Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

A Clinical Study to Collect Real-wordt Data on Safety and Clinical Performance of the VCFix Spinal System for Treatment of Vertebral Compression Fractures of (Suspected) Osteoporotic Origin. (EXPAND-US)

4 novembre 2026 mis à jour par: Amber Implants B.V.

A Prospective, Multicenter, Post-Market Clinical Study Collecting Real-World Data of the VCFix Spinal System in Stand-Alone Configuration for Vertebral Augmentation (EXPAND-US)

This study is designed as a prospective, post-market, multi-center, single-arm study to collect real-world data of the VCFix Spinal System used in US clinical practice.

Approximately 5 centers in the US will enroll subjects with VCF in a non-randomized fashion, and VCFix will be used within its cleared purpose and indications for use.

The study has been designed to be methodologically compatible with the EU EXPAND (CIP-VS02-EU) study, thereby aiming for the pooling of data to the EU study. Data pooling will be pursued only as a sensitivity analysis if pre-specified similarity criteria are met. The US study provides meaningful real-world evidence regardless of pooling feasibility.

The targeted patient population, assessment schedule, and study endpoints are therefore similar to those of the EU EXPAND study.

Aperçu de l'étude

Type d'étude

Observationnel

Inscription (Estimé)

30

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Coordonnées de l'étude

Lieux d'étude

    • New York
      • New York, New York, États-Unis, 10467
        • Recrutement
        • Montefiore Medical Center
        • Contact:
          • Research Administrator
          • Numéro de téléphone: (718) 920-6202
    • Oklahoma
      • Oklahoma City, Oklahoma, États-Unis, 73104
        • Pas encore de recrutement
        • University of Oklahoma Health Campus
        • Contact:
          • Research Project Manager
          • Numéro de téléphone: (405) 271-8001
    • Pennsylvania
      • Philadelphia, Pennsylvania, États-Unis, 19107
        • Pas encore de recrutement
        • Rothman Orthopaedics
        • Contact:
          • Clinical Research Coordinator
          • Numéro de téléphone: (484) 335-2910

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

21 ans à 85 ans (Adulte, Adulte plus âgé)

Accepte les volontaires sains

Non

Sexes éligibles pour l'étude

Tout

Méthode d'échantillonnage

Échantillon non probabiliste

Population étudiée

Adult patients undergoing treatment with the VCFix Spinal System as part of standard clinical care for vertebral compression fractures. The study will enroll patients treated according to routine clinical practice and will collect real-world evidence on clinical outcomes, radiographic outcomes, and patient-reported outcomes following treatment.

La description

Inclusion Criteria:

  • 1. Subject is ≥ 21 to ≤ 85 years old. 2.

Single vertebral fracture which meets all of the following criteria:

  • Type A fractures from AO spine classification (compression injuries);
  • Vertebral fracture located in the thoracic and lumbar regions of the spine
  • Fracture age < 6 weeks or fractures with anatomic signs of reducibility (based on radiographic evidence as well as patient history)
  • Vertebral fracture shows an estimated height loss in the anterior or mid third of the vertebral body (VB) of at least 10% but not more than 60% based on radiographic evidence
  • Target VB has appropriate anatomy, i.e. suitable pedicle diameter, pedicle length and chord length that would allow for selection of correct implant size, as described in the IFU and based on axial MRI/CT scan before surgery 3. Subject is diagnosed with, or has a suspected diagnosis of, severe osteoporosis, including low trabecular bone quality , and/or an oversized vertebral body as compared to implant size (e.g. relatively small pedicle requiring smaller implant size than desired for vertebral body size and/or fracture characteristics and location) 4. Subject has a NPRS back pain score of ≥5 5. Subject is a candidate for surgical intervention based on investigator opinion 6. Subject has a body Mass Index (BMI) < 35 7. Subject is mentally capable of complying with trial protocol requirements for the duration of the study 8. Subject can understand the risks and benefits of participating in the study and is able to provide written informed consent

Exclusion Criteria:

  1. Neoplasms with posterior involvement and/or presence of a mass within the spinal canal

  2. Non-mobile fractures (i.e., fracture is not recent (>6 weeks), bone marrow edema or fluid or empty cleft are not visible in radiographic imaging, or fracture mode does not allow for fracture reduction in craniocaudal direction).

