- ICH GCP
- Registro de ensayos clínicos de EE. UU.
- Ensayo clínico NCT01797731
Conventional Alignment System Versus Surgical Navigation System in Total Knee Arthroplasty
Conventional Tibial Extramedullary Alignment System Versus a Hand-Held, Surgical Navigation System for Tibial Component Placement in Total Knee Arthroplasty: A Randomized, Controlled Trial
Descripción general del estudio
Estado
Condiciones
Descripción detallada
Medical records, private office charts, and electronic medical records will be utilized by the co-investigators to review data on patients who fit the previously stated inclusion criteria. Demographic data including age, gender, height (cm), and weight (kg) will be collected. Preoperative, standing anteroposterior hip-to-ankle radiographs will be measured for the lower extremity mechanical axis, the tibiofemoral anatomic alignment, and the distal femoral and proximal tibial anatomic angles. Intraoperative time measurements for use of both the conventional extramedullary alignment guide, and the KneeAlignTM system will be measured and recorded. The time required to utilize each alignment guide will be measured in seconds, starting from the time at which the surgeon is handed the alignment guide (KneeAlignTM or conventional, extramedullary), to the time at which the surgeon is handed the oscillating saw to make the tibial cut. Of note, no intraoperative alignment measurements are required or will be recorded for the conventional, extramedullary systems, while intraoperative alignments reported by the KneeAlignTM system will be recorded when the KneeAlignTM device is used. In addition, regarding the use of conventional, extramedullary tibial guides, each surgeon will utilize the guide (regardless of manufacturer) which they currently use most frequently when performing a total knee arthroplasty. While there may be minimal differences with regards each of the surgeon's conventional guides, they are all essentially the same with regards to utilizing an extramedullary rod for alignment of the tibial resection.
Currently, a total knee replacement requires an average tourniquet time of 30-50 minutes depending on the surgeon. We estimate an approximate increase in total tourniquet time of 5-6 minutes when using the hand-held surgical navigation system.
For each procedure (either KneeAlignTM or conventional, extramedullary guides), after making the initial cut, if at any point in the procedure the surgeon re-cuts the tibia, they will be asked a series of questions postoperatively as to why they re-cut the tibia as part of the data collection. These questions will include:
- Did you re-cut the tibia because you thought more varus or valgus was required?
- Did you re-cut the tibia to increase or decrease the posterior slope?
- Did you re-cut the tibia to increase the amount of bone resected?
- Were you happy with the overall tibial alignment? Postoperative radiographs will be obtained as part of each surgeon's postoperative protocol, and will include a standing anteroposterior hip-to-ankle radiograph and a standing lateral knee-to-ankle radiograph, from which the lower extremity mechanical axis, the tibiofemoral anatomic alignment, the tibial component mechanical alignment, and the tibial component posterior slope will be measured.
This study has the potential to provide significant information regarding the clinical accuracy and precision of the KneeAlignTM system compared to that of conventional, extramedullary alignment systems. If mechanical and tibial mechanical alignment is significantly improved with the use of the KneeAlignTM system, this may encourage surgeons to utilize this device to improve postoperative alignment in total knee arthroplasty. In addition, surgeon's may find this type of hand-held system more user-friendly (in contrast to a large console, computer-assisted surgical system), and this may stimulate future investigations into similar devices for femoral component alignment, and also total hip arthroplasty.
Tipo de estudio
Inscripción (Actual)
Fase
- No aplica
Contactos y Ubicaciones
Ubicaciones de estudio
-
-
New York
-
New York, New York, Estados Unidos, 10021
- Hospital for Special Surgery
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Niño
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Géneros elegibles para el estudio
Descripción
Inclusion Criteria:
- a history of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis
- patients who have been indicated for a primary, posterior-stabilized, total knee arthroplasty
- patients have had a preoperative standing anteroposterior hip-to-ankle radiograph and standing lateral knee-to-ankle radiographs
Exclusion Criteria:
- patients with proximal tibial defects requiring either a metal or allograft augment
- inadequate radiographic studies as required by the study protocol
- if they do not receive a total knee arthroplasty, or receive a unicondylar arthroplasty
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
- Propósito principal: Tratamiento
- Asignación: Aleatorizado
- Modelo Intervencionista: Asignación paralela
- Enmascaramiento: Triple
Armas e Intervenciones
Grupo de participantes/brazo |
Intervención / Tratamiento |
---|---|
Comparador activo: Conventional System
Conventional tibial extramedullary alignment system used by surgeon during surgery.
|
This is the standard of care for total knee arthroplasty.
|
Experimental: KneeAlign System
Digital hand-held surgical navigation system for tibial component placement used by surgeon during surgery.
|
Digital hand-held surgical navigation system used for tibial component placement in total knee arthroplasty
Otros nombres:
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Postoperative Tibial Component Alignment
Periodo de tiempo: 6 weeks after surgery
|
The primary outcome will be the number of patients (percentage of patients) that met a predetermined criteria for Alignment as defined by within 2° of perpendicular to the tibial mechanical axis or 2° of a 3° posterior slope, postoperative tibial component alignment (mechanical varus/valgus, and posterior slope) as measured on postoperative standing anteroposterior hip-to-ankle radiographs, and standing, lateral knee-to-ankle radiographs, respectively.
|
6 weeks after surgery
|
Medidas de resultado secundarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
---|---|---|
Time Required to Utilize System
Periodo de tiempo: Minutes during surgery ( Estimated time per surgery 1 hour)
|
The amount of time required to utilize conventional, tibial extramedullary alignment guides versus the KneeAlignTM system, which will be recorded intraoperatively.
|
Minutes during surgery ( Estimated time per surgery 1 hour)
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Investigador principal: David Mayman, MD, Hospital for Special Surgery, New York
Publicaciones y enlaces útiles
Publicaciones Generales
- Nam D, Weeks KD, Reinhardt KR, Nawabi DH, Cross MB, Mayman DJ. Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results. J Arthroplasty. 2013 Feb;28(2):255-61. doi: 10.1016/j.arth.2012.04.023. Epub 2012 Jun 14.
- Nam D, Jerabek SA, Cross MB, Mayman DJ. Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty. Comput Aided Surg. 2012;17(4):205-10. doi: 10.3109/10929088.2012.689335. Epub 2012 Jun 8.
- Nam D, Nawabi DH, Cross MB, Heyse TJ, Mayman DJ. Accelerometer-based computer navigation for performing the distal femoral resection in total knee arthroplasty. J Arthroplasty. 2012 Oct;27(9):1717-22. doi: 10.1016/j.arth.2012.02.007. Epub 2012 Mar 21.
- Nam D, Dy CJ, Cross MB, Kang MN, Mayman DJ. Cadaveric results of an accelerometer based, extramedullary navigation system for the tibial resection in total knee arthroplasty. Knee. 2012 Oct;19(5):617-21. doi: 10.1016/j.knee.2011.09.008. Epub 2011 Oct 26.
- Nam D, Jerabek SA, Haughom B, Cross MB, Reinhardt KR, Mayman DJ. Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty. J Arthroplasty. 2011 Dec;26(8):1527-33. doi: 10.1016/j.arth.2011.01.012. Epub 2011 Mar 11.
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Actual)
Finalización del estudio (Actual)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Estimar)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Términos MeSH relevantes adicionales
Otros números de identificación del estudio
- 10137 (DAIDS ES)
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .