Eccentric Muscle Training in Cardiac Rehabilitation

3. juni 2026 oppdatert av: University Hospital, Antwerp

Eccentric Muscle Training in Cardiac Rehabilitation: Randomized Controlled Trial to Evaluate Effectiveness and Feasibility in Heart Failure Patients With Reduced Ejection Fraction

The goal of this interventional study is to assess the training effects in a training schedule in which eccentric overload training and eccentric cycle training are used.

Researchers will compare a training program of eccentric overload training and eccentric cycling training with a traditional training program of strength and cardio training in people with heart failure with reduced ejection fraction.

This study will be delivered in a cardiac rehabilitation setting.

Studieoversikt

Detaljert beskrivelse

Patients with HFrEF experience in general more difficulties completing exercise training trajectory because of low physical fitness and multiple comorbidies.

In this study traditional exercise capacity outcomes are assessed eg. endurance capacity, muscle strength and muscle mass in patients with HFrEF.

It is hypothesized that greater muscle strength and muscle mass are obtained by eccentric muscle training in comparison with conventional training because higher training volumes can be used with a lower metabolic demand.

Possibly, a better outcome regarding muscle function and mass will influence VO2 peak and functionality in this patient population.

Studietype

Intervensjonell

Registrering (Antatt)

3

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Studiesteder

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

  • Barn
  • Voksen
  • Eldre voksen

Tar imot friske frivillige

Nei

Beskrivelse

Inclusion Criteria:

  • HFrEF patients with ejection fraction <40%
  • Exercise intolerance (<85% of predicted VO2 peak)
  • clinically stable for > 6 weeks, optimal medical treatment for > 6 weeks

Exclusion Criteria:

  • Contra indications for cardiac exercise rehabilitation as per consensus guidelines and recommendations
  • Musculoskeletal disorders that hamper (progression in) strength training
  • Non-stabilized acute coronary syndrome
  • Current acute heart failure (decompensation)
  • Patient having sustained a recent (<3 months) procedure that could act as a confounder to increase VO2peak (i.e., coronary artery bypass graft surgery, percutaneous coronary intervention, cardiac resynchronization therapy, valve surgery or reparation)

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Behandling
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Trippel

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: Eccentric strength training + cardio
45 sessions experimental protocol
progressive following protocol, 10min
dynamic strength training + eccentric overload, progressive over time, 3sets*10reps (15-20min)
aerobic training, progressive over time, 10 min
Aktiv komparator: Traditional strength training + cardio
45 sessions traditional cardiac rehabilitation
aerobic training, progressive over time, 10 min
aerobic training, progressive following protocol, 10 min
dynamic strength training, progression over time, 15-20 min

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
1Repetition Maximum (=RM) leg press (kg)
Tidsramme: pre (baseline) + post (15 weeks)

One repetition maximum on leg press device Technogym BioCircuit. The patient is positioned correctly on the leg press (back supported, feet on platform in standardized way so that repeated tests are in the same position).

The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm.

The system identifies the maximum successful single push as the 1RM (kg).

pre (baseline) + post (15 weeks)
1Repetition Maximum (=RM) Low Row (kg)
Tidsramme: pre (baseline) + post (15weeks)

One repetition maximum on the low row device Technogym BioCircuit. The patient sits with chest supported, feet on the ground, and grips the handles with arms extended.

The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single lift as the 1RM (kg).

pre (baseline) + post (15weeks)
1Repetition Maximum (=RM) chest press (kg)
Tidsramme: pre (baseline) + post (15weeks)
One repetition maximum on chest press device Technogym BioCircuit. The patient is positioned correctly on the chest press (back supported, feet on the ground in standardized way so that repeated tests are in the same position). The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single push as the 1RM (kg).
pre (baseline) + post (15weeks)
1Repetition Maximum (=RM) vertical traction (kg)
Tidsramme: pre (baseline) + post (15weeks)

One repetition maximum on vertical traction device Technogym BioCircuit. The patient is positioned correctly on the vertical traction (back supported, feet on the ground in standardized way so that repeated tests are in the same position).

The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm.

The system identifies the maximum successful single push as the 1RM (kg).

pre (baseline) + post (15weeks)
Handgrip strength
Tidsramme: pre (baseline) + post (15 weeks)

The Jamar handgrip dynamometer is used to measure grip strength in a standardized way ( 90° flex elbow, forearm neutral, and wrist slightly extended).

3 trials per hand are performed, with 10seconds rest in between. The average value is recorded as grip strength.

pre (baseline) + post (15 weeks)
Isometric Qceps peak torque (Nm)
Tidsramme: pre (baseline) + post (15weeks)

The subject is seated in the Biodex System dynamometer and securely strapped (trunk, pelvis, thigh). The dynamometer axis is aligned with the knee joint axis (lateral femoral epicondyle).

The knee is fixed at 60° of flexion (0° = full extension). The lower leg is attached to the lever arm just above the ankle. The subject performs a maximal isometric knee extension (pushing against the immovable arm) for 3seconds.

3 tests are done with 10seconds rest in between. The highest torque value (Nm) recorded is taken as the quadriceps peak torque.

pre (baseline) + post (15weeks)

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
6mwt (m)
Tidsramme: pre (baseline) - post (15weeks)

The 6-minute walk test (6MWT) assesses functional exercise capacity by measuring the distance walked in 6 minutes.

It is performed on the same flat, straight corridor (50 meter) with marked turnaround points.

The participant is instructed to walk as fast as possible at a self-paced speed.

Standardized encouragement is given every minute. A timer is started at the beginning and stopped at 6 minutes. The total distance walked is measured in meters.

pre (baseline) - post (15weeks)
Time up and go (s)
Tidsramme: pre (baseline) + post (15weeks)

The participant starts seated in a standard chair (back against the chair, no armrests) On the command "go," the participant stands up, walks 3 meters, turns around, walks back, and sits down again.

Timing starts on "go" and stops when the participant is seated again with the back against the chair). The test is performed 3 times (with 20seconds rest in between).

The outcome is the mean time taken to complete the 3 tasks (seconds).

pre (baseline) + post (15weeks)
VO2 peak (ml/kg/min)
Tidsramme: pre (baseline) + post (15weeks)

VO₂peak is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test.

The participant cycles at a constant cadence(≈60-70 revolutions/min) until volitional exhaustion. Expired gases are analyzed to determine oxygen uptake (VO₂) and carbon dioxide production (VCO₂). Strong verbal encouragement is given to reach maximal effort. VO₂peak is defined as the mean VO₂ value averaged over the final 30 seconds of exercise.

Test termination follows symptom limitation or standard clinical safety criteria.

pre (baseline) + post (15weeks)
maximal load (Watt)
Tidsramme: pre (baseline) + post (15weeks)

Wattmax is determined during a CPET performed on a Lode Corival ergometer with monitoring via a Vyaire Medical system.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

Wattmax is defined as the highest workload (in watts) achieved in the final stage.

Strong encouragement is provided to achieve maximal effort.

pre (baseline) + post (15weeks)
VO2/W slope (ml/min/W)
Tidsramme: pre (baseline) + post (15weeks)

VO2/W slope is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

The relationship between VO₂ (y-axis) and work rate (x-axis) is plotted. A linear regression is applied. The slope of this line represents the VO₂/W slope (mL/min/W).

pre (baseline) + post (15weeks)
VE/VCO2 slope
Tidsramme: pre (baseline) + post (15weeks)

The VE/VCO₂ slope is measured during CPET on a Lode Corival ergometer with breath-by-breath analysis via Vyaire Medical.

After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion.

VE is plotted against VCO₂ over the course of exercise. A linear regression is applied from the start of exercise up to the ventilatory compensation point.

The slope of this relationship represents the VE/VCO₂ slope.

pre (baseline) + post (15weeks)

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Faktiske)

20. januar 2023

Primær fullføring (Antatt)

30. september 2026

Studiet fullført (Antatt)

1. januar 2027

Datoer for studieregistrering

Først innsendt

1. desember 2025

Først innsendt som oppfylte QC-kriteriene

3. juni 2026

Først lagt ut (Faktiske)

9. juni 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

9. juni 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

3. juni 2026

Sist bekreftet

1. april 2026

Mer informasjon

Begreper knyttet til denne studien

Andre studie-ID-numre

  • EDGE 002632
  • Belgian Heart Fund (Annet stipend/finansieringsnummer: King Baudouin Foundation)

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

IPD-planbeskrivelse

depending on collaboration - if in line with privacy policy this might be done

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .