Eccentric Muscle Training in Cardiac Rehabilitation
Eccentric Muscle Training in Cardiac Rehabilitation: Randomized Controlled Trial to Evaluate Effectiveness and Feasibility in Heart Failure Patients With Reduced Ejection Fraction
The goal of this interventional study is to assess the training effects in a training schedule in which eccentric overload training and eccentric cycle training are used.
Researchers will compare a training program of eccentric overload training and eccentric cycling training with a traditional training program of strength and cardio training in people with heart failure with reduced ejection fraction.
This study will be delivered in a cardiac rehabilitation setting.
研究概览
地位
详细说明
Patients with HFrEF experience in general more difficulties completing exercise training trajectory because of low physical fitness and multiple comorbidies.
In this study traditional exercise capacity outcomes are assessed eg. endurance capacity, muscle strength and muscle mass in patients with HFrEF.
It is hypothesized that greater muscle strength and muscle mass are obtained by eccentric muscle training in comparison with conventional training because higher training volumes can be used with a lower metabolic demand.
Possibly, a better outcome regarding muscle function and mass will influence VO2 peak and functionality in this patient population.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习联系方式
- 姓名:Wendy Hens, PhD
- 电话号码:0032 3 275 73 89
- 邮箱:wendy.hens@uza.be
学习地点
-
-
-
Edegem、比利时、2850
- 招聘中
- UHAntwerp
-
接触:
- Wendy Hens, PhD
- 电话号码:0032 3 275 73 89
- 邮箱:wendy.hens@uza.be
-
接触:
-
-
参与标准
资格标准
适合学习的年龄
- 孩子
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- HFrEF patients with ejection fraction <40%
- Exercise intolerance (<85% of predicted VO2 peak)
- clinically stable for > 6 weeks, optimal medical treatment for > 6 weeks
Exclusion Criteria:
- Contra indications for cardiac exercise rehabilitation as per consensus guidelines and recommendations
- Musculoskeletal disorders that hamper (progression in) strength training
- Non-stabilized acute coronary syndrome
- Current acute heart failure (decompensation)
- Patient having sustained a recent (<3 months) procedure that could act as a confounder to increase VO2peak (i.e., coronary artery bypass graft surgery, percutaneous coronary intervention, cardiac resynchronization therapy, valve surgery or reparation)
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:并行分配
- 屏蔽:三倍
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Eccentric strength training + cardio
45 sessions experimental protocol
|
progressive following protocol, 10min
dynamic strength training + eccentric overload, progressive over time, 3sets*10reps (15-20min)
aerobic training, progressive over time, 10 min
|
|
有源比较器:Traditional strength training + cardio
45 sessions traditional cardiac rehabilitation
|
aerobic training, progressive over time, 10 min
aerobic training, progressive following protocol, 10 min
dynamic strength training, progression over time, 15-20 min
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
1Repetition Maximum (=RM) leg press (kg)
大体时间:pre (baseline) + post (15 weeks)
|
One repetition maximum on leg press device Technogym BioCircuit. The patient is positioned correctly on the leg press (back supported, feet on platform in standardized way so that repeated tests are in the same position). The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single push as the 1RM (kg). |
pre (baseline) + post (15 weeks)
|
|
1Repetition Maximum (=RM) Low Row (kg)
大体时间:pre (baseline) + post (15weeks)
|
One repetition maximum on the low row device Technogym BioCircuit. The patient sits with chest supported, feet on the ground, and grips the handles with arms extended. The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single lift as the 1RM (kg). |
pre (baseline) + post (15weeks)
|
|
1Repetition Maximum (=RM) chest press (kg)
大体时间:pre (baseline) + post (15weeks)
|
One repetition maximum on chest press device Technogym BioCircuit.
The patient is positioned correctly on the chest press (back supported, feet on the ground in standardized way so that repeated tests are in the same position).
The patiënt performes a maximal push, the load is automatically adjusted by the BioCircuit algorithm.