  3. Spondylolisthesis > Grade 1 at target vertebral body(s)

  4. Local kyphotic angle > 30°

  5. Any pre-existing vertebral fracture prior to the index fracture

  6. Previous spine surgery, balloon kyphoplasty or vertebroplasty, for any vertebral fracture

  7. Subjects that require anterior stabilization of the index fracture

  8. Fracture to the pedicle based on radiographic evaluation

  9. Spinal cord compression or canal compromise requiring decompression

  10. Severe back pain due to causes other than acute fracture with NPRS score > 5

  11. The subject has pain based on clinical diagnosis of herniated nucleus pulposus or severe spinal stenosis (progressive weakness or paralysis)

  12. Pain due to any other condition that requires daily narcotic (opiates or opioids) medication

  13. Pre-existing neurological deficit, radiculopathy or myelopathy

  14. Pre-existing condition or significant co-morbidity:

    1. Uncontrolled diabetes (HbA1c >8%)
    2. Severe cardiopulmonary deficiencies
    3. Any other condition that would impact study outcome in the opinion of the investigator
  15. Irreversible coagulopathy or bleeding disorder

  16. Contraindications to both MRI and Computed Tomography (CT) imaging

  17. Concurrent participation in another clinical study which could potentially interfere with the outcome of this study

  18. A life expectancy less than the study duration or undergoing palliative care

  19. Subject non-ambulatory prior to fracture Allergy to any components of the device/instruments used during the procedure

  20. Allergy to any components of the device/instruments used during the procedure

  21. Active or incompletely treated infection of the vertebral column or active systemic infection, including unresolved urinary tract infection

  22. Any underlying systemic bone disease other than osteoporosis (e.g., osteomalacia, osteogenesis imperfecta, Paget's disease, etc.)

  23. Any evidence of alcohol or drug abuse

  24. Ongoing long-term steroid therapy (steroid dose ≥30 mg /day for >3 months)

  25. The subject is currently on anti-cancer therapy or anti-HIV therapy

  26. Pregnancy or subjects with child-bearing potential that are unwilling to use contraception throughout the study duration.

  27. Patient known to be involved in medical litigation including Workmen's Compensation prior to the surgery

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Modèles d'observation: COHORT
  • Perspectives temporelles: PROSPECTIVE

Cohortes et interventions

Groupe / Cohorte
Intervention / Traitement
Implant of the VCFix device per IFU

Patients with a (suspected) diagnosis of severe osteoporosis and a single vertebral compression fracture

The distinguishing features of this inetrvention reside in: 1. In situ adjustment and maintenance of the height and angle of the device that allows expansion of the fractured VB in the cranio-caudal direction to realign the vertebral endplates and correct kyphosis. 2. The complex titanium perforated structure with optimized surface roughness that allows possible bone attachment, thereby permitting natural healing of the bone and potentially providing more stability to the device and the treated vertebra over time. 3. The ability to connect the posterior to the anterior column of the spine through the pedicle screw component of the VCFix implant, therefore improving the biomechanical load distribution and consequently the ability to stabilize more severe fractures.

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Description de la mesure
Délai
Incidence of serious adverse events (SAEs) related to the device and/or investigational procedure (safety)
Délai: 1 month

Incidence of serious adverse events (SAEs) related to the device and/or investigational procedure within 30 days post-procedure. This includes SAEs resulting from mechanical malfunction, structural compromise, device failure, or loss of intended function, as well as events representing deviations from the device's intended medical purpose.

1 month
Vertebral fracture-related pain as assessed by the Numeric Pain Rating Scale (NPRS)
Délai: 6 months

Difference in vertebral fracture-related pain from baseline 6 months post procedure measured by the 11-point (0 = no pain, 10 is worst pain) Numerical Pain Rating Scale (NPRS).

6 months
Functional disability, measured by the Oswestry disability index (ODI)
Délai: 6 months

Difference in functional disability, measured by the Oswestry disability index (ODI) (0-100 scale, where 0 is no disability and 100 is bed bound), from baseline to 6 months post procedure.

6 months

Mesures de résultats secondaires

Mesure des résultats
Description de la mesure
Délai
Vertebral height difference (anterior, midline, and posterior aspects)
Délai: Post-Operative, 1Month FU, 6 Months FU, 12 Months FU

Vertebral height difference (anterior, midline, and posterior aspects) at PO (Post-OP), 1M FU, 6M FU and 12M FU as compared to baseline.

Post-Operative, 1Month FU, 6 Months FU, 12 Months FU
Kyphotic angle and Cobb angle improvement at Post-Operative, 1 Month FU, 6 Months FU and 12 Months FU.
Délai: Post-Operative, 1 Month FU, 6 Months FU and 12 Months FU.

Kyphotic angle and Cobb angle improvement

Post-Operative, 1 Month FU, 6 Months FU and 12 Months FU.
Vertebral fracture-related pain as assessed by the Numeric Pain Rating Scale (NPRS)
Délai: Discharge, 1, 3, 6 and 12 Months FU compared to baseline.

Difference in vertebral fracture-related pain from baseline to Discharge, 1, 3, 6 and 12 Months post procedure measured by the 11-point (0 = no pain, 10 is worst pain) Numerical Pain Rating Scale (NPRS).

Discharge, 1, 3, 6 and 12 Months FU compared to baseline.
Functional disability, measured by the Oswestry disability index (ODI)
Délai: Discharge, 1, 3, 6 and 12 months FU

Improvement in function (measured by the 100-point Oswestry Disability Index (ODI)) at discharge, 1, 3, 6 and 12 months FU compared to baseline.

Discharge, 1, 3, 6 and 12 months FU
Health-related quality of life (HRQoL) measured by EuroQol 5-Dimension Scale (EQ-5D-5L) at 1 Month, 3 Months, 6 Months and 12 Months post-procedure compared to baseline
Délai: 1 Month, 3 Months, 6 Months and 12 Months post-procedure compared to baseline

Improvement of Health-related quality of life (HRQoL)

1 Month, 3 Months, 6 Months and 12 Months post-procedure compared to baseline
Device-related serious adverse events assessed at 12- and 24- months post-procedure.
Délai: 12 months FU, 24 months FU

Device-related serious adverse events

12 months FU, 24 months FU
All (per protocol reportable) adverse events assessed at 12- and 24- months post-procedure.
Délai: 12 Months FU, 24 Months FU

All (per protocol reportable) adverse events assessed at 12- and 24- months post-procedure.

12 Months FU, 24 Months FU

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude (Réel)

4 octobre 2026

Achèvement primaire (Estimé)

21 juillet 2027

Achèvement de l'étude (Estimé)

31 décembre 2028

Dates d'inscription aux études

Première soumission

31 juillet 2026

Première soumission répondant aux critères de contrôle qualité

4 novembre 2026

Première publication (Réel)

5 novembre 2026

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Réel)

5 novembre 2026

Dernière mise à jour soumise répondant aux critères de contrôle qualité

4 novembre 2026

Dernière vérification

1 novembre 2026

Plus d'information

Termes liés à cette étude

Plan pour les données individuelles des participants (IPD)

Prévoyez-vous de partager les données individuelles des participants (DPI) ?

INDÉCIS

Informations sur les médicaments et les dispositifs, documents d'étude

Étudie un produit pharmaceutique réglementé par la FDA américaine

Non

Étudie un produit d'appareil réglementé par la FDA américaine

Oui

produit fabriqué et exporté des États-Unis.

Non

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .

S'abonner