このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

AI-Enhanced Single-Lead ECG Screening for Coronary Stenosis

Screening for Significant Coronary Artery Stenosis Using Single-channel Electrocardiogram Analysis With Artificial Intelligence Elements

It is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first - 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second - a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.

All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion.

Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as indicated.

All patients included in the study will undergo ECG recording within 1 month before or after CAG or MSCT in standard lead I for 1 minute, followed by spectral analysis of the obtained data, which will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.

The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.

調査の概要

詳細な説明

The aim of the study:: To develop and evaluate the diagnostic efficacy of a screening method for significant coronary artery stenosis based on data obtained from the analysis of a single-channel electrocardiogram.

This is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first group comprises 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second group is a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.

All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion. Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as clinically indicated. ECG registration in standard lead I will be performed within 3 months before or after the CAG or MSCT.

Obtained data will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.

The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark. It is designed as an iPhone cover. It is registered with the Federal Service for Health Surveillance on February 15, 2019. RZN No. 2019/8124.

The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.

The patient's personal data (last name, first name, patronymic, date of birth, contact information) will not be transferred or taken into account. Each patient is assigned an individual number that is not associated with his/her personal data.

Subsequently, spectral analysis of the electrocardiogram will be performed using machine learning models and/or neural network data analysis.

Then a spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform, the principles of which are based on the Fourier transform.

Analysis of the single-channel ECG involves evaluation of the following parameters (the parameters listed below will be calculated as median beat-to-beat values):

  • TpTe - time from peak to end of the T-wave
  • VAT - time from the beginning of the QRS to the R-peak
  • QTc - corrected QT interval.
  • QT/TQ - the ratio of QT length to TQ length (from the end of T to the beginning of the QRS of the next complex).
  • QRS_E - total energy of the QRS-wave based on wavelet transform
  • T_E - total energy of the T-wave based on wavelet transform
  • TP_E - energy of the main T-wave peak based on wavelet transform
  • BETA, BETA_S - T-wave asymmetry coefficients (simple and smoothed versions)
  • BAD_T - flag of T-wave quality (whether expressed in the current lead)
  • QRS_D1_ons - energy of the leading edge of the R-wave (based on the "first derivative" wavelet transform)
  • QRS_D1_offs - energy of the trailing edge of the R-wave (based on the "first derivative" wavelet transform)
  • QRS_D2 - peak energy of the R-wave (based on the "second derivative" wavelet transform)
  • QRS_Ei (i=1,2,3,4) - QRS-wave energy in 4 frequency ranges (2-4-8-16-32 Hz) based on wavelet transform
  • T_Ei (i=1,2,3,4) - T-wave energy in 4 frequency ranges (2-4-6-8-10 Hz) based on wavelet transform
  • HFQRS - amplitude of the high-frequency components of the QRS-wave

Additionally used parameters:

  • TpTe, VAT, QTc - are duplicated to control the correctness of record processing (the value of the central measure should be approximately equal to the beat-to-beat median).
  • QRSw - QRS width.
  • RA, SA, TA - amplitudes of the R, S, T-waves, respectively, used for normalizing the parameters listed above.

Method of statistical processing of results: SPSS Statistics Version 26 computer program for statistical data processing; construction of machine learning models and/or neural network data analysis The proposed research outcome: development of an algorithm for diagnosing significant coronary stenosis based on single-channel ECG data using elements of artificial intelligence.

The endpoints of the study are the parameters of diagnostic accuracy of the developed model:

  • specificity,
  • sensitivity,
  • prognostic significance of a positive and negative result,
  • diagnostic accuracy.

Тhese metrics will be calculated using receiver operating characteristic (ROC) analysis and confusion matrices on a held-out test set (30% of the dataset) after training multifactorial models (logistic regression, random forest, or neural networks) on single-lead ECG features. Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.

研究の種類

観察的

入学 (推定)

400

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

研究連絡先のバックアップ

研究場所

      • Moscow、ロシア、119435
        • 1 University Hospital

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

サンプリング方法

非確率サンプル

調査対象母集団

All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion. Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as clinically indicated. ECG registration in standard lead I will be performed within 3 months before or after the CAG or MSCT.

説明

Inclusion Criteria:

  • Presence of written informed consent from the patient to participate in the study.
  • Age 18 years and older.
  • Outpatient visit and/or hospitalization at the research center with coronary visualization performed.

Non-inclusion criteria:

  • Absence of sufficient data on coronary anatomy and stenosis significance.
  • Any conditions impairing the quality of single-channel ECG recording (Parkinson's disease, essential tremor, and others).
  • Absence of written informed consent from the patient to participate in the study.

Exclusion Criteria:

  • Patient's unwillingness to continue participation in the study.
  • Inability to perform full analysis of single-channel ECG digital characteristics.
  • Refusal of coronary visualization methods for any reason.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

コホートと介入

グループ/コホート
介入・治療
coronary artery stenosis
200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark. It is designed as an iPhone cover. It is registered with the Federal Service for Health Surveillance on February 15, 2019. RZN No. 2019/8124
control group
200 patients without significant stenosis according to CAG or MSCT data
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark. It is designed as an iPhone cover. It is registered with the Federal Service for Health Surveillance on February 15, 2019. RZN No. 2019/8124

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Sensitivity, specificity, positive/negative predictive values, and overall accuracy
時間枠:From July 2027 to August 2027
Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.
From July 2027 to August 2027

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

一般刊行物

  • Analysis of transitions between linear and nonlinear cardiac rhythm modes in patients with ischemic heart disease / L. V. Mezentseva, P. Sh. Chomakhidze, F. Yu. Kopylov [et al.] // Pathogenesis. - 2017. - Vol. 15, No. 1. - P. 54-58. - DOI 10.25557/GM.2017.1.6952. - EDN ZFALML.
  • Simakov, Sergey, Gamilov, Timur, Danilov, Alexander, Kopylov, Philipp, Chomakhidze, Peter and Liang, Fuyou. "Hemodynamics in residual myocardial ischemia". BIOKYBERNETIKA: Mathematics for Theory and Control in the Human and in Society, edited by Jochen Mau, Sergey Mukhin, Guanyu Wang and Shuhua Xu, Berlin, Boston: De Gruyter, 2025, pp. 319-334. https://doi.org/10.1515/9783111341996-017

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年5月1日

一次修了 (推定)

2027年9月1日

研究の完了 (推定)

2027年12月1日

試験登録日

最初に提出

2026年2月9日

QC基準を満たした最初の提出物

2026年5月6日

最初の投稿 (実際)

2026年5月12日

学習記録の更新

投稿された最後の更新 (実際)

2026年5月12日

QC基準を満たした最後の更新が送信されました

2026年5月6日

最終確認日

2026年4月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

It is not possible to provide documentation due to the prohibition received from the local ethics committee

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する