このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Comparing Palpation Guided and Ultrasound Guided Arterial Line Placement

2016年9月27日 更新者:Rutgers, The State University of New Jersey

A Prospective Study Comparing Palpation Guided and Ultrasound Guided Arterial Catheter Placement by Anesthesiology Residents in Training

When surgery is performed under general anesthesia, a catheter is placed in a vein to administer drugs and saline. During major operations, an additional catheter is placed in an artery in order to measure the blood pressure closely and withdraw blood samples at frequent intervals for various laboratory tests. This arterial catheter is usually placed by feeling the patient's artery at the wrist and inserting the guide-needle in a blind fashion. This procedure, at times, leads to delays and failures due to an inability to feel the arterial pulsation well either due to the patients' anatomy or the anesthetic effect. This study will determine whether training Anesthesiology Residents in the use of ultrasound technology and its application in identifying an artery can prevent the problems associated with the conventional palpation technique. Our finding will lead to better and safer anesthetic management of patients presenting for a major surgical procedure. Furthermore, the finding will help us in introducing the education and training of ultrasound-guided arterial catheter placement in our Residency Program.

The investigators propose to follow anesthesia residents over a course of 3 years assessing their skill level for both palpation and ultrasound technique.

調査の概要

詳細な説明

This is an updated study on a previous IRB-approved research (0120070296) which was terminated prior to conclusion as the principal investigator terminated his employment at the UNDNJ. An arterial catheter is routinely placed immediately following induction of anesthesia, in major operative procedures, in order to measure blood pressure continuously, perform frequent blood-gas analysis and withdraw blood for repeated laboratory testing. The arterial catheter is traditionally placed blindly by palpating the radial artery of the patient. This way of placing a radial artery catheter can encounter delay or failure due to conditions such as obesity, arteriosclerosis, arterial spasm and anesthesia-induced hypotension. Our study will compare the performance of Anesthesiology Residents in placing an arterial catheter by the traditional palpation-guided technique and by the ultrasound-guided technique after training in ultrasound usage. The comparison will utilize the following parameters:

  • Time taken to successfully place a catheter
  • Number of attempts needed to place a catheter
  • Number of puncture site changes encountered
  • Failure rate of the resident with each technique
  • The need for replacement of the catheter during surgery The data collection will be done by an independent observer, who is not a member of the anesthesia care team or research team. The Residents performing the catheter placement will not be members of the research team and will not have access to the data. If the Resident fails to place the catheter, the attending anesthesiologist will rescue by placing the arterial catheter himself by a method of his choice. In the previous study, there was a trend toward a reduced failure rate and a decreased time for insertion with the ultrasound technique. In this study, the investigators will introduce the research to the first-year Residents and repeat the exercise during their second and third year of training in a longitudinal fashion to assess the progress during anesthesia training. The investigators plan to enroll eight residents from the first-year class. Each resident will perform eight arterial catheter placements with each technique. In addition, compared to the previous study, a more advanced ultrasound machine will be used which will provide better visualization of the radial artery.

研究の種類

観察的

入学 (実際)

4

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • New Jersey
      • Newark、New Jersey、アメリカ、07101
        • University Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

25年~35年 (大人)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

確率サンプル

調査対象母集団

CA 1 and CA 2 residents assigned to surgical patients who require arterial lines due to complex surgical procedures

説明

Inclusion Criteria:

  • resident in training is agreeable to consent

Exclusion Criteria:

  • None

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
CA 1 and 2 anethesia residents
palpation technique
placement of a line via palpation technique
Ca1 and 2 residents
ultrasound guided technique
instruction in the ultrasound technique

この研究は何を測定していますか?

主要な結果の測定

結果測定
時間枠
time to successful placement of catheter
時間枠:residents to be timed over 2 years
residents to be timed over 2 years

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始

2012年10月1日

一次修了 (実際)

2015年6月1日

研究の完了 (実際)

2015年6月1日

試験登録日

最初に提出

2012年9月27日

QC基準を満たした最初の提出物

2012年12月20日

最初の投稿 (見積もり)

2012年12月28日

学習記録の更新

投稿された最後の更新 (見積もり)

2016年9月28日

QC基準を満たした最後の更新が送信されました

2016年9月27日

最終確認日

2015年9月1日

詳しくは

本研究に関する用語

キーワード

その他の研究ID番号

  • 2012001193

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する