Quantifying Adhesive Residue on Skin Following Removal of Maxillofacial Prosthetic Adhesives: An In Vivo Study (ARMS)
A Comparative Assessment of Adhesive Residue on the Skin Following the Removal of Extraoral Silicone Prosthesis: An In Vivo Study
調査の概要
状態
条件
詳細な説明
This pilot interventional in vivo study is designed to quantitatively evaluate and compare the amount of adhesive residue left on the skin following removal of extraoral maxillofacial prosthetic adhesives. Adhesive-retained facial prostheses are widely used in maxillofacial rehabilitation; however, residual adhesive remaining on the skin after prosthesis removal may contribute to patient discomfort, skin irritation, and difficulty in daily prosthesis maintenance. Despite its clinical importance, adhesive residue has not been quantitatively evaluated in vivo.
Five commercially available maxillofacial prosthetic adhesives, including silicone-based and water-based formulations, will be evaluated using standardized silicone elastomer strips. Five healthy volunteers between 18 and 30 years of age will be recruited. Thirty test sites will be prepared on the volar surfaces of the forearms, with six sites allocated to each adhesive group through block randomization. Participants with skin diseases, adhesive allergies, systemic conditions affecting skin integrity, pregnancy, lactation, or recent skin injuries will be excluded.
Standardized silicone strips measuring 60 × 20 × 3 mm will be fabricated and coated with a uniform quantity of adhesive. After a drying period of 3 minutes, the strips will be applied to designated skin sites and maintained for 8 hours during normal daily activities. Following removal, the strips will be reweighed using a high-precision analytical balance. Adhesive residue remaining on the skin will be quantified using gravimetric analysis by calculating the percentage difference between initial and final strip weights.
The primary outcome measure is the percentage of adhesive residue remaining on the skin after removal of the prosthetic adhesive. Secondary objectives include assessment of adhesive failure modes and comparison of residue patterns between silicone-based and water-based adhesive systems.
To minimize bias, participant allocation sites will be randomized and both participants and investigators involved in application and evaluation procedures will remain blinded to adhesive identity. Statistical analysis will be performed using one-way analysis of variance followed by post hoc multiple comparison testing. The findings of this study may help clinicians select adhesive systems that optimize prosthesis retention while minimizing skin trauma and patient burden during long-term maxillofacial rehabilitation.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Kerala
-
Kochi、Kerala、インド、682041
- Amrita School of Dentistry, Amrita Institute of Medical Sciences, Kochi, Kerala, India
-
-
参加基準
適格基準
就学可能な年齢
- 大人
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Healthy volunteers aged 18-30 years
- Willingness to participate and provide written informed consent
- No history of skin disease
- No known adhesive allergy
Exclusion Criteria:
- Age below 18 years or above 30 years
- Current use of medications affecting skin integrity or immune function
- Recent skin trauma, surgery, or active skin lesions
- Existing systemic disease affecting skin health
- Pre-existing dermatological conditions
- Pregnancy or lactation
- Known allergy or hypersensitivity to adhesives or silicone materials
- Participation in another clinical trial during the study period
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Adhesive Evaluation Group
All participants receive applications of five commercially available maxillofacial prosthetic adhesives at randomized skin sites on the volar forearms using standardized silicone strips.
Adhesive residue remaining on the skin after 8 hours of wear is quantitatively evaluated using gravimetric analysis.
|
Silicone-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.
Silicone-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.
Water-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.
Water-based maxillofacial prosthetic adhesive (Factor II Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.
Water-based maxillofacial prosthetic adhesive (ADM Tronics Inc., USA) evaluated for adhesive residue remaining on skin following removal of standardized silicone strips after 8 hours of wear.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Percentage of adhesive residue remaining on skin after 8 hours
時間枠:8 hours
|
Quantitative assessment of adhesive residue remaining on the skin after removal of standardized silicone strips coated with maxillofacial prosthetic adhesives using gravimetric analysis.
|
8 hours
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Adhesive Failure Mode Classification
時間枠:8 hours
|
Assessment of adhesive failure mode following removal of the silicone strip. Failure mode will be classified as:
Classification will be performed by visual inspection of the skin and silicone strip after removal. |
8 hours
|
|
Time Required for Complete Adhesive Removal (Cleanability Assessment)
時間枠:8 hours
|
Cleanability will be assessed by measuring the time (in seconds) required to completely remove residual adhesive from the skin using a standardized cleaning procedure.
Lower cleaning times indicate greater cleanability.
|
8 hours
|
|
Comparison of Adhesive Residue Between Silicone-Based and Water-Based Adhesives
時間枠:8 hours
|
Comparison of percentage adhesive residue remaining on skin between silicone-based and water-based adhesive formulations, measured using gravimetric analysis.
|
8 hours
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- McNichol L, Lund C, Rosen T, Gray M. Medical adhesives and patient safety: state of the science: consensus statements for the assessment, prevention, and treatment of adhesive-related skin injuries. Orthop Nurs. 2013 Sep-Oct;32(5):267-81. doi: 10.1097/NOR.0b013e3182a39caf.
- Rajasekaran R, Chander NG, Reddy JR, Balasubramanium M. Estimation of differences and reapplication effect of peel bond strength between silicone-based and water-based adhesives. J Prosthet Dent. 2024 Jun;131(6):1276-1279. doi: 10.1016/j.prosdent.2022.05.024. Epub 2022 Jun 25.
- Kiat-amnuay S, Gettleman L, Khan Z, Goldsmith LJ. Effect of adhesive retention on maxillofacial prostheses. Part I: skin dressings and solvent removers. J Prosthet Dent. 2000 Sep;84(3):335-40. doi: 10.1067/mpr.2000.109507.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
その他の研究ID番号
- ECASM-AIMS-2024-085
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。