Imaging and Plan Workflow in a Novel Low-Field Magnetic Resonance Imaging (MRI) Radiotherapy Device
A Pilot Study of Imaging and Plan Workflow in a Novel Low-Field Magnetic Resonance Imaging (MRI) Radiotherapy Device
調査の概要
詳細な説明
Recently, Viewray Inc (Cleveland, OH) has released the RenaissanceTM System 1000, which consists of the combination of an open, split solenoid 0.35 T MRI scanner that is equipped for parallel imaging with a 60Co gamma-ray radiation treatment unit. The MRI scanner is required to be a low field unit to allow for imaging with spatial integrity by limiting magnetic susceptibility artifacts due to the patient and to prevent significant perturbations of the dose distribution. The 0.35 T magnet is a variant of the Siemens MAGNETOM product used for intraoperative imaging.
A previous study of pilot imaging using this device without the 60Co sources was completed in 2012 (HRPO# 201105295). In this study, a total of 26 patients were imaged with the device. Fourteen of these patients also had onboard CT imaging (OB-CT) where the two sets of imaging and relative organs at risk (OARs) could be compared. Fifteen to 24 OARs were evaluated per anatomical site. In total, 221 OARs and 10 target structures were compared for visualization on MRI and OB-CT image sets by each physician. At least 2/3 physicians evaluated MRI as offering better visualization for 71% of structures, OB-CT offering better visualization for 10% of structures, and both offering equivalent visualization for 14% of structures. Physicians agreed unanimously for 74% and in majority for >99% of structures evaluated, respectively. For <1% of structures, no consensus was reached. Targets were better visualized on MRI in 4/10 cases, and were never better visualized on OB-CT images.
There were limitations to this prior study. The patients were not imaged in immobilization devices that are commonly used in radiation therapy. This precluded the creation of a mock radiation therapy plan using the device for these patients. Also, the device was not evaluated in the context of radiation therapy decision making, such as patient shifts, target localization and patient repositioning.
The purpose of this study is to evaluate the imaging and plan workflow for radiation therapy utilizing this novel device. For this protocol, only the MRI scanner of the machine will be utilized. The 60Co portion of the machine capable of radiation treatment administration will not be utilized, and there will be no experimental treatments or modifications to each patient's standard of care radiation treatment plan.
研究の種類
入学 (実際)
段階
- フェーズ 1
連絡先と場所
研究場所
-
-
Missouri
-
St. Louis、Missouri、アメリカ、63110
- Washington University School of Medicine
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Eligibility Criteria:
- Scheduled to receive radiation therapy.
- At least 18 years of age.
- Does not meet any standard contraindications for MRI (such as being claustrophobic, having metal objects within the body that cannot be removed or having large tattoos), confirmed by completion of our clinical MRI questionnaire form
- Able to understand and willing to sign an IRB approved written informed consent document.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:MRI
Participants will have a custom immobilization device created for them for the purpose of the study.
They will be scanned from one to four occasions during radiation treatment.
If enrolled in the study prior to the first radiation treatment, the first imaging scan may be scheduled prior to the first radiation treatment, with subsequent scans during treatment separated by at least one day.
Patients will be in the scanner for approximately 30 minutes to one hour, either prior to or following their standard of care radiotherapy treatment.
|
他の名前:
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Adequacy of the radiation therapy plan
時間枠:Duration of radiation therapy
|
The radiation plan will be evaluated based on the recorded clinical goals prescribed by the attending physician.
Plans will be classified as 'adequate' if they meet the prescribed goals for the clinical radiation therapy plan.
|
Duration of radiation therapy
|
|
Feasibility of patient localization workflow
時間枠:Duration of radiation therapy
|
The localization time will be classified as 'adequate' if it is less than or equal to 15 minutes.
|
Duration of radiation therapy
|
協力者と研究者
捜査官
- 主任研究者:Jeff Michalski, M.D.、Washington University School of Medicine
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (見積もり)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 201311081
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。