- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT01797731
Conventional Alignment System Versus Surgical Navigation System in Total Knee Arthroplasty
Conventional Tibial Extramedullary Alignment System Versus a Hand-Held, Surgical Navigation System for Tibial Component Placement in Total Knee Arthroplasty: A Randomized, Controlled Trial
Studieöversikt
Status
Betingelser
Detaljerad beskrivning
Medical records, private office charts, and electronic medical records will be utilized by the co-investigators to review data on patients who fit the previously stated inclusion criteria. Demographic data including age, gender, height (cm), and weight (kg) will be collected. Preoperative, standing anteroposterior hip-to-ankle radiographs will be measured for the lower extremity mechanical axis, the tibiofemoral anatomic alignment, and the distal femoral and proximal tibial anatomic angles. Intraoperative time measurements for use of both the conventional extramedullary alignment guide, and the KneeAlignTM system will be measured and recorded. The time required to utilize each alignment guide will be measured in seconds, starting from the time at which the surgeon is handed the alignment guide (KneeAlignTM or conventional, extramedullary), to the time at which the surgeon is handed the oscillating saw to make the tibial cut. Of note, no intraoperative alignment measurements are required or will be recorded for the conventional, extramedullary systems, while intraoperative alignments reported by the KneeAlignTM system will be recorded when the KneeAlignTM device is used. In addition, regarding the use of conventional, extramedullary tibial guides, each surgeon will utilize the guide (regardless of manufacturer) which they currently use most frequently when performing a total knee arthroplasty. While there may be minimal differences with regards each of the surgeon's conventional guides, they are all essentially the same with regards to utilizing an extramedullary rod for alignment of the tibial resection.
Currently, a total knee replacement requires an average tourniquet time of 30-50 minutes depending on the surgeon. We estimate an approximate increase in total tourniquet time of 5-6 minutes when using the hand-held surgical navigation system.
For each procedure (either KneeAlignTM or conventional, extramedullary guides), after making the initial cut, if at any point in the procedure the surgeon re-cuts the tibia, they will be asked a series of questions postoperatively as to why they re-cut the tibia as part of the data collection. These questions will include:
- Did you re-cut the tibia because you thought more varus or valgus was required?
- Did you re-cut the tibia to increase or decrease the posterior slope?
- Did you re-cut the tibia to increase the amount of bone resected?
- Were you happy with the overall tibial alignment? Postoperative radiographs will be obtained as part of each surgeon's postoperative protocol, and will include a standing anteroposterior hip-to-ankle radiograph and a standing lateral knee-to-ankle radiograph, from which the lower extremity mechanical axis, the tibiofemoral anatomic alignment, the tibial component mechanical alignment, and the tibial component posterior slope will be measured.
This study has the potential to provide significant information regarding the clinical accuracy and precision of the KneeAlignTM system compared to that of conventional, extramedullary alignment systems. If mechanical and tibial mechanical alignment is significantly improved with the use of the KneeAlignTM system, this may encourage surgeons to utilize this device to improve postoperative alignment in total knee arthroplasty. In addition, surgeon's may find this type of hand-held system more user-friendly (in contrast to a large console, computer-assisted surgical system), and this may stimulate future investigations into similar devices for femoral component alignment, and also total hip arthroplasty.
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
New York
-
New York, New York, Förenta staterna, 10021
- Hospital For Special Surgery
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
- Barn
- Vuxen
- Äldre vuxen
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- a history of osteoarthritis, rheumatoid arthritis, or post-traumatic arthritis
- patients who have been indicated for a primary, posterior-stabilized, total knee arthroplasty
- patients have had a preoperative standing anteroposterior hip-to-ankle radiograph and standing lateral knee-to-ankle radiographs
Exclusion Criteria:
- patients with proximal tibial defects requiring either a metal or allograft augment
- inadequate radiographic studies as required by the study protocol
- if they do not receive a total knee arthroplasty, or receive a unicondylar arthroplasty
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Trippel
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
---|---|
Aktiv komparator: Conventional System
Conventional tibial extramedullary alignment system used by surgeon during surgery.
|
This is the standard of care for total knee arthroplasty.
|
Experimentell: KneeAlign System
Digital hand-held surgical navigation system for tibial component placement used by surgeon during surgery.
|
Digital hand-held surgical navigation system used for tibial component placement in total knee arthroplasty
Andra namn:
|
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
---|---|---|
Postoperative Tibial Component Alignment
Tidsram: 6 weeks after surgery
|
The primary outcome will be the number of patients (percentage of patients) that met a predetermined criteria for Alignment as defined by within 2° of perpendicular to the tibial mechanical axis or 2° of a 3° posterior slope, postoperative tibial component alignment (mechanical varus/valgus, and posterior slope) as measured on postoperative standing anteroposterior hip-to-ankle radiographs, and standing, lateral knee-to-ankle radiographs, respectively.
|
6 weeks after surgery
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
---|---|---|
Time Required to Utilize System
Tidsram: Minutes during surgery ( Estimated time per surgery 1 hour)
|
The amount of time required to utilize conventional, tibial extramedullary alignment guides versus the KneeAlignTM system, which will be recorded intraoperatively.
|
Minutes during surgery ( Estimated time per surgery 1 hour)
|
Samarbetspartners och utredare
Utredare
- Huvudutredare: David Mayman, MD, Hospital for Special Surgery, New York
Publikationer och användbara länkar
Allmänna publikationer
- Nam D, Weeks KD, Reinhardt KR, Nawabi DH, Cross MB, Mayman DJ. Accelerometer-based, portable navigation vs imageless, large-console computer-assisted navigation in total knee arthroplasty: a comparison of radiographic results. J Arthroplasty. 2013 Feb;28(2):255-61. doi: 10.1016/j.arth.2012.04.023. Epub 2012 Jun 14.
- Nam D, Jerabek SA, Cross MB, Mayman DJ. Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty. Comput Aided Surg. 2012;17(4):205-10. doi: 10.3109/10929088.2012.689335. Epub 2012 Jun 8.
- Nam D, Nawabi DH, Cross MB, Heyse TJ, Mayman DJ. Accelerometer-based computer navigation for performing the distal femoral resection in total knee arthroplasty. J Arthroplasty. 2012 Oct;27(9):1717-22. doi: 10.1016/j.arth.2012.02.007. Epub 2012 Mar 21.
- Nam D, Dy CJ, Cross MB, Kang MN, Mayman DJ. Cadaveric results of an accelerometer based, extramedullary navigation system for the tibial resection in total knee arthroplasty. Knee. 2012 Oct;19(5):617-21. doi: 10.1016/j.knee.2011.09.008. Epub 2011 Oct 26.
- Nam D, Jerabek SA, Haughom B, Cross MB, Reinhardt KR, Mayman DJ. Radiographic analysis of a hand-held surgical navigation system for tibial resection in total knee arthroplasty. J Arthroplasty. 2011 Dec;26(8):1527-33. doi: 10.1016/j.arth.2011.01.012. Epub 2011 Mar 11.
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Faktisk)
Avslutad studie (Faktisk)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Uppskatta)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- 10137 (DAIDS ES)
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .
Kliniska prövningar på Artros, knä
-
Smith & Nephew, Inc.AvslutadJourney II BCS Total Knee SystemFörenta staterna, Belgien, Nya Zeeland
-
Smith & Nephew, Inc.Nor Consult, LLCAvslutadJourney II XR Total Knee SystemFörenta staterna
-
Smith & Nephew, Inc.Nor ConsultAvslutadJourney II CR Total Knee SystemFörenta staterna
-
Central DuPage HospitalAvslutadTotalt knäbyte | Ersättning, Total Knee | Artroplastik, knäplastikFörenta staterna
-
Bispebjerg HospitalRekryteringJumper's Knee | Patellar tendinopatiDanmark
-
Universidad Nacional de CórdobaAvslutadJumper's Knee | Patellar tendinitArgentina
-
University of VirginiaAvslutadArtros | Tibial Femoral Knee ArtrosFörenta staterna
-
Bispebjerg HospitalUniversity College Absalon; Danske FysioterapeuterAktiv, inte rekryterandeJumper's Knee | Patellar tendinopatiDanmark
-
Cairo UniversityAktiv, inte rekryterande
-
Bispebjerg HospitalRekryteringTendinopati | Jumper's KneeDanmark
Kliniska prövningar på Conventional tibial extramedullary alignment system
-
MedtronicNeuroAvslutadÖveraktiv blåsaFörenta staterna
-
MedtronicNeuroAktiv, inte rekryterandeÖveraktiv blåsaFörenta staterna
-
Ellipse Technologies, Inc.AvslutadArtros | Varus malalignment
-
MicroPort Orthopedics Inc.Rekrytering
-
Encore Medical, L.P.DJO IncorporatedAvslutadArtros | Traumatisk artrit | Degenerativ ledsjukdomFörenta staterna
-
Walter Reed National Military Medical CenterInternational Urogynecological Association (Grant); Section on Women's...OkändÖveraktiv blåsa | TrängningsinkontinensFörenta staterna
-
Duke UniversitySociety of Urodynamics and Female Pelvic Medicine & Urogenital ReconstructionAvslutadUrininkontinensFörenta staterna