このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Eccentric Muscle Training in Cardiac Rehabilitation

2026年6月3日 更新者:University Hospital, Antwerp

Eccentric Muscle Training in Cardiac Rehabilitation: Randomized Controlled Trial to Evaluate Effectiveness and Feasibility in Heart Failure Patients With Reduced Ejection Fraction

The goal of this interventional study is to assess the training effects in a training schedule in which eccentric overload training and eccentric cycle training are used.

Researchers will compare a training program of eccentric overload training and eccentric cycling training with a traditional training program of strength and cardio training in people with heart failure with reduced ejection fraction.

This study will be delivered in a cardiac rehabilitation setting.

調査の概要

詳細な説明

Patients with HFrEF experience in general more difficulties completing exercise training trajectory because of low physical fitness and multiple comorbidies.

In this study traditional exercise capacity outcomes are assessed eg. endurance capacity, muscle strength and muscle mass in patients with HFrEF.

It is hypothesized that greater muscle strength and muscle mass are obtained by eccentric muscle training in comparison with conventional training because higher training volumes can be used with a lower metabolic demand.

Possibly, a better outcome regarding muscle function and mass will influence VO2 peak and functionality in this patient population.

研究の種類

介入

入学 (推定)

3

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

  • 名前:Wendy Hens, PhD
  • 電話番号:0032 3 275 73 89
  • メール:wendy.hens@uza.be

研究場所

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 子
  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • HFrEF patients with ejection fraction <40%
  • Exercise intolerance (<85% of predicted VO2 peak)
  • clinically stable for > 6 weeks, optimal medical treatment for > 6 weeks

Exclusion Criteria:

  • Contra indications for cardiac exercise rehabilitation as per consensus guidelines and recommendations
  • Musculoskeletal disorders that hamper (progression in) strength training
  • Non-stabilized acute coronary syndrome
  • Current acute heart failure (decompensation)
  • Patient having sustained a recent (<3 months) procedure that could act as a confounder to increase VO2peak (i.e., coronary artery bypass graft surgery, percutaneous coronary intervention, cardiac resynchronization therapy, valve surgery or reparation)

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:トリプル

武器と介入

参加者グループ / アーム
介入・治療
実験的:Eccentric strength training + cardio
45 sessions experimental protocol
progressive following protocol, 10min
dynamic strength training + eccentric overload, progressive over time, 3sets*10reps (15-20min)
aerobic training, progressive over time, 10 min
アクティブコンパレータ:Traditional strength training + cardio
45 sessions traditional cardiac rehabilitation
aerobic training, progressive over time, 10 min
aerobic training, progressive following protocol, 10 min
dynamic strength training, progression over time, 15-20 min

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
1Repetition Maximum (=RM) leg press (kg)
時間枠:pre (baseline) + post (15 weeks)

One repetition maximum on leg press device Technogym BioCircuit. The patient is positioned correctly on the leg press (back supported, feet on platform in standardized way so that repeated tests are in the same position).

The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm.

The system identifies the maximum successful single push as the 1RM (kg).

pre (baseline) + post (15 weeks)
1Repetition Maximum (=RM) Low Row (kg)
時間枠:pre (baseline) + post (15weeks)

One repetition maximum on the low row device Technogym BioCircuit. The patient sits with chest supported, feet on the ground, and grips the handles with arms extended.

The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single lift as the 1RM (kg).

pre (baseline) + post (15weeks)
1Repetition Maximum (=RM) chest press (kg)
時間枠:pre (baseline) + post (15weeks)
One repetition maximum on chest press device Technogym BioCircuit. The patient is positioned correctly on the chest press (back supported, feet on the ground in standardized way so that repeated tests are in the same position). The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single push as the 1RM (kg).
pre (baseline) + post (15weeks)
1Repetition Maximum (=RM) vertical traction (kg)
時間枠:pre (baseline) + post (15weeks)

One repetition maximum on vertical traction device Technogym BioCircuit. The patient is positioned correctly on the vertical traction (back supported, feet on the ground in standardized way so that repeated tests are in the same position).

The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm.

The system identifies the maximum successful single push as the 1RM (kg).

pre (baseline) + post (15weeks)
Handgrip strength
時間枠:pre (baseline) + post (15 weeks)

The Jamar handgrip dynamometer is used to measure grip strength in a standardized way ( 90° flex elbow, forearm neutral, and wrist slightly extended).

3 trials per hand are performed, with 10seconds rest in between. The average value is recorded as grip strength.

pre (baseline) + post (15 weeks)
Isometric Qceps peak torque (Nm)
時間枠:pre (baseline) + post (15weeks)

The subject is seated in the Biodex System dynamometer and securely strapped (trunk, pelvis, thigh). The dynamometer axis is aligned with the knee joint axis (lateral femoral epicondyle).

The knee is fixed at 60° of flexion (0° = full extension). The lower leg is attached to the lever arm just above the ankle. The subject performs a maximal isometric knee extension (pushing against the immovable arm) for 3seconds.

3 tests are done with 10seconds rest in between. The highest torque value (Nm) recorded is taken as the quadriceps peak torque.

pre (baseline) + post (15weeks)

二次結果の測定

結果測定
メジャーの説明
時間枠
6mwt (m)
時間枠:pre (baseline) - post (15weeks)

The 6-minute walk test (6MWT) assesses functional exercise capacity by measuring the distance walked in 6 minutes.

It is performed on the same flat, straight corridor (50 meter) with marked turnaround points.

The participant is instructed to walk as fast as possible at a self-paced speed.

Standardized encouragement is given every minute. A timer is started at the beginning and stopped at 6 minutes. The total distance walked is measured in meters.

pre (baseline) - post (15weeks)
Time up and go (s)
時間枠:pre (baseline) + post (15weeks)

The participant starts seated in a standard chair (back against the chair, no armrests) On the command "go," the participant stands up, walks 3 meters, turns around, walks back, and sits down again.

Timing starts on "go" and stops when the participant is seated again with the back against the chair). The test is performed 3 times (with 20seconds rest in between).

The outcome is the mean time taken to complete the 3 tasks (seconds).

pre (baseline) + post (15weeks)
VO2 peak (ml/kg/min)
時間枠:pre (baseline) + post (15weeks)

VO₂peak is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test.

The participant cycles at a constant cadence(≈60-70 revolutions/min) until volitional exhaustion. Expired gases are analyzed to determine oxygen uptake (VO₂) and carbon dioxide production (VCO₂). Strong verbal encouragement is given to reach maximal effort. VO₂peak is defined as the mean VO₂ value averaged over the final 30 seconds of exercise.

Test termination follows symptom limitation or standard clinical safety criteria.

pre (baseline) + post (15weeks)
maximal load (Watt)
時間枠:pre (baseline) + post (15weeks)

Wattmax is determined during a CPET performed on a Lode Corival ergometer with monitoring via a Vyaire Medical system.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

Wattmax is defined as the highest workload (in watts) achieved in the final stage.

Strong encouragement is provided to achieve maximal effort.

pre (baseline) + post (15weeks)
VO2/W slope (ml/min/W)
時間枠:pre (baseline) + post (15weeks)

VO2/W slope is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

The relationship between VO₂ (y-axis) and work rate (x-axis) is plotted. A linear regression is applied. The slope of this line represents the VO₂/W slope (mL/min/W).

pre (baseline) + post (15weeks)
VE/VCO2 slope
時間枠:pre (baseline) + post (15weeks)

The VE/VCO₂ slope is measured during CPET on a Lode Corival ergometer with breath-by-breath analysis via Vyaire Medical.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

VE is plotted against VCO₂ over the course of exercise. A linear regression is applied from the start of exercise up to the ventilatory compensation point.

The slope of this relationship represents the VE/VCO₂ slope.

pre (baseline) + post (15weeks)

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2023年1月20日

一次修了 (推定)

2026年9月30日

研究の完了 (推定)

2027年1月1日

試験登録日

最初に提出

2025年12月1日

QC基準を満たした最初の提出物

2026年6月3日

最初の投稿 (実際)

2026年6月9日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月9日

QC基準を満たした最後の更新が送信されました

2026年6月3日

最終確認日

2026年4月1日

詳しくは

本研究に関する用語

キーワード

その他の研究ID番号

  • EDGE 002632
  • Belgian Heart Fund (その他の助成金/資金番号:King Baudouin Foundation)

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

depending on collaboration - if in line with privacy policy this might be done

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する