- ICH GCP
- Rejestr badań klinicznych w USA
- Badanie kliniczne NCT07659171
Light Therapy for University Students
Effects of Light Therapy on Well-being of University Students: A Pilot Study
Przegląd badań
Status
Interwencja / Leczenie
Typ studiów
Zapisy (Rzeczywisty)
Faza
- Nie dotyczy
Kontakty i lokalizacje
Lokalizacje studiów
-
-
-
Reykjavik, Islandia, 102
- Department of Psychology, Reykjavík University
-
-
Kryteria uczestnictwa
Kryteria kwalifikacji
Wiek uprawniający do nauki
- Dorosły
- Starszy dorosły
Akceptuje zdrowych ochotników
Opis
Inclusion Criteria:
- Being a psychology student at Reykjavik University, Iceland
- Able to understand, read and write Icelandic
- At screening assessment prior to the intervention, demonstrating a score of three or above on any of the six items of the BIS scale, thereby including students who showed even mild symptoms of sleep problems
Exclusion Criteria:
- Not being a psychology student at Reykjavik University, Iceland
- Not able to understand, read and write Icelandic
- Demonstrating a score below three on all of the six items of the BIS scale
Plan studiów
Jak projektuje się badanie?
Szczegóły projektu
- Główny cel: Leczenie
- Przydział: Randomizowane
- Model interwencyjny: Przydział równoległy
- Maskowanie: Podwójnie
Broń i interwencje
Grupa uczestników / Arm |
Interwencja / Leczenie |
|---|---|
|
Eksperymentalny: Blue Light Therapy
Exposure of experimental circadian-effective blue light (BL) by glasses for 30 minutes each morning during the 3-week intervention
|
The circadian-effective light glasses used by the experimental group (BL) emitted narrowband (peak lambda = 470 nm) blue light with an irradiance of 250 μW/cm2 (120 lux). The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light. Brand: AYO glasses. |
|
Aktywny komparator: Dim Light Therapy
Exposure of experimental comparison circadian-ineffective dim light (DL) by glasses for 30 minutes each morning during the 3-week intervention
|
The circadian-ineffective sham glasses (DL) emitted blue light with an irradiance of 2.5 μW/cm2 (1.16 lux). The light glasses emit light from LEDs at a distance of 15 millimeters (15mm, 0.015.) from the eye. The device is classified as safe for the eyes in accordance with the international standard IEC 62471 and complies with the United States of America's FCC marking, and is designed to be worn on the participant's head, similar to a pair of regular glasses. For safety purposes, the light glasses do not contain UV or infra-red light. Brand: AYO glasses. |
Co mierzy badanie?
Podstawowe miary wyniku
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
The Bergen Insomnia Scale (BIS)
Ramy czasowe: BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
|
The Bergen Insomnia Scale (BIS) is a short scale on sleep habits consisting of six items pertaining to sleep onset, maintenance, early morning wakening, restorative sleep, daytime functioning, and sleep satisfaction.
Responses indicate how often sleep problems, according to the six items, are experienced during the last month on an 8-point scale (0-7 days per week) with a range between 0 and 42, where a higher score suggests more sleep problems.
|
BIS was used to screen for sleep-related problems, prior to the intervention, at baseline (day 1), at the middle of intervention (FU1, day 11) and at the of intervention (FU2, day 21).
|
|
The Pittsburgh Sleep Quality Index (PSQI)
Ramy czasowe: PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
|
The Pittsburgh Sleep Quality Index (PSQI) consists of 19 self-rated items about sleep habits during the last month.
The questions are categorised into seven components, rated from 0 to 3, evaluating sleep duration, quality, and latency as well as habitual sleep efficiency, sleep disturbances, usage of sleep medication, and daytime dysfunction.
A global PSQI score, ranging from 0 to 21, is calculated by summarising the seven components' scores, where a higher global score indicates worse sleep quality and a score above five suggests poor sleep quality.
|
PSQI was administered at baseline (day 1), FU1 (day 11), and FU2 (day 21).
|
|
Objective sleep measure by actigraphy: Total time in bed
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Total time in bed, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Total sleep time
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Total sleep time, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep latency
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep latency, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Wake after sleep onset
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Wake after sleep onset, measured as minutes.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Number of awakenings
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Number of awakenings, measured as number of awakenings per sleep period.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep fragmentation index
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep fragmentation index, measured as percentage.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep movement index
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep movement index, measured as events per hour.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
|
Objective sleep measure by actigraphy: Sleep efficiency
Ramy czasowe: Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Wrist-worn actigraphy devices (model GT3X+ ActiSleep) were used to objectively measure sleep.
Sleep parameters were calculated using the Cole-Kripke sleep algorithm in the ActiLife 6 data analysis software.
Parameter measured: Sleep efficiency, measured as percentage.
|
Participants were asked to wear the devices on their non-dominant arm for four consecutive days, both at baseline (day 1-4) and at FU2 (day 18-21).
|
Miary wyników drugorzędnych
Miara wyniku |
Opis środka |
Ramy czasowe |
|---|---|---|
|
The Center for Epidemiological Studies Depression Scale (CES-D)
Ramy czasowe: CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
The Center for Epidemiological Studies Depression Scale (CES-D) is a 20 item self-report instrument, designed to measure common symptoms of depression that have occurred over the past week such as poor appetite, hopelessness, pessimism, and fatigue.
Response options range from 0 to 3 for each item.
Scores range from 0 to 60, with high scores indicating greater depressive symptoms.
|
CES-D was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
General Anxiety Disorder (GAD-7)
Ramy czasowe: GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
General Anxiety Disorder (GAD-7) is a shorter version of the original GAD-13 item scale designed to measure anxiety.
Each of the seven questions is rated on a 4-point Likert scale based on symptom frequency.
The total score is calculated by summing the scores for all seven items, thus scores range from 0 to 21, with higer score meaning more anxiety.
Cut-points are as follows: 0-4: Minimal anxiety, 5-9: Mild anxiety, 10-14: Moderate anxiety, and 15-21: Severe anxiety.
A score of 10 or greater is often used as a clinical cut-off point.
|
GAD-7 was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ)
Ramy czasowe: rMEQ was administered at baseline (day 1).
|
The reduced Horne & Östberg Morningness-Eveningness Questionnaire (rMEQ) is a self-report questionnaire is one of the most widely used questionnaire to measure chronotype.
The rMEQ consists of 5 questions that assess an individual's preference for morning or evening activities.
Based on results from the scoring, individuals can be categorized as: Morning Types: Prefer morning activities; Evening Types: Prefer evening activities or Intermediate Types: Have no strong preference.
|
rMEQ was administered at baseline (day 1).
|
|
The Epworth Sleepiness Scale (ESS)
Ramy czasowe: ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
The Epworth Sleepiness Scale (ESS) is widely used in sleep research and clinical settings and consists of 8 questions (each with 4 answering possibilities) about sleepiness.
measure a person's likelihood of dozing off during various daily activities.
ESS provides a score ranging from 0 to 24, with higher scores indicating excessive daytime sleepiness.
In general ESS scores can be interpreted as follows: 0-5 Lower Normal Daytime Sleepiness; 6-10 Higher Normal Daytime Sleepiness; 11-12 Mild Excessive Daytime Sleepiness; 13-15 Moderate Excessive Daytime Sleepiness; and 16-24 Severe Excessive Daytime Sleepiness.
|
ESS was administered at baseline (day 1), FU1 (day 11) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Operation Span (Ospan)
Ramy czasowe: Ospan was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Operation Span (Ospan) is a cognitive task designed to measure working memory capacity by requiring participants to remember sequences of letters while simultaneously solving simple math problems.
This dual-task approach assesses how well individuals can manage their memory resources under distraction.
|
Ospan was administered at baseline (day 1) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Digit span forward
Ramy czasowe: Digit span forward was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Digit span forward is a cognitive task where a person listens to a sequence of numbers and then repeats them back in the same order.
This task primarily measures short-term auditory memory and is commonly used in psychological assessments to evaluate working memory capacity.
|
Digit span forward was administered at baseline (day 1) and FU2 (day 21).
|
|
Objective measures of cognitive performance: Digit span backward
Ramy czasowe: Digit span backward was administered at baseline (day 1) and FU2 (day 21).
|
Three neuropsychological tests were used to measure cognitive performance: Digit span backward is a cognitive task that measures short-term memory by requiring participants to recall a sequence of numbers in reverse order.
This task is more challenging than recalling the numbers in the original order, as it involves both storage and manipulation of the information.
|
Digit span backward was administered at baseline (day 1) and FU2 (day 21).
|
Współpracownicy i badacze
Sponsor
Współpracownicy
Śledczy
- Główny śledczy: Birna Baldursdottir, PhD, Reykjavík University, Iceland
Publikacje i pomocne linki
Publikacje ogólne
- Buysse DJ, Reynolds CF 3rd, Monk TH, Berman SR, Kupfer DJ. The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research. Psychiatry Res. 1989 May;28(2):193-213. doi: 10.1016/0165-1781(89)90047-4.
- Spitzer RL, Kroenke K, Williams JB, Lowe B. A brief measure for assessing generalized anxiety disorder: the GAD-7. Arch Intern Med. 2006 May 22;166(10):1092-7. doi: 10.1001/archinte.166.10.1092.
- Johns MW. A new method for measuring daytime sleepiness: the Epworth sleepiness scale. Sleep. 1991 Dec;