AI-Enhanced Single-Lead ECG Screening for Coronary Stenosis
Screening for Significant Coronary Artery Stenosis Using Single-channel Electrocardiogram Analysis With Artificial Intelligence Elements
It is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first - 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second - a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.
All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion.
Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as indicated.
All patients included in the study will undergo ECG recording within 1 month before or after CAG or MSCT in standard lead I for 1 minute, followed by spectral analysis of the obtained data, which will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.
The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.
研究概览
详细说明
The aim of the study:: To develop and evaluate the diagnostic efficacy of a screening method for significant coronary artery stenosis based on data obtained from the analysis of a single-channel electrocardiogram.
This is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first group comprises 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second group is a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.
All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion. Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as clinically indicated. ECG registration in standard lead I will be performed within 3 months before or after the CAG or MSCT.
Obtained data will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark. It is designed as an iPhone cover. It is registered with the Federal Service for Health Surveillance on February 15, 2019. RZN No. 2019/8124.
The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.
The patient's personal data (last name, first name, patronymic, date of birth, contact information) will not be transferred or taken into account. Each patient is assigned an individual number that is not associated with his/her personal data.
Subsequently, spectral analysis of the electrocardiogram will be performed using machine learning models and/or neural network data analysis.
Then a spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform, the principles of which are based on the Fourier transform.
Analysis of the single-channel ECG involves evaluation of the following parameters (the parameters listed below will be calculated as median beat-to-beat values):
- TpTe - time from peak to end of the T-wave
- VAT - time from the beginning of the QRS to the R-peak
- QTc - corrected QT interval.
- QT/TQ - the ratio of QT length to TQ length (from the end of T to the beginning of the QRS of the next complex).
- QRS_E - total energy of the QRS-wave based on wavelet transform
- T_E - total energy of the T-wave based on wavelet transform
- TP_E - energy of the main T-wave peak based on wavelet transform
- BETA, BETA_S - T-wave asymmetry coefficients (simple and smoothed versions)
- BAD_T - flag of T-wave quality (whether expressed in the current lead)
- QRS_D1_ons - energy of the leading edge of the R-wave (based on the "first derivative" wavelet transform)
- QRS_D1_offs - energy of the trailing edge of the R-wave (based on the "first derivative" wavelet transform)
- QRS_D2 - peak energy of the R-wave (based on the "second derivative" wavelet transform)
- QRS_Ei (i=1,2,3,4) - QRS-wave energy in 4 frequency ranges (2-4-8-16-32 Hz) based on wavelet transform
- T_Ei (i=1,2,3,4) - T-wave energy in 4 frequency ranges (2-4-6-8-10 Hz) based on wavelet transform
- HFQRS - amplitude of the high-frequency components of the QRS-wave
Additionally used parameters:
- TpTe, VAT, QTc - are duplicated to control the correctness of record processing (the value of the central measure should be approximately equal to the beat-to-beat median).
- QRSw - QRS width.
- RA, SA, TA - amplitudes of the R, S, T-waves, respectively, used for normalizing the parameters listed above.
Method of statistical processing of results: SPSS Statistics Version 26 computer program for statistical data processing; construction of machine learning models and/or neural network data analysis The proposed research outcome: development of an algorithm for diagnosing significant coronary stenosis based on single-channel ECG data using elements of artificial intelligence.
The endpoints of the study are the parameters of diagnostic accuracy of the developed model:
- specificity,
- sensitivity,
- prognostic significance of a positive and negative result,
- diagnostic accuracy.
Тhese metrics will be calculated using receiver operating characteristic (ROC) analysis and confusion matrices on a held-out test set (30% of the dataset) after training multifactorial models (logistic regression, random forest, or neural networks) on single-lead ECG features. Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.
研究类型
注册 (估计的)
联系人和位置
学习联系方式
- 姓名:Petr Chomakhidze, Professor
- 电话号码:+79166740369
- 邮箱:chomakhidze_p_sh@staff.sechenov.ru
研究联系人备份
- 姓名:Liana Khromova, Dr.
- 电话号码:+79083018204
- 邮箱:liana.khromova@mail.ru
学习地点
-
-
-
Moscow、俄罗斯、119435
- 1 University Hospital
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
取样方法
研究人群
描述
Inclusion Criteria:
- Presence of written informed consent from the patient to participate in the study.
- Age 18 years and older.
- Outpatient visit and/or hospitalization at the research center with coronary visualization performed.
Non-inclusion criteria:
- Absence of sufficient data on coronary anatomy and stenosis significance.
- Any conditions impairing the quality of single-channel ECG recording (Parkinson's disease, essential tremor, and others).
- Absence of written informed consent from the patient to participate in the study.
Exclusion Criteria:
- Patient's unwillingness to continue participation in the study.
- Inability to perform full analysis of single-channel ECG digital characteristics.
- Refusal of coronary visualization methods for any reason.
学习计划
研究是如何设计的?
设计细节
队列和干预
团体/队列 |
干预/治疗 |
|---|---|
|
coronary artery stenosis
200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results
|
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark.
It is designed as an iPhone cover.
It is registered with the Federal Service for Health Surveillance on February 15, 2019.
RZN No. 2019/8124
|
|
control group
200 patients without significant stenosis according to CAG or MSCT data
|
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark.
It is designed as an iPhone cover.
It is registered with the Federal Service for Health Surveillance on February 15, 2019.
RZN No. 2019/8124
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Sensitivity, specificity, positive/negative predictive values, and overall accuracy
大体时间:From July 2027 to August 2027
|
Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.
|
From July 2027 to August 2027
|
合作者和调查者
出版物和有用的链接
一般刊物
- Analysis of transitions between linear and nonlinear cardiac rhythm modes in patients with ischemic heart disease / L. V. Mezentseva, P. Sh. Chomakhidze, F. Yu. Kopylov [et al.] // Pathogenesis. - 2017. - Vol. 15, No. 1. - P. 54-58. - DOI 10.25557/GM.2017.1.6952. - EDN ZFALML.
- Simakov, Sergey, Gamilov, Timur, Danilov, Alexander, Kopylov, Philipp, Chomakhidze, Peter and Liang, Fuyou. "Hemodynamics in residual myocardial ischemia". BIOKYBERNETIKA: Mathematics for Theory and Control in the Human and in Society, edited by Jochen Mau, Sergey Mukhin, Guanyu Wang and Shuhua Xu, Berlin, Boston: De Gruyter, 2025, pp. 319-334. https://doi.org/10.1515/9783111341996-017
研究记录日期
研究主要日期
学习开始 (估计的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- ChPSH22261
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.