Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Autonomic Nervous System Dysfunction in Patients With End-stage Kidney Disease

3 de março de 2022 atualizado por: Faitatzidou Danai, Aristotle University Of Thessaloniki
The prevalence of autonomic nervous system (ANS) dysfunction in patients with end-stage kidney disease (ESKD) is considered to be increased. The uraemic environment, as well as the high incidence of comorbid conditions affecting the ANS function (e.g. diabetes mellitus, autoimmune and degenerative neurological diseases), have been proposed to cause important alterations in ANS function. The vast majority of evidence on the prevalence of ANS dysfunction in ESKD patients is derived from small studies elaborating simple methodology. Noteworthy, with the exception of a study in 27 hemodialysis patients which assessed ANS function before and after dialysis in relation to left ventricular filling pressures, and a 2005 Dutch study in 21 patients whether or not they had hypotension during dialysis, no other study used advanced methods to analyze heart rate or blood pressure variability from beat-to-beat recordings, such as this study. In addition, there is no study so far investigating possible changes in the ANS function per dialysis session. Finally, to the best of our knowledge, this is the first work evaluating possible differences in ANS function in hemodialysis compared with peritoneal dialysis individuals.

Visão geral do estudo

Status

Recrutamento

Descrição detalhada

This is an observational study performed in the Department of Nephrology, Hippokration Hospital, Thessaloniki, Greece. For the purposes of this study, adult patients (>18 years) with ESKD being treated with hemodialysis (HD) (on standard thrice-weekly HD treatment) or peritoneal dialysis (PD) for at least 3 months, fulfilling the inclusion/exclusion criteria were invited to participate. PD and HD patients will be matched by a blinded member of our team based on age, gender and dialysis vintage (i.e. the duration of time after the point they started renal replacement therapy for ESRD) in a 1:1 ratio. All included patients signed a written informed consent form. The study protocol was approved by the Ethics Committee of the School of Medicine, Aristotle University of Thessaloniki. All procedures and evaluations are performed according to the Declaration of Helsinki 2013 Amendment.

Evaluation of participants includes the recording of demographics and anthropometric characteristics, medical history, concomitant medications and dialysis-related parameters, as well as physical examination and venous blood sampling for routine laboratory tests. Participants are instructed to visit the Department one hour before the programmed follow-up visit at their unit (PD patients); HD patients are instructed to visit the Department on 2 consecutive days (mid-week dialysis day and the corresponding dialysis-off day). All procedures are performed in a room with an ambient temperature of 23-24oC. Firstly, participants are oriented and familiarized with the experimental procedures and are prepared for the hemodynamic and cardiovascular examinations. Continuous beat-by-beat BP and heart rate are monitored using finger photoplethysmography (Finometer PRO, Finapres Medical Systems, Amsterdam, the Netherlands) throughout the protocol. An inflatable cuff is placed on the middle finger of the non-access hand maintained at heart level. After a 5-min rest, all participants underwent a mental task (countdown from 100 to 0 by 7, performed twice), an orthostatic test (5 min with the patient at the supine position followed by 5 min with the patient in upright position), and a mild physical task [3-minute submaximal handgrip exercise test (set of 30 s exercise at 35% MVC with 3 s rest] (K-Force, K-invent). At the completion of the exercise protocol, the Rate of Perceived Exertion (RPE) is assessed using the Borg scale.

For data analysis, beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands). From pulse pressure profiles, beat-by-beat heart rate (HR) and stroke volume (SV, ml) will be computed, using the Modelflow method; cardiac output (L/min) and systemic vascular resistance (SVR, mmHg.s/mL), will also be computed using Beatscope. HRV analysis will be performed with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019) by the same researcher to eliminate inter-observer variability. R-R interval series will be checked for ectopic beats or artifacts. The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).

