drilling with immediate implant placement performed using conventional drilling to determine whether osseodensification provides superior implant stability and peri-implant tissue outcomes.

Participants will:

Undergo atraumatic extraction of a mandibular molar followed by immediate implant placement.

Be randomly assigned to receive implant site preparation using either osseodensification or conventional drilling.

Receive the same implant system and standardized surgical and prosthetic protocols.

Attend scheduled follow-up visits for clinical examinations, implant stability measurements using resonance frequency analysis (ISQ), and radiographic evaluation of marginal bone loss and peri-implant bone density during healing and after prosthetic restoration.

Aperçu de l'étude

Description détaillée

Immediate implant placement into fresh extraction sockets has become a well-established treatment approach because it reduces treatment time, decreases the number of surgical procedures, and helps preserve hard and soft tissue architecture. Nevertheless, obtaining adequate primary implant stability in fresh mandibular molar extraction sockets remains a major clinical challenge because of socket morphology, limited interradicular bone, and variations in bone density.

Osseodensification is a non-subtractive osteotomy preparation technique that uses specially designed burs rotating in a densifying mode to preserve and compact bone around the implant osteotomy. Unlike conventional drilling, which removes bone during osteotomy preparation, osseodensification compacts autogenous bone along the osteotomy walls, potentially increasing bone density, bone-to-implant contact, and primary implant stability while promoting favorable healing.

Although promising results have been reported for osseodensification, clinical evidence directly comparing this technique with conventional drilling during immediate implant placement in mandibular molar extraction sockets remains limited. This randomized clinical trial was designed to evaluate whether osseodensification provides superior clinical, radiographic, and implant stability outcomes compared with conventional drilling.

Eligible participants requiring extraction of a mandibular molar followed by immediate implant placement were randomly allocated to one of two treatment groups:

Osseodensification group: implant osteotomy prepared using the osseodensification drilling protocol.

Conventional drilling group: implant osteotomy prepared using the manufacturer's conventional drilling sequence.

All participants underwent atraumatic tooth extraction, immediate implant placement using the same implant system, grafting of the peri-implant gap when indicated according to the study protocol, customized healing abutment placement, and standardized prosthetic rehabilitation after the healing period. Postoperative care and follow-up schedules were standardized for both groups.

Clinical evaluations included assessment of the modified plaque index, modified bleeding index, and peri-implant probing depth. Implant stability was assessed using resonance frequency analysis and expressed as the Implant Stability Quotient (ISQ). Radiographic assessments included measurements of marginal bone loss using standardized periapical radiographs and peri-implant bone density using cone-beam computed tomography (CBCT). Participants were followed according to the study schedule to evaluate implant stability, peri-implant tissue health, and radiographic bone changes during healing and after functional restoration.

The primary objective of the trial was to compare primary and secondary implant stability between osseodensification and conventional drilling. Secondary objectives included comparison of peri-implant clinical parameters, marginal bone loss, and peri-implant bone density between the two treatment groups.

Type d'étude

Interventionnel

Inscription (Estimé)

20

Phase

  • N'est pas applicable

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

      • Riyadh, Arabie Saoudite, 11512
        • Dar AlUloom University, College of Dentistry

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

  • Adulte

Accepte les volontaires sains

Oui

La description

Inclusion Criteria:

Adults aged 20 years - 50 years. Patients requiring extraction of a mandibular first or second molar with immediate implant placement.

Presence of sufficient interradicular and apical bone to achieve primary implant stability following immediate implant placement.

Adequate bone dimensions to accommodate the planned dental implant without the need for extensive bone augmentation.

Good oral hygiene and willingness to comply with the study protocol and follow-up visits.

Ability to understand the study procedures and provide written informed consent.

-

Exclusion Criteria:

Uncontrolled systemic diseases or medical conditions contraindicating oral surgery or implant placement.

Pregnancy or lactation. Current smokers or tobacco users. Untreated active periodontal disease or poor oral hygiene. Acute infection or extensive pathology at the implant site that would preclude immediate implant placement.

