Autonomic Nervous System Dysfunction in Patients With End-stage Kidney Disease

2022년 3월 3일 업데이트: Faitatzidou Danai, Aristotle University Of Thessaloniki
The prevalence of autonomic nervous system (ANS) dysfunction in patients with end-stage kidney disease (ESKD) is considered to be increased. The uraemic environment, as well as the high incidence of comorbid conditions affecting the ANS function (e.g. diabetes mellitus, autoimmune and degenerative neurological diseases), have been proposed to cause important alterations in ANS function. The vast majority of evidence on the prevalence of ANS dysfunction in ESKD patients is derived from small studies elaborating simple methodology. Noteworthy, with the exception of a study in 27 hemodialysis patients which assessed ANS function before and after dialysis in relation to left ventricular filling pressures, and a 2005 Dutch study in 21 patients whether or not they had hypotension during dialysis, no other study used advanced methods to analyze heart rate or blood pressure variability from beat-to-beat recordings, such as this study. In addition, there is no study so far investigating possible changes in the ANS function per dialysis session. Finally, to the best of our knowledge, this is the first work evaluating possible differences in ANS function in hemodialysis compared with peritoneal dialysis individuals.

연구 개요

상태

모병

상세 설명

This is an observational study performed in the Department of Nephrology, Hippokration Hospital, Thessaloniki, Greece. For the purposes of this study, adult patients (>18 years) with ESKD being treated with hemodialysis (HD) (on standard thrice-weekly HD treatment) or peritoneal dialysis (PD) for at least 3 months, fulfilling the inclusion/exclusion criteria were invited to participate. PD and HD patients will be matched by a blinded member of our team based on age, gender and dialysis vintage (i.e. the duration of time after the point they started renal replacement therapy for ESRD) in a 1:1 ratio. All included patients signed a written informed consent form. The study protocol was approved by the Ethics Committee of the School of Medicine, Aristotle University of Thessaloniki. All procedures and evaluations are performed according to the Declaration of Helsinki 2013 Amendment.

Evaluation of participants includes the recording of demographics and anthropometric characteristics, medical history, concomitant medications and dialysis-related parameters, as well as physical examination and venous blood sampling for routine laboratory tests. Participants are instructed to visit the Department one hour before the programmed follow-up visit at their unit (PD patients); HD patients are instructed to visit the Department on 2 consecutive days (mid-week dialysis day and the corresponding dialysis-off day). All procedures are performed in a room with an ambient temperature of 23-24oC. Firstly, participants are oriented and familiarized with the experimental procedures and are prepared for the hemodynamic and cardiovascular examinations. Continuous beat-by-beat BP and heart rate are monitored using finger photoplethysmography (Finometer PRO, Finapres Medical Systems, Amsterdam, the Netherlands) throughout the protocol. An inflatable cuff is placed on the middle finger of the non-access hand maintained at heart level. After a 5-min rest, all participants underwent a mental task (countdown from 100 to 0 by 7, performed twice), an orthostatic test (5 min with the patient at the supine position followed by 5 min with the patient in upright position), and a mild physical task [3-minute submaximal handgrip exercise test (set of 30 s exercise at 35% MVC with 3 s rest] (K-Force, K-invent). At the completion of the exercise protocol, the Rate of Perceived Exertion (RPE) is assessed using the Borg scale.

For data analysis, beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands). From pulse pressure profiles, beat-by-beat heart rate (HR) and stroke volume (SV, ml) will be computed, using the Modelflow method; cardiac output (L/min) and systemic vascular resistance (SVR, mmHg.s/mL), will also be computed using Beatscope. HRV analysis will be performed with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019) by the same researcher to eliminate inter-observer variability. R-R interval series will be checked for ectopic beats or artifacts. The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).

연구 유형

관찰

등록 (예상)

78

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

연구 연락처 백업

연구 장소

      • Thessaloniki, 그리스, 54642
        • 모병
        • Department of Nephrology, Hippokration Hospital
        • 연락하다:

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

18년 이상 (성인, 고령자)

건강한 자원 봉사자를 받아들입니다

아니

연구 대상 성별

모두

샘플링 방법

비확률 샘플

연구 인구

ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis

설명

Inclusion Criteria:

  • Age >18 years
  • ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis for at least 3 months
  • Provision of informed written consent

Exclusion Criteria:

  • Antihypertensive treatment modifcation during one month prior to study enrollment
  • Modification of treatment for neurological disorders one month prior to study enrollment
  • Active malignant disease or other comorbidity with poor prognosis
  • History of neurological disorders (e.g. Parkinson's disease, multiple sclerosis, etc) that cause primary ANS dysfunction
  • History of ANS dysfunction secondary to diabetes mellitus, amyloidosis, autoimmune disorders, etc.
  • Active infection or relevant inter-current illness.
  • History of drug or alcohol abuse or severe mental disorder

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

코호트 및 개입

그룹/코호트
hemodialysis
peritoneal dialysis

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
The difference in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the mental arithmetic test between the examination during the dialysis session and the examination in the out-of-dialysis day
기간: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline

2차 결과 측정

결과 측정
측정값 설명
기간
The difference in baroreceptor-sensitivity (ms/mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
기간: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke-volume (ml) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
기간: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac-output (L/min) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day
기간: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands).
Baseline
The difference in total-peripheral-resistance during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
기간: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
기간: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between dialysis session start and session end.
기간: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the handgrip test between dialysis session start and session end.
기간: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the handgrip test between dialysis session start and session end.
기간: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the handgrip test between dialysis session start and session end.
기간: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between dialysis session start and session end.
기간: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the handgrip test between dialysis session start and session end.
기간: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between dialysis session start and session end
기간: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between dialysis session start and session end.
기간: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke volume (ml) during the orthostatic test between dialysis session start and session end.
기간: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac output (L/min) during the orthostatic test between dialysis session start and session end.
기간: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the orthostatic test between dialysis session start and session end.
기간: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between dialysis session start and session end.
기간: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between hemodialysis and peritoneal dialysis patients:.
기간: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in the baroreceptor sensitivity (ms/mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
기간: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in the stroke volume (ml) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
기간: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the handgrip test between hemodialysis and peritoneal dialysis patients:.
기간: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the cardiac output (L/min) during the handgrip test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
기간: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (실제)

2021년 4월 1일

기본 완료 (예상)

2022년 3월 20일

연구 완료 (예상)

2022년 12월 31일

연구 등록 날짜

최초 제출

2022년 2월 23일

QC 기준을 충족하는 최초 제출

2022년 3월 3일

처음 게시됨 (실제)

2022년 3월 14일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2022년 3월 14일

QC 기준을 충족하는 마지막 업데이트 제출

2022년 3월 3일

마지막으로 확인됨

2022년 3월 1일

추가 정보

이 연구와 관련된 용어

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니