Light Therapy for University Students
Effects of Light Therapy on Well-being of University Students: A Pilot Study
調査の概要
状態
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
-
Reykjavik、アイスランド、102
- Department of Psychology, Reykjavík University
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Being a psychology student at Reykjavik University, Iceland
- Able to understand, read and write Icelandic
- At screening assessment prior to the intervention, demonstrating a score of three or above on any of the six items of the BIS scale, thereby including students who showed even mild symptoms of sleep problems
Exclusion Criteria:
- Not being a psychology student at Reykjavik University, Iceland
- Not able to understand, read and write Icelandic
- Demonstrating a score below three on all of the six items of the BIS scale
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Blue Light Therapy
Exposure of experimental circadian-effective blue light (BL) by glasses for 30 minutes each morning during the 3-week intervention
|
The circadian-effective light glasses used by the experimental group (BL) emitted narrowband (peak lambda = 470 nm) blue light with an irradiance of 250 μW/cm2 (120 lux). The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light. Brand: AYO glasses. |
|
アクティブコンパレータ:Dim Light Therapy
Exposure of experimental comparison circadian-ineffective dim light (DL) by glasses for 30 minutes each morning during the 3-week intervention
|
The circadian-ineffective sham glasses (DL) emitted blue light with an irradiance of 2.5 μW/cm2 (1.16 lux). The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light. Brand: AYO glasses. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The Bergen Insomnia Scale (BIS)
時間枠:BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
|
The Bergen Insomnia Scale (BIS) is a short scale on sleep habits consisting of six items pertaining to sleep onset, maintenance, early morning wakening, restorative sleep, daytime functioning, and sleep satisfaction.
Responses indicate how often sleep problems, according to the six items, are experienced during the last month on an 8-point scale (0-7 days per week) with a range between 0 and 42, where a higher score suggests more sleep problems.
|
BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
|
|
The Pittsburgh Sleep Quality Index (PSQI)
時間枠:PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
|
The Pittsburgh Sleep Quality Index (PSQI) consists of 19 self-rated items about sleep habits during the last month.
The questions are categorised into seven components, rated from 0 to 3, evaluating sleep duration, quality, and latency as well as habitual sleep efficiency, sleep disturbances, usage of sleep medication, and daytime dysfunction.
A global PSQI score, ranging from 0 to 21, is calculated by summarising the seven components' scores, where a higher global score indicates worse sleep quality and a score above five suggests poor sleep quality.
|
PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
|
|
Objective sleep measure by actigraphy: Total time in bed
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Total time in bed, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Total sleep time
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Total sleep time, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep latency
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep latency, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Wake after sleep onset
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Wake after sleep onset, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Number of awakenings
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Number of awakenings, measured as number of awakenings per sleep period.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep fragmentation index
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep fragmentation index, measured as percentage.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep movement index
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep movement index, measured as events per hour.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep efficiency
時間枠:Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep efficiency, measured as percentage.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
The Center for Epidemiological Studies Depression Scale (CES-D)
時間枠:CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
The Center for Epidemiological Studies Depression Scale (CES-D) is a 20 item self-report instrument, designed to measure common symptoms of depression that have occurred over the past week such as poor appetite, hopelessness, pessimism, and fatigue.
Response options range from 0 to 3 for each item.
Scores range from 0 to 60, with high scores indicating greater depressive symptoms.
|
CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
General Anxiety Disorder (GAD-7)
時間枠:GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
General Anxiety Disorder (GAD-7) is a shorter version of the original GAD-13 item scale designed to measure anxiety.
Each of the seven questions is rated on a 4-point Likert scale based on symptom frequency.
The total score is calculated by summing the scores for all seven items, thus scores range from 0 to 21, with higer score meaning more anxiety.
Cut-points are as follows: 0-4: Minimal anxiety, 5-9: Mild anxiety, 10-14: Moderate anxiety, and 15-21: Severe anxiety.
A score of 10 or greater is often used as a clinical cut-off point.
|
GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ)
時間枠:rMEQ was administered at baseline (day 1).
|
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ) is a self-report questionnaire is one of the most widely used questionnaire to measure chronotype.
The rMEQ consists of 5 questions that assess an individual's preference for morning or evening activities.
Based on results from the scoring, individuals can be categorized as: Morning Types: Prefer morning activities; Evening Types: Prefer evening activities or Intermediate Types: Have no strong preference.
|
rMEQ was administered at baseline (day 1).
|
|
The Epworth Sleepiness Scale (ESS)
時間枠:ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
The Epworth Sleepiness Scale (ESS) is widely used in sleep research and clinical settings and consists of 8 questions (each with 4 answering possibilities) about sleepiness.
measure a person's likelihood of dozing off during various daily activities.
ESS provides a score ranging from 0 to 24, with higher scores indicating excessive daytime sleepiness.
In general ESS scores can be interpreted as follows: 0-5 Lower Normal Daytime Sleepiness; 6-10 Higher Normal Daytime Sleepiness; 11-12 Mild Excessive Daytime Sleepiness; 13-15 Moderate Excessive Daytime Sleepiness; and 16-24 Severe Excessive Daytime Sleepiness.
|
ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Operation Span (Ospan)
時間枠:Ospan was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Operation Span (Ospan) is a cognitive task designed to measure working memory capacity by requiring participants to remember sequences of letters while simultaneously solving simple math problems.
This dual-task approach assesses how well individuals can manage their memory resources under distraction.
|
Ospan was administered at baseline (day 1) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Digit span forward
時間枠:Digit span forward was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Digit span forward is a cognitive task where a person listens to a sequence of numbers and then repeats them back in the same order.
This task primarily measures short-term auditory memory and is commonly used in psychological assessments to evaluate working memory capacity.
|
Digit span forward was administered at baseline (day 1) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Digit span backward
時間枠:Digit span backward was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Digit span backward is a cognitive task that measures short-term memory by requiring participants to recall a sequence of numbers in reverse order.
This task is more challenging than recalling the numbers in the original order, as it involves both storage and manipulation of the information.
|
Digit span backward was administered at baseline (day 1) and FU2 (day 21).
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Birna Baldursdottir, PhD、Reykjavík University, Iceland
出版物と役立つリンク
一般刊行物
- Buysse DJ, Reynolds CF 3rd, Monk TH, Berman SR, Kupfer DJ. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989 May;28(2):193-213. doi: 10.1016/0165-1781(89)90047-4.
- Spitzer RL, Kroenke K, Williams JB, Lowe B. A brief measure for assessing generalized anxiety disorder: the GAD-7. Arch Intern Med. 2006 May 22;166(10):1092-7. doi: 10.1001/archinte.166.10.1092.
- Johns MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep. 1991 Dec;14(6):540-5. doi: 10.1093/sleep/14.6.540.
- Pallesen S, Bjorvatn B, Nordhus IH, Sivertsen B, Hjornevik M, Morin CM. A new scale for measuring insomnia: the Bergen Insomnia Scale. Percept Mot Skills. 2008 Dec;107(3):691-706. doi: 10.2466/pms.107.3.691-706.
- Radloff, L. S. (1977). The CES-D Scale: A Self-Report Depression Scale for Research in the General Population. Applied Psychological Measurement, 1(3), 385-401. doi:10.1177/014662167700100306
- Danielsson K, Sakarya A, Jansson-Frojmark M. The reduced Morningness-Eveningness Questionnaire: Psychometric properties and related factors in a young Swedish population. Chronobiol Int. 2019 Apr;36(4):530-540. doi: 10.1080/07420528.2018.1564322. Epub 2019 Jan 7.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは