AI-Enhanced Single-Lead ECG Screening for Coronary Stenosis
Screening for Significant Coronary Artery Stenosis Using Single-channel Electrocardiogram Analysis With Artificial Intelligence Elements
It is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first - 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second - a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.
All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion.
Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as indicated.
All patients included in the study will undergo ECG recording within 1 month before or after CAG or MSCT in standard lead I for 1 minute, followed by spectral analysis of the obtained data, which will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.
The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.
Aperçu de l'étude
Statut
Les conditions
Intervention / Traitement
Description détaillée
The aim of the study:: To develop and evaluate the diagnostic efficacy of a screening method for significant coronary artery stenosis based on data obtained from the analysis of a single-channel electrocardiogram.
This is a prospective, controlled, single-center, non-randomized, observational study. Two patient groups are planned for inclusion: the first group comprises 200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results; the second group is a control group consisting of 200 patients without significant stenosis according to CAG or MSCT data.
All study subjects will have a date of coronary artery imaging via CAG or MSCT with assessment of myocardial perfusion. Stress echocardiography tests or fractional flow reserve (FFR) assessment will be conducted as clinically indicated. ECG registration in standard lead I will be performed within 3 months before or after the CAG or MSCT.
Obtained data will be stored at the remote monitoring center of Sechenov University without being linked to the personal data of patients. A spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform.
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark. It is designed as an iPhone cover. It is registered with the Federal Service for Health Surveillance on February 15, 2019. RZN No. 2019/8124.
The result of this study will be the identification of ECG parameters that correlate with significant coronary artery stenosis.
The patient's personal data (last name, first name, patronymic, date of birth, contact information) will not be transferred or taken into account. Each patient is assigned an individual number that is not associated with his/her personal data.
Subsequently, spectral analysis of the electrocardiogram will be performed using machine learning models and/or neural network data analysis.
Then a spectral analysis of the electrocardiogram will be performed using a continuous wavelet transform, the principles of which are based on the Fourier transform.
Analysis of the single-channel ECG involves evaluation of the following parameters (the parameters listed below will be calculated as median beat-to-beat values):
- TpTe - time from peak to end of the T-wave
- VAT - time from the beginning of the QRS to the R-peak
- QTc - corrected QT interval.
- QT/TQ - the ratio of QT length to TQ length (from the end of T to the beginning of the QRS of the next complex).
- QRS_E - total energy of the QRS-wave based on wavelet transform
- T_E - total energy of the T-wave based on wavelet transform
- TP_E - energy of the main T-wave peak based on wavelet transform
- BETA, BETA_S - T-wave asymmetry coefficients (simple and smoothed versions)
- BAD_T - flag of T-wave quality (whether expressed in the current lead)
- QRS_D1_ons - energy of the leading edge of the R-wave (based on the "first derivative" wavelet transform)
- QRS_D1_offs - energy of the trailing edge of the R-wave (based on the "first derivative" wavelet transform)
- QRS_D2 - peak energy of the R-wave (based on the "second derivative" wavelet transform)
- QRS_Ei (i=1,2,3,4) - QRS-wave energy in 4 frequency ranges (2-4-8-16-32 Hz) based on wavelet transform
- T_Ei (i=1,2,3,4) - T-wave energy in 4 frequency ranges (2-4-6-8-10 Hz) based on wavelet transform
- HFQRS - amplitude of the high-frequency components of the QRS-wave
Additionally used parameters:
- TpTe, VAT, QTc - are duplicated to control the correctness of record processing (the value of the central measure should be approximately equal to the beat-to-beat median).
- QRSw - QRS width.
- RA, SA, TA - amplitudes of the R, S, T-waves, respectively, used for normalizing the parameters listed above.
Method of statistical processing of results: SPSS Statistics Version 26 computer program for statistical data processing; construction of machine learning models and/or neural network data analysis The proposed research outcome: development of an algorithm for diagnosing significant coronary stenosis based on single-channel ECG data using elements of artificial intelligence.
The endpoints of the study are the parameters of diagnostic accuracy of the developed model:
- specificity,
- sensitivity,
- prognostic significance of a positive and negative result,
- diagnostic accuracy.
Тhese metrics will be calculated using receiver operating characteristic (ROC) analysis and confusion matrices on a held-out test set (30% of the dataset) after training multifactorial models (logistic regression, random forest, or neural networks) on single-lead ECG features. Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.
Type d'étude
Inscription (Estimé)
Contacts et emplacements
Coordonnées de l'étude
- Nom: Petr Chomakhidze, Professor
- Numéro de téléphone: +79166740369
- E-mail: chomakhidze_p_sh@staff.sechenov.ru
Sauvegarde des contacts de l'étude
- Nom: Liana Khromova, Dr.
- Numéro de téléphone: +79083018204
- E-mail: liana.khromova@mail.ru
Lieux d'étude
-
-
-
Moscow, Russie, 119435
- 1 University Hospital
-
-
Critères de participation
Critère d'éligibilité
Âges éligibles pour étudier
- Adulte
- Adulte plus âgé
Accepte les volontaires sains
Méthode d'échantillonnage
Population étudiée
La description
Inclusion Criteria:
- Presence of written informed consent from the patient to participate in the study.
- Age 18 years and older.
- Outpatient visit and/or hospitalization at the research center with coronary visualization performed.
Non-inclusion criteria:
- Absence of sufficient data on coronary anatomy and stenosis significance.
- Any conditions impairing the quality of single-channel ECG recording (Parkinson's disease, essential tremor, and others).
- Absence of written informed consent from the patient to participate in the study.
Exclusion Criteria:
- Patient's unwillingness to continue participation in the study.
- Inability to perform full analysis of single-channel ECG digital characteristics.
- Refusal of coronary visualization methods for any reason.
Plan d'étude
Comment l'étude est-elle conçue ?
Détails de conception
Cohortes et interventions
Groupe / Cohorte |
Intervention / Traitement |
|---|---|
|
coronary artery stenosis
200 patients with significant coronary artery stenosis confirmed by coronary angiography (CAG) or multislice computed tomography (MSCT) results
|
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark.
It is designed as an iPhone cover.
It is registered with the Federal Service for Health Surveillance on February 15, 2019.
RZN No. 2019/8124
|
|
control group
200 patients without significant stenosis according to CAG or MSCT data
|
The single-channel ECG will be recorded using the portable single-lead ECG monitor CardioQvark.
It is designed as an iPhone cover.
It is registered with the Federal Service for Health Surveillance on February 15, 2019.
RZN No. 2019/8124
|
Que mesure l'étude ?
Principaux critères de jugement
Mesure des résultats |
Description de la mesure |
Délai |
|---|---|---|
|
Sensitivity, specificity, positive/negative predictive values, and overall accuracy
Délai: From July 2027 to August 2027
|
Sensitivity, specificity, positive/negative predictive values, and overall accuracy will be derived by comparing model predictions of significant coronary stenosis (≥50% lumen narrowing per CAG/MSCT) against the gold standard, with cross-validation (k=5 folds) to ensure robustness and bootstrap resampling for 95% confidence intervals.
|
From July 2027 to August 2027
|
Collaborateurs et enquêteurs
Publications et liens utiles
Publications générales
- Analysis of transitions between linear and nonlinear cardiac rhythm modes in patients with ischemic heart disease / L. V. Mezentseva, P. Sh. Chomakhidze, F. Yu. Kopylov [et al.] // Pathogenesis. - 2017. - Vol. 15, No. 1. - P. 54-58. - DOI 10.25557/GM.2017.1.6952. - EDN ZFALML.
- Simakov, Sergey, Gamilov, Timur, Danilov, Alexander, Kopylov, Philipp, Chomakhidze, Peter and Liang, Fuyou. "Hemodynamics in residual myocardial ischemia". BIOKYBERNETIKA: Mathematics for Theory and Control in the Human and in Society, edited by Jochen Mau, Sergey Mukhin, Guanyu Wang and Shuhua Xu, Berlin, Boston: De Gruyter, 2025, pp. 319-334. https://doi.org/10.1515/9783111341996-017
Dates d'enregistrement des études
Dates principales de l'étude
Début de l'étude (Estimé)
Achèvement primaire (Estimé)
Achèvement de l'étude (Estimé)
Dates d'inscription aux études
Première soumission
Première soumission répondant aux critères de contrôle qualité
Première publication (Réel)
Mises à jour des dossiers d'étude
Dernière mise à jour publiée (Réel)
Dernière mise à jour soumise répondant aux critères de contrôle qualité
Dernière vérification
Plus d'information
Termes liés à cette étude
Mots clés
Termes MeSH pertinents supplémentaires
- La douleur
- Manifestations neurologiques
- Maladies vasculaires
- Maladies cardiovasculaires
- Maladies cardiaques
- Maladie coronarienne
- Douleur thoracique
- Conditions pathologiques, signes et symptômes
- Signes et symptômes
- Sténose coronaire
- Ischémie myocardique
- Syndrome coronarien aigu
- Angine de poitrine
- Angine stable
Autres numéros d'identification d'étude
- ChPSH22261
Plan pour les données individuelles des participants (IPD)
Prévoyez-vous de partager les données individuelles des participants (DPI) ?
Description du régime IPD
Informations sur les médicaments et les dispositifs, documents d'étude
Étudie un produit pharmaceutique réglementé par la FDA américaine
Étudie un produit d'appareil réglementé par la FDA américaine
Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .