Conventional Alignment System Versus Surgical Navigation System in Total Knee Arthroplasty

2017年7月10日 更新者:Hospital for Special Surgery, New York

Conventional Tibial Extramedullary Alignment System Versus a Hand-Held, Surgical Navigation System for Tibial Component Placement in Total Knee Arthroplasty: A Randomized, Controlled Trial

This is a randomized, controlled, blinded prospective study comparing the use of the usual cutting guides with a palm-sized digital surgical navigation system in unilateral total knee arthroplasty. Analysis of pre- and post-operative X-rays will be used to compare alignment of the tibial (shinbone) implant components. The investigators expect that the FDA-approved hand-held surgical navigation device will increase the accuracy and precision of the tibial cut by telling the surgeon the exact position of the cutting block before the surgeon makes the cut, allowing minor adjustments to be made. The investigators expect the conventional device to take less time to use, but that this difference will decrease as the surgeon becomes more familiar with the device. The investigators expect the intraoperative measurements acquired by the KneeAlign system to strongly correlate with the radiographic alignments measured postoperatively.

調査の概要

詳細な説明

Medical records, private office charts, and electronic medical records will be utilized by the co-investigators to review data on patients who fit the previously stated inclusion criteria. Demographic data including age, gender, height (cm), and weight (kg) will be collected. Preoperative, standing anteroposterior hip-to-ankle radiographs will be measured for the lower extremity mechanical axis, the tibiofemoral anatomic alignment, and the distal femoral and proximal tibial anatomic angles. Intraoperative time measurements for use of both the conventional extramedullary alignment guide, and the KneeAlignTM system will be measured and recorded. The time required to utilize each alignment guide will be measured in seconds, starting from the time at which the surgeon is handed the alignment guide (KneeAlignTM or conventional, extramedullary), to the time at which the surgeon is handed the oscillating saw to make the tibial cut. Of note, no intraoperative alignment measurements are required or will be recorded for the conventional, extramedullary systems, while intraoperative alignments reported by the KneeAlignTM system will be recorded when the KneeAlignTM device is used. In addition, regarding the use of conventional, extramedullary tibial guides, each surgeon will utilize the guide (regardless of manufacturer) which they currently use most frequently when performing a total knee arthroplasty. While there may be minimal differences with regards each of the surgeon's conventional guides, they are all essentially the same with regards to utilizing an extramedullary rod for alignment of the tibial resection.

Currently, a total knee replacement requires an average tourniquet time of 30-50 minutes depending on the surgeon. We estimate an approximate increase in total tourniquet time of 5-6 minutes when using the hand-held surgical navigation system.

For each procedure (either KneeAlignTM or conventional, extramedullary guides), after making the initial cut, if at any point in the procedure the surgeon re-cuts the tibia, they will be asked a series of questions postoperatively as to why they re-cut the tibia as part of the data collection. These questions will include:

  1. Did you re-cut the tibia because you thought more varus or valgus was required?
  2. Did you re-cut the tibia to increase or decrease the posterior slope?
  3. Did you re-cut the tibia to increase the amount of bone resected?
  4. Were you happy with the overall tibial alignment? Postoperative radiographs will be obtained as part of each surgeon's postoperative protocol, and will include a standing anteroposterior hip-to-ankle radiograph and a standing lateral knee-to-ankle radiograph, from which the lower extremity mechanical axis, the tibiofemoral anatomic alignment, the tibial component mechanical alignment, and the tibial component posterior slope will be measured.

This study has the potential to provide significant information regarding the clinical accuracy and precision of the KneeAlignTM system compared to that of conventional, extramedullary alignment systems. If mechanical and tibial mechanical alignment is significantly improved with the use of the KneeAlignTM system, this may encourage surgeons to utilize this device to improve postoperative alignment in total knee arthroplasty. In addition, surgeon's may find this type of hand-held system more user-friendly (in contrast to a large console, computer-assisted surgical system), and this may stimulate future investigations into similar devices for femoral component alignment, and also total hip arthroplasty.

研究の種類

介入

入学 (実際)

100

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • New York
      • New York、New York、アメリカ、10021
        • Hospital for Special Surgery

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

説明

Inclusion Criteria:

  • a history of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis
  • patients who have been indicated for a primary, posterior-stabilized, total knee arthroplasty
  • patients have had a preoperative standing anteroposterior hip-to-ankle radiograph and standing lateral knee-to-ankle radiographs

Exclusion Criteria:

  • patients with proximal tibial defects requiring either a metal or allograft augment
  • inadequate radiographic studies as required by the study protocol
  • if they do not receive a total knee arthroplasty, or receive a unicondylar arthroplasty

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:トリプル

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:Conventional System
Conventional tibial extramedullary alignment system used by surgeon during surgery.
This is the standard of care for total knee arthroplasty.
実験的:KneeAlign System
Digital hand-held surgical navigation system for tibial component placement used by surgeon during surgery.
Digital hand-held surgical navigation system used for tibial component placement in total knee arthroplasty
他の名前:
  • KneeAlign
  • OrthAlign

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Postoperative Tibial Component Alignment
時間枠:6 weeks after surgery
The primary outcome will be the number of patients (percentage of patients) that met a predetermined criteria for Alignment as defined by within 2° of perpendicular to the tibial mechanical axis or 2° of a 3° posterior slope, postoperative tibial component alignment (mechanical varus/valgus, and posterior slope) as measured on postoperative standing anteroposterior hip-to-ankle radiographs, and standing, lateral knee-to-ankle radiographs, respectively.
6 weeks after surgery

二次結果の測定

結果測定
メジャーの説明
時間枠
Time Required to Utilize System
時間枠:Minutes during surgery ( Estimated time per surgery 1 hour)
The amount of time required to utilize conventional, tibial extramedullary alignment guides versus the KneeAlignTM system, which will be recorded intraoperatively.
Minutes during surgery ( Estimated time per surgery 1 hour)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

捜査官

  • 主任研究者:David Mayman, MD、Hospital for Special Surgery, New York

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2010年12月1日

一次修了 (実際)

2013年3月1日

研究の完了 (実際)

2013年9月16日

試験登録日

最初に提出

2013年2月7日

QC基準を満たした最初の提出物

2013年2月21日

最初の投稿 (見積もり)

2013年2月22日

学習記録の更新

投稿された最後の更新 (実際)

2017年7月11日

QC基準を満たした最後の更新が送信されました

2017年7月10日

最終確認日

2017年7月1日

詳しくは

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する