このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Light Therapy for University Students

2026年6月22日 更新者:Birna Baldursdottir、Reykjavik University

Effects of Light Therapy on Well-being of University Students: A Pilot Study

The effects of light therapy on well-being among university students was investigated. A three-week intervention study examined whether the use of light glasses improved sleep quality and concentration and reduced symptoms of depression and anxiety among university students. First, a questionnaire was administered to about 130 students to screen for sleep problems. Based on the responses, those with the most sleep problems were invited to participate in the intervention study, which resulted in 39 participants in total. Although studies of light therapy for sleep problems and depression among patients have yielded positive results, the use of light has not been studied much among healthy individuals. The intervention study used glasses that project light in two intensities and participants were randomized into two groups with different intensities of light. The aim of the study was to: a) compare the effects of different light intensities on sleep and concentration and b) investigate whether light therapy influences symptoms of depression and anxiety among university students. The study is expected to increase knowledge of light therapy among healthy individuals, and if the treatment proves successful, it is an easy and inexpensive way to increase well-being among university students.

調査の概要

研究の種類

介入

入学 (実際)

39

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

      • Reykjavik、アイスランド、102
        • Department of Psychology, Reykjavík University

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Being a psychology student at Reykjavik University, Iceland
  • Able to understand, read and write Icelandic
  • At screening assessment prior to the intervention, demonstrating a score of three or above on any of the six items of the BIS scale, thereby including students who showed even mild symptoms of sleep problems

Exclusion Criteria:

  • Not being a psychology student at Reykjavik University, Iceland
  • Not able to understand, read and write Icelandic
  • Demonstrating a score below three on all of the six items of the BIS scale

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:処理
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:ダブル

武器と介入

参加者グループ / アーム
介入・治療
実験的:Blue Light Therapy
Exposure of experimental circadian-effective blue light (BL) by glasses for 30 minutes each morning during the 3-week intervention

The circadian-effective light glasses used by the experimental group (BL) emitted narrowband (peak lambda = 470 nm) blue light with an irradiance of 250 μW/cm2 (120 lux).

The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light.

Brand: AYO glasses.

アクティブコンパレータ:Dim Light Therapy
Exposure of experimental comparison circadian-ineffective dim light (DL) by glasses for 30 minutes each morning during the 3-week intervention

The circadian-ineffective sham glasses (DL) emitted blue light with an irradiance of 2.5 μW/cm2 (1.16 lux).

The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light.

Brand: AYO glasses.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
The Bergen Insomnia Scale (BIS)
時間枠:BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
The Bergen Insomnia Scale (BIS) is a short scale on sleep habits consisting of six items pertaining to sleep onset, maintenance, early morning wakening, restorative sleep, daytime functioning, and sleep satisfaction. Responses indicate how often sleep problems, according to the six items, are experienced during the last month on an 8-point scale (0-7 days per week) with a range between 0 and 42, where a higher score suggests more sleep problems.
BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
The Pittsburgh Sleep Quality Index (PSQI)
時間枠:PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
The Pittsburgh Sleep Quality Index (PSQI) consists of 19 self-rated items about sleep habits during the last month. The questions are categorised into seven components, rated from 0 to 3, evaluating sleep duration, quality, and latency as well as habitual sleep efficiency, sleep disturbances, usage of sleep medication, and daytime dysfunction. A global PSQI score, ranging from 0 to 21, is calculated by summarising the seven components' scores, where a higher global score indicates worse sleep quality and a score above five suggests poor sleep quality.
PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
Objective sleep measure by actigraphy: Total time in bed
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Total time in bed, measured as minutes.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Total sleep time
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Total sleep time, measured as minutes.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Sleep latency
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Sleep latency, measured as minutes.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Wake after sleep onset
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Wake after sleep onset, measured as minutes.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Number of awakenings
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Number of awakenings, measured as number of awakenings per sleep period.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Sleep fragmentation index
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Sleep fragmentation index, measured as percentage.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Sleep movement index
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Sleep movement index, measured as events per hour.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Objective sleep measure by actigraphy: Sleep efficiency
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep. Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software. Parameter measured: Sleep efficiency, measured as percentage.
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).

二次結果の測定

結果測定
メジャーの説明
時間枠
The Center for Epidemiological Studies Depression Scale (CES-D)
時間枠:CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
The Center for Epidemiological Studies Depression Scale (CES-D) is a 20 item self-report instrument, designed to measure common symptoms of depression that have occurred over the past week such as poor appetite, hopelessness, pessimism, and fatigue. Response options range from 0 to 3 for each item. Scores range from 0 to 60, with high scores indicating greater depressive symptoms.
CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
General Anxiety Disorder (GAD-7)
時間枠:GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
General Anxiety Disorder (GAD-7) is a shorter version of the original GAD-13 item scale designed to measure anxiety. Each of the seven questions is rated on a 4-point Likert scale based on symptom frequency. The total score is calculated by summing the scores for all seven items, thus scores range from 0 to 21, with higer score meaning more anxiety. Cut-points are as follows: 0-4: Minimal anxiety, 5-9: Mild anxiety, 10-14: Moderate anxiety, and 15-21: Severe anxiety. A score of 10 or greater is often used as a clinical cut-off point.
GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ)
時間枠:rMEQ was administered at baseline (day 1).
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ) is a self-report questionnaire is one of the most widely used questionnaire to measure chronotype. The rMEQ consists of 5 questions that assess an individual's preference for morning or evening activities. Based on results from the scoring, individuals can be categorized as: Morning Types: Prefer morning activities; Evening Types: Prefer evening activities or Intermediate Types: Have no strong preference.
rMEQ was administered at baseline (day 1).
The Epworth Sleepiness Scale (ESS)
時間枠:ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
The Epworth Sleepiness Scale (ESS) is widely used in sleep research and clinical settings and consists of 8 questions (each with 4 answering possibilities) about sleepiness. measure a person's likelihood of dozing off during various daily activities. ESS provides a score ranging from 0 to 24, with higher scores indicating excessive daytime sleepiness. In general ESS scores can be interpreted as follows: 0-5 Lower Normal Daytime Sleepiness; 6-10 Higher Normal Daytime Sleepiness; 11-12 Mild Excessive Daytime Sleepiness; 13-15 Moderate Excessive Daytime Sleepiness; and 16-24 Severe Excessive Daytime Sleepiness.
ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
Objective measures of cognitive performance: Operation Span (Ospan)
時間枠:Ospan was administered at baseline (day 1) and FU2 (day 21).
Three neuropsychological tests were used to measure cognitive performance: Operation Span (Ospan) is a cognitive task designed to measure working memory capacity by requiring participants to remember sequences of letters while simultaneously solving simple math problems. This dual-task approach assesses how well individuals can manage their memory resources under distraction.
Ospan was administered at baseline (day 1) and FU2 (day 21).
Objective measures of cognitive performance: Digit span forward
時間枠:Digit span forward was administered at baseline (day 1) and FU2 (day 21).
Three neuropsychological tests were used to measure cognitive performance: Digit span forward is a cognitive task where a person listens to a sequence of numbers and then repeats them back in the same order. This task primarily measures short-term auditory memory and is commonly used in psychological assessments to evaluate working memory capacity.
Digit span forward was administered at baseline (day 1) and FU2 (day 21).
Objective measures of cognitive performance: Digit span backward
時間枠:Digit span backward was administered at baseline (day 1) and FU2 (day 21).
Three neuropsychological tests were used to measure cognitive performance: Digit span backward is a cognitive task that measures short-term memory by requiring participants to recall a sequence of numbers in reverse order. This task is more challenging than recalling the numbers in the original order, as it involves both storage and manipulation of the information.
Digit span backward was administered at baseline (day 1) and FU2 (day 21).

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • 主任研究者:Birna Baldursdottir, PhD、Reykjavík University, Iceland

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2019年3月6日

一次修了 (実際)

2019年4月8日

研究の完了 (実際)

2019年4月8日

試験登録日

最初に提出

2026年5月29日

QC基準を満たした最初の提出物

2026年6月15日

最初の投稿 (実際)

2026年6月22日

学習記録の更新

投稿された最後の更新 (実際)

2026年6月25日

QC基準を満たした最後の更新が送信されました

2026年6月22日

最終確認日

2026年6月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

はい

IPD プランの説明

IPD will be shared upon reasoned requests.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する