- ICH GCP
- Registro degli studi clinici negli Stati Uniti
- Sperimentazione clinica NCT02331381
Imaging and Plan Workflow in a Novel Low-Field Magnetic Resonance Imaging (MRI) Radiotherapy Device
A Pilot Study of Imaging and Plan Workflow in a Novel Low-Field Magnetic Resonance Imaging (MRI) Radiotherapy Device
Panoramica dello studio
Stato
Condizioni
Intervento / Trattamento
Descrizione dettagliata
Recently, Viewray Inc (Cleveland, OH) has released the RenaissanceTM System 1000, which consists of the combination of an open, split solenoid 0.35 T MRI scanner that is equipped for parallel imaging with a 60Co gamma-ray radiation treatment unit. The MRI scanner is required to be a low field unit to allow for imaging with spatial integrity by limiting magnetic susceptibility artifacts due to the patient and to prevent significant perturbations of the dose distribution. The 0.35 T magnet is a variant of the Siemens MAGNETOM product used for intraoperative imaging.
A previous study of pilot imaging using this device without the 60Co sources was completed in 2012 (HRPO# 201105295). In this study, a total of 26 patients were imaged with the device. Fourteen of these patients also had onboard CT imaging (OB-CT) where the two sets of imaging and relative organs at risk (OARs) could be compared. Fifteen to 24 OARs were evaluated per anatomical site. In total, 221 OARs and 10 target structures were compared for visualization on MRI and OB-CT image sets by each physician. At least 2/3 physicians evaluated MRI as offering better visualization for 71% of structures, OB-CT offering better visualization for 10% of structures, and both offering equivalent visualization for 14% of structures. Physicians agreed unanimously for 74% and in majority for >99% of structures evaluated, respectively. For <1% of structures, no consensus was reached. Targets were better visualized on MRI in 4/10 cases, and were never better visualized on OB-CT images.
There were limitations to this prior study. The patients were not imaged in immobilization devices that are commonly used in radiation therapy. This precluded the creation of a mock radiation therapy plan using the device for these patients. Also, the device was not evaluated in the context of radiation therapy decision making, such as patient shifts, target localization and patient repositioning.
The purpose of this study is to evaluate the imaging and plan workflow for radiation therapy utilizing this novel device. For this protocol, only the MRI scanner of the machine will be utilized. The 60Co portion of the machine capable of radiation treatment administration will not be utilized, and there will be no experimental treatments or modifications to each patient's standard of care radiation treatment plan.
Tipo di studio
Iscrizione (Effettivo)
Fase
- Fase 1
Contatti e Sedi
Luoghi di studio
-
-
Missouri
-
St. Louis, Missouri, Stati Uniti, 63110
- Washington University School of Medicine
-
-
Criteri di partecipazione
Criteri di ammissibilità
Età idonea allo studio
Accetta volontari sani
Sessi ammissibili allo studio
Descrizione
Eligibility Criteria:
- Scheduled to receive radiation therapy.
- At least 18 years of age.
- Does not meet any standard contraindications for MRI (such as being claustrophobic, having metal objects within the body that cannot be removed or having large tattoos), confirmed by completion of our clinical MRI questionnaire form
- Able to understand and willing to sign an IRB approved written informed consent document.
Piano di studio
Come è strutturato lo studio?
Dettagli di progettazione
- Scopo principale: Diagnostico
- Assegnazione: N / A
- Modello interventistico: Assegnazione di gruppo singolo
- Mascheramento: Nessuno (etichetta aperta)
Armi e interventi
Gruppo di partecipanti / Arm |
Intervento / Trattamento |
|---|---|
|
Sperimentale: MRI
Participants will have a custom immobilization device created for them for the purpose of the study.
They will be scanned from one to four occasions during radiation treatment.
If enrolled in the study prior to the first radiation treatment, the first imaging scan may be scheduled prior to the first radiation treatment, with subsequent scans during treatment separated by at least one day.
Patients will be in the scanner for approximately 30 minutes to one hour, either prior to or following their standard of care radiotherapy treatment.
|
Altri nomi:
|
Cosa sta misurando lo studio?
Misure di risultato primarie
Misura del risultato |
Misura Descrizione |
Lasso di tempo |
|---|---|---|
|
Adequacy of the radiation therapy plan
Lasso di tempo: Duration of radiation therapy
|
The radiation plan will be evaluated based on the recorded clinical goals prescribed by the attending physician.
Plans will be classified as 'adequate' if they meet the prescribed goals for the clinical radiation therapy plan.
|
Duration of radiation therapy
|
|
Feasibility of patient localization workflow
Lasso di tempo: Duration of radiation therapy
|
The localization time will be classified as 'adequate' if it is less than or equal to 15 minutes.
|
Duration of radiation therapy
|
Collaboratori e investigatori
Investigatori
- Investigatore principale: Jeff Michalski, M.D., Washington University School of Medicine
Pubblicazioni e link utili
Studiare le date dei record
Studia le date principali
Inizio studio (Effettivo)
Completamento primario (Effettivo)
Completamento dello studio (Effettivo)
Date di iscrizione allo studio
Primo inviato
Primo inviato che soddisfa i criteri di controllo qualità
Primo Inserito (Stima)
Aggiornamenti dei record di studio
Ultimo aggiornamento pubblicato (Effettivo)
Ultimo aggiornamento inviato che soddisfa i criteri QC
Ultimo verificato
Maggiori informazioni
Termini relativi a questo studio
Termini MeSH pertinenti aggiuntivi
Altri numeri di identificazione dello studio
- 201311081
Piano per i dati dei singoli partecipanti (IPD)
Hai intenzione di condividere i dati dei singoli partecipanti (IPD)?
Informazioni su farmaci e dispositivi, documenti di studio
Studia un prodotto farmaceutico regolamentato dalla FDA degli Stati Uniti
Studia un dispositivo regolamentato dalla FDA degli Stati Uniti
prodotto fabbricato ed esportato dagli Stati Uniti
Queste informazioni sono state recuperate direttamente dal sito web clinicaltrials.gov senza alcuna modifica. In caso di richieste di modifica, rimozione o aggiornamento dei dettagli dello studio, contattare register@clinicaltrials.gov. Non appena verrà implementata una modifica su clinicaltrials.gov, questa verrà aggiornata automaticamente anche sul nostro sito web .