Tipo de estudo

Observacional

Inscrição (Antecipado)

78

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Estude backup de contato

Locais de estudo

      • Thessaloniki, Grécia, 54642
        • Recrutamento
        • Department of Nephrology, Hippokration Hospital
        • Contato:

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Método de amostragem

Amostra Não Probabilística

População do estudo

ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis

Descrição

Inclusion Criteria:

  • Age >18 years
  • ESKD individuals treated with either hemodialysis (standard thrice weekly schedule) or peritoneal dialysis for at least 3 months
  • Provision of informed written consent

Exclusion Criteria:

  • Antihypertensive treatment modifcation during one month prior to study enrollment
  • Modification of treatment for neurological disorders one month prior to study enrollment
  • Active malignant disease or other comorbidity with poor prognosis
  • History of neurological disorders (e.g. Parkinson's disease, multiple sclerosis, etc) that cause primary ANS dysfunction
  • History of ANS dysfunction secondary to diabetes mellitus, amyloidosis, autoimmune disorders, etc.
  • Active infection or relevant inter-current illness.
  • History of drug or alcohol abuse or severe mental disorder

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

Coortes e Intervenções

Grupo / Coorte
hemodialysis
peritoneal dialysis

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
The difference in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the mental arithmetic test between the examination during the dialysis session and the examination in the out-of-dialysis day
Prazo: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
The difference in baroreceptor-sensitivity (ms/mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
Prazo: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke-volume (ml) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
Prazo: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac-output (L/min) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day
Prazo: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands).
Baseline
The difference in total-peripheral-resistance during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
Prazo: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during mental-arithmetic-test between examination during the session and examination in the out-of-dialysis day.
Prazo: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between dialysis session start and session end.
Prazo: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the handgrip test between dialysis session start and session end.
Prazo: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the handgrip test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the handgrip test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the handgrip test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between dialysis session start and session end
Prazo: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between dialysis session start and session end.
Prazo: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in stroke volume (ml) during the orthostatic test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in cardiac output (L/min) during the orthostatic test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the orthostatic test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between dialysis session start and session end.
Prazo: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the handgrip test between hemodialysis and peritoneal dialysis patients:.
Prazo: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in the baroreceptor sensitivity (ms/mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
Prazo: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in the stroke volume (ml) during the handgrip test between hemodialysis and peritoneal dialysis patients:.
Prazo: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the total peripheral resistance during the handgrip test between hemodialysis and peritoneal dialysis patients:.
Prazo: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in the cardiac output (L/min) during the handgrip test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the handgrip test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in in the root mean square of successive R-R differences [RMSSD (ms)] parameter of heart rate variability during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
The root mean square of successive differences (RMSSD) between the coupling intervals of adjacent R-R intervals will be used as a parasympathetic activity index. RMSSD will be calculated with the HRV Analysis software Kubios (version 3.3.1, Kubios Oy, 2019)
Baseline
The difference in baroreceptor sensitivity (ms/mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Baroreceptor sensitivity (ms/mmHg) will be assessed by examining the spontaneous fluctuations in the blood pressure as assessed by the cross-correlation method using the Beatscope 1a software).
Baseline
The difference in cardiac output (L/min) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat cardiac output (L/min) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in total peripheral resistance during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat total peripheral resistance (mmHg.s/mL) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in stroke volume (ml) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat stroke volume (ml) will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline
The difference in both SBP and DBP (mmHg) during the orthostatic test between hemodialysis and peritoneal dialysis patients.
Prazo: Baseline
Beat-by-beat SBP and DBP will be averaged per testing session and exported using the Beatscope software (version 1.a, Finapres Medical Systems, Amsterdam, the Netherlands)
Baseline

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Publicações Gerais

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

1 de abril de 2021

Conclusão Primária (Antecipado)

20 de março de 2022

Conclusão do estudo (Antecipado)

31 de dezembro de 2022

Datas de inscrição no estudo

Enviado pela primeira vez

23 de fevereiro de 2022

Enviado pela primeira vez que atendeu aos critérios de CQ

3 de março de 2022

Primeira postagem (Real)

14 de março de 2022

Atualizações de registro de estudo

Última Atualização Postada (Real)

14 de março de 2022

Última atualização enviada que atendeu aos critérios de controle de qualidade

3 de março de 2022

Última verificação

1 de março de 2022

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

INDECISO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever