このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Autonomic Nervous System Dysfunction in Patients With End-stage Kidney Disease

2022年3月3日 更新者:Faitatzidou Danai、Aristotle University Of Thessaloniki
The prevalence of autonomic nervous system (ANS) dysfunction in patients with end-stage kidney disease (ESKD) is considered to be increased. The uraemic environment, as well as the high incidence of comorbid conditions affecting the ANS function (e.g. diabetes mellitus, autoimmune and degenerative neurological diseases), have been proposed to cause important alterations in ANS function. The vast majority of evidence on the prevalence of ANS dysfunction in ESKD patients is derived from small studies elaborating simple methodology. Noteworthy, with the exception of a study in 27 hemodialysis patients which assessed ANS function before and after dialysis in relation to left ventricular filling pressures, and a 2005 Dutch study in 21 patients whether or not they had hypotension during dialysis, no other study used advanced methods to analyze heart rate or blood pressure variability from beat-to-beat recordings, such as this study. In addition, there is no study so far investigating possible changes in the ANS function per dialysis session. Finally, to the best of our knowledge, this is the first work evaluating possible differences in ANS function in hemodialysis compared with peritoneal dialysis individuals.

調査の概要

状態

募集

詳細な説明

This is an observational study performed in the Department of Nephrology, Hippokration Hospital, Thessaloniki, Greece. For the purposes of this study, adult patients (>18 years) with ESKD being treated with hemodialysis (HD) (on standard thrice-weekly HD treatment) or peritoneal dialysis (PD) for at least 3 months, fulfilling the inclusion/exclusion criteria were invited to participate. PD and HD patients will be matched by a blinded member of our team based on age, gender and dialysis vintage (i.e. the duration of time after the point they started renal replacement therapy for ESRD) in a 1:1 ratio. All included patients signed a written informed consent form. The study protocol was approved by the Ethics Committee of the School of Medicine, Aristotle University of Thessaloniki. All procedures and evaluations are performed according to the Declaration of Helsinki 2013 Amendment.

Evaluation of participants includes the recording of demographics and anthropometric characteristics, medical history, concomitant medications and dialysis-related parameters, as well as physical examination and venous blood sampling for routine laboratory tests. Participants are instructed to visit the Department one hour before the programmed follow-up visit at their unit (PD patients); HD patients are instructed to visit the Department on 2 consecutive days (mid-week dialysis day and the corresponding dialysis-off day). All procedures are performed in a room with an ambient temperature of 23-24oC. Firstly, participants are oriented and familiarized with the experimental procedures and are prepared for the hemodynamic and cardiovascular examinations. Continuous beat-by-beat BP and heart rate are monitored using finger photoplethysmography (Finometer PRO, Finapres Medical Systems, Amsterdam, the Netherlands) throughout the protocol. An inflatable cuff is placed on the middle finger of the non-access hand maintained at heart level. After a 5-min rest, all participants underwent a mental task (countdown from 100 to 0 by 7, performed twice), an orthostatic test (5 min with the patient at the supine position followed by 5 min with the patient in upright position), and a mild physical task [3-minute submaximal handgrip exercise test (set of 30 s exercise at 35% MVC with 3 s rest] (K-Force, K-invent). At the completion of the exercise protocol, the Rate of Perceived Exertion (RPE) is assessed using the Borg scale.

For data analysis, beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands). From pulse pressure profiles, beat-by-beat heart rate (HR) and stroke volume (SV, ml) will be computed, using the Modelflow method; cardiac output (L/min) and systemic vascular resistance (SVR, mmHg.s/mL), will also be computed using Beatscope. HRV analysis will be performed with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019) by the same researcher to eliminate inter-observer variability. R-R interval series will be checked for ectopic beats or artifacts. The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).

研究の種類

観察的

入学 (予想される)

78

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

      • Thessaloniki、ギリシャ、54642
        • 募集
        • Department of Nephrology, Hippokration Hospital
        • コンタクト:

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

全て

サンプリング方法

非確率サンプル

調査対象母集団

ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis

説明

Inclusion Criteria:

  • Age >18 years
  • ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis for at least 3 months
  • Provision of informed written consent

Exclusion Criteria:

  • Antihypertensive treatment modifcation during one month prior to study enrollment
  • Modification of treatment for neurological disorders one month prior to study enrollment
  • Active malignant disease or other comorbidity with poor prognosis
  • History of neurological disorders (e.g. Parkinson's disease, multiple sclerosis, etc) that cause primary ANS dysfunction
  • History of ANS dysfunction secondary to diabetes mellitus, amyloidosis, autoimmune disorders, etc.
  • Active infection or relevant inter-current illness.
  • History of drug or alcohol abuse or severe mental disorder

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
hemodialysis
peritoneal dialysis

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
The difference in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the mental arithmetic test between the examination during the dialysis session and the examination in the out-of-dialysis day
時間枠:Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline

二次結果の測定

結果測定
メジャーの説明
時間枠
The difference in baroreceptor-sensitivity (ms/mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
時間枠:Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke-volume (ml) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
時間枠:Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac-output (L/min) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day
時間枠:Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands).
Baseline
The difference in total-peripheral-resistance during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
時間枠:Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
時間枠:Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between dialysis session start and session end.
時間枠:Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the handgrip test between dialysis session start and session end.
時間枠:Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the handgrip test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the handgrip test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the handgrip test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between dialysis session start and session end
時間枠:Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between dialysis session start and session end.
時間枠:Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke volume (ml) during the orthostatic test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac output (L/min) during the orthostatic test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the orthostatic test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between dialysis session start and session end.
時間枠:Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between hemodialysis and peritoneal dialysis patients:.
時間枠:Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in the baroreceptor sensitivity (ms/mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
時間枠:Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in the stroke volume (ml) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
時間枠:Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the handgrip test between hemodialysis and peritoneal dialysis patients:.
時間枠:Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the cardiac output (L/min) during the handgrip test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
時間枠:Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2021年4月1日

一次修了 (予想される)

2022年3月20日

研究の完了 (予想される)

2022年12月31日

試験登録日

最初に提出

2022年2月23日

QC基準を満たした最初の提出物

2022年3月3日

最初の投稿 (実際)

2022年3月14日

学習記録の更新

投稿された最後の更新 (実際)

2022年3月14日

QC基準を満たした最後の更新が送信されました

2022年3月3日

最終確認日

2022年3月1日

詳しくは

本研究に関する用語

その他の研究ID番号

  • ΔΔ4844

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

未定

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する