The system identifies the maximum successful single push as the 1RM (kg).
|
pre (baseline) + post (15weeks)
|
|
1Repetition Maximum (=RM) vertical traction (kg)
大体时间:pre (baseline) + post (15weeks)
|
One repetition maximum on vertical traction device Technogym BioCircuit. The patient is positioned correctly on the vertical traction (back supported, feet on the ground in standardized way so that repeated tests are in the same position). The patiënt performes a maximal pull, the load is automatically adjusted by the BioCircuit algorithm. The system identifies the maximum successful single push as the 1RM (kg). |
pre (baseline) + post (15weeks)
|
|
Handgrip strength
大体时间:pre (baseline) + post (15 weeks)
|
The Jamar handgrip dynamometer is used to measure grip strength in a standardized way ( 90° flex elbow, forearm neutral, and wrist slightly extended). 3 trials per hand are performed, with 10seconds rest in between. The average value is recorded as grip strength. |
pre (baseline) + post (15 weeks)
|
|
Isometric Qceps peak torque (Nm)
大体时间:pre (baseline) + post (15weeks)
|
The subject is seated in the Biodex System dynamometer and securely strapped (trunk, pelvis, thigh). The dynamometer axis is aligned with the knee joint axis (lateral femoral epicondyle). The knee is fixed at 60° of flexion (0° = full extension). The lower leg is attached to the lever arm just above the ankle. The subject performs a maximal isometric knee extension (pushing against the immovable arm) for 3seconds. 3 tests are done with 10seconds rest in between. The highest torque value (Nm) recorded is taken as the quadriceps peak torque. |
pre (baseline) + post (15weeks)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
6mwt (m)
大体时间:pre (baseline) - post (15weeks)
|
The 6-minute walk test (6MWT) assesses functional exercise capacity by measuring the distance walked in 6 minutes. It is performed on the same flat, straight corridor (50 meter) with marked turnaround points. The participant is instructed to walk as fast as possible at a self-paced speed. Standardized encouragement is given every minute. A timer is started at the beginning and stopped at 6 minutes. The total distance walked is measured in meters. |
pre (baseline) - post (15weeks)
|
|
Time up and go (s)
大体时间:pre (baseline) + post (15weeks)
|
The participant starts seated in a standard chair (back against the chair, no armrests) On the command "go," the participant stands up, walks 3 meters, turns around, walks back, and sits down again. Timing starts on "go" and stops when the participant is seated again with the back against the chair). The test is performed 3 times (with 20seconds rest in between). The outcome is the mean time taken to complete the 3 tasks (seconds). |
pre (baseline) + post (15weeks)
|
|
VO2 peak (ml/kg/min)
大体时间:pre (baseline) + post (15weeks)
|
VO₂peak is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence(≈60-70 revolutions/min) until volitional exhaustion. Expired gases are analyzed to determine oxygen uptake (VO₂) and carbon dioxide production (VCO₂). Strong verbal encouragement is given to reach maximal effort. VO₂peak is defined as the mean VO₂ value averaged over the final 30 seconds of exercise. Test termination follows symptom limitation or standard clinical safety criteria. |
pre (baseline) + post (15weeks)
|
|
maximal load (Watt)
大体时间:pre (baseline) + post (15weeks)
|
Wattmax is determined during a CPET performed on a Lode Corival ergometer with monitoring via a Vyaire Medical system. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion. Wattmax is defined as the highest workload (in watts) achieved in the final stage. Strong encouragement is provided to achieve maximal effort. |
pre (baseline) + post (15weeks)
|
|
VO2/W slope (ml/min/W)
大体时间:pre (baseline) + post (15weeks)
|
VO2/W slope is measured during a cardiopulmonary exercise test (CPET) on a cycle ergometer. The test is performed on a Lode Corival ergometer with breath-by-breath gas analysis via a Vyaire Medical system. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion. The relationship between VO₂ (y-axis) and work rate (x-axis) is plotted. A linear regression is applied. The slope of this line represents the VO₂/W slope (mL/min/W). |
pre (baseline) + post (15weeks)
|
|
VE/VCO2 slope
大体时间:pre (baseline) + post (15weeks)
|
The VE/VCO₂ slope is measured during CPET on a Lode Corival ergometer with breath-by-breath analysis via Vyaire Medical. After calibration of flow and gas analyzers, the subject is fitted with a mask and monitoring devices (ECG, BP). A short resting phase and unloaded cycling (warm-up) are performed. Workload then increases continuously using an individualized ramp protocol (e.g. 5-20 Watt/min - so small increase every 3-12 seconds). The same protocol is used in the pre and post test. The participant cycles at a constant cadence (≈60-70 revolutions/min) until volitional exhaustion. VE is plotted against VCO₂ over the course of exercise. A linear regression is applied from the start of exercise up to the ventilatory compensation point. The slope of this relationship represents the VE/VCO₂ slope. |
pre (baseline) + post (15weeks)
|
合作者和调查者
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他研究编号
- EDGE 002632
- Belgian Heart Fund (其他赠款/资助编号:King Baudouin Foundation)
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.