History of radiotherapy to the head and neck region or treatment with intravenous bisphosphonates or other medications known to adversely affect bone healing.

Bruxism or parafunctional habits likely to compromise implant success. Inability or unwillingness to attend scheduled follow-up visits or comply with study requirements.

-

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Randomisé
  • Modèle interventionnel: Affectation parallèle
  • Masquage: Aucun (étiquette ouverte)

Armes et Interventions

Groupe de participants / Bras
Intervention / Traitement
Expérimental: osseodensification drilling group
Immediate implant placement using osseodensification drilling for implant osteotomy preparation.
Implant osteotomy preparation was performed using the osseodensification drilling protocol with densifying burs rotating in densifying mode before immediate implant placement in mandibular molar extraction sockets.
Comparateur actif: conventional drilling protocol
Immediate implant placement using the conventional drilling protocol for implant osteotomy preparation.
Implant osteotomy preparation was performed using the conventional sequential drilling protocol before immediate implant placement in mandibular molar extraction

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Primary Implant Stability
Délai: Day 0, and 3 months

Implant stability, measured by the Implant Stability Quotient (ISQ) using resonance frequency analysis (RFA), assessed immediately after implant placement (primary stability) and during the follow-up period (at 3 months) to evaluate secondary stability.

Implant stability will be assessed using resonance frequency analysis (RFA) with the Osstell® device. Stability will be expressed as the Implant Stability Quotient (ISQ), a unitless index ranging from 1 to 100, where higher ISQ values indicate greater implant stability. Measurements will be obtained by attaching a SmartPeg to the implant and recording ISQ values in two perpendicular directions (buccolingual and mesiodistal). The mean of the two measurements will be used for statistical analysis. Implant stability will be evaluated immediately after implant placement (baseline/primary stability), and at 3 months and 6 months postoperatively (secondary stability). The primary outcome will be the difference in mean ISQ values between the

Day 0, and 3 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Secondary Implant Stability
Délai: 3 months after implant placement
Secondary implant stability assessed using resonance frequency analysis (RFA) and expressed as the Implant Stability Quotient (ISQ).
3 months after implant placement
Marginal Bone Loss (MBL)
Délai: Baseline, 3 months, and 6 months after implant placement
Marginal bone loss measured on standardized digital periapical radiographs as the distance from the implant reference point to the first bone-to-implant contact on the mesial and distal aspects.
Baseline, 3 months, and 6 months after implant placement
Peri-implant Bone Density
Délai: Baseline, 3 months, and 6 months after implant placement
Bone density surrounding the implant measured using cone-beam computed tomography (CBCT) and expressed in Hounsfield Units (HU).
Baseline, 3 months, and 6 months after implant placement
Peri-implant Probing Depth (PPD)
Délai: 3 months and 6 months after implant placement
Peri-implant probing depth measured in millimeters at four sites around each implant using a periodontal probe.
3 months and 6 months after implant placement
Modified Plaque Index (mPI)
Délai: Baseline, 3 months, and 6 months after implant placement
Plaque accumulation around implants assessed using the Modified Plaque Index.
Baseline, 3 months, and 6 months after implant placement
Modified Bleeding Index (mBI)
Délai: Baseline, 3 months, and 6 months after implant placement
Peri-implant soft tissue inflammation assessed using the Modified Bleeding Index.
Baseline, 3 months, and 6 months after implant placement

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

20 décembre 2025

Achèvement primaire (Estimé)

15 septembre 2026

Achèvement de l'étude (Estimé)

30 septembre 2026

Dates d'inscription aux études

Première soumission

7 juillet 2026

Première soumission répondant aux critères de contrôle qualité

19 juillet 2026

Première publication (Réel)

22 juillet 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

22 juillet 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

19 juillet 2026

Dernière vérification

1 juillet 2026

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • # 37-03-2025

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

NON

Description du régime IPD

Individual participant data will not be shared due to institutional and ethical restrictions regarding participant confidentiality.

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner