- ICH GCP
- Registre américain des essais cliniques
- Essai clinique NCT07961395
Comparison of Two Recovery Drinks (InnoX)
Comparison of Two Recovery Drinks on Recovery of Endurance and Jump Performance
Recovery drinks are commonly used to support recovery between training sessions, but the effects of different carbohydrate sources on short-term performance recovery remain unclear. This study compared a newly developed recovery drink containing a glucose-galactose carbohydrate blend (Product 1) with a commercially available recovery drink containing primarily maltodextrin (Product 2). The aim was to evaluate their effectiveness in supporting recovery of endurance performance and neuromuscular function during a short recovery period.
Briefly, fourteen physically active adults (7 women, mean ± SD age 33 ± 6 years) completed a randomized crossover study. On two separate visits, within a 2-month period, participants performed countermovement jump testing and an incremental cycling test to exhaustion, followed by 1 hour of cycling at 50% of maximal power output. After exercise, participants consumed either Product 1 or Product 2 in randomized order. After a 2-hour recovery period, the jump and cycling tests were repeated.
Aperçu de l'étude
Statut
Les conditions
Type d'étude
Inscription (Réel)
Phase
- N'est pas applicable
Contacts et emplacements
Lieux d'étude
-
-
-
Turku, Finlande, 20520
- University of Turku
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
Accepte les volontaires sains
Sexes éligibles pour l'étude
La description
Inclusion Criteria:
- age between 18-45 years, being physically active or an athlete
Exclusion Criteria:
- milk allergy or lactose intolerance, poor health status (recent infections or other illnesses)
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
- Objectif principal: Science basique
- Répartition: Randomisé
- Modèle interventionnel: Affectation croisée
- Masquage: Double
Armes et Interventions
Groupe de participants / Bras |
Intervention / Traitement |
|---|---|
|
Expérimental: Group A; first Product 1, then Product 2
Participants completed two study visits in a randomized crossover design. At visit 1, Group A (half of the participants) consumed Product 1, a recovery drink containing a glucose-galactose carbohydrate blend (50 g powder mixed with 400 mL water), following a standardized exercise protocol. At visit 2, the same participants (Group A) consumed Product 2, a commercially available recovery drink containing primarily maltodextrin (50 g powder mixed with 400 mL water), following the same exercise protocol as at visit 1. |
Product 1 is a newly developed recovery drink containing a glucose-galactose carbohydrate blend (50 g powder mixed with 400 mL water). Product 2 is a commercially available recovery drink containing primarily maltodextrin (50 g powder mixed with 400 mL water). |
|
Expérimental: Group B; first Product 2, then Product 1
Participants completed two study visits in a randomized crossover design. At visit 1, Group B (half of the participants) consumed Product 2, a commercially available recovery drink containing primarily maltodextrin (50 g powder mixed with 400 mL water), following a standardized exercise protocol. At visit 2, the same participants (Group B) consumed Product 1, a recovery drink containing a glucose-galactose carbohydrate blend (50 g powder mixed with 400 mL water), following the same exercise protocol as at visit 1. |
Product 1 is a newly developed recovery drink containing a glucose-galactose carbohydrate blend (50 g powder mixed with 400 mL water). Product 2 is a commercially available recovery drink containing primarily maltodextrin (50 g powder mixed with 400 mL water). |
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
2-minute maximal power output; an incremental cycling test to exhaustion (Ergoline Ergoselect 100, Ergoline GmbH, Bitz, Germany)
Délai: 8 weeks
|
Men began the test with 50 W and resistance was increased 30 W every two minutes. Women began the test with 40 W resistance and resistance increased 20 W every two minutes. Subjects were instructed to keep the pedaling cadence between 70 and 100 rounds per minute (rpm), and the test ended when the cadence dropped below 70 rpm. |
8 weeks
|
|
VO₂peak; an incremental cycling test to exhaustion (Ergoline Ergoselect 100, Ergoline GmbH, Bitz, Germany) with respiratory gases measured using breath-by-breath respiratory gas analyzer (Vyntus CPX, Vyaire Medical GmbH, Höchberg, Germany)
Délai: 8 weeks
|
Men began the test with 50 W and resistance was increased 30 W every two minutes. Women began the test with 40 W resistance and resistance increased 20 W every two minutes. Subjects were instructed to keep the pedaling cadence between 70 and 100 rounds per minute (rpm), and the test ended when the cadence dropped below 70 rpm. |
8 weeks
|
|
Countermovement jump height; five countermovement jumps on a light mat (Microgate Optojump, Microgate Srl, Bolzano, Italy) of which the average of three best jumps was used as a result
Délai: 8 weeks
|
8 weeks
|
Collaborateurs et enquêteurs
Parrainer
Collaborateurs
Publications et liens utiles
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Réel)
Achèvement primaire (Réel)
Achèvement de l'étude (Réel)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Termes MeSH pertinents supplémentaires
Autres numéros d'identification d'étude
- TY/653/2025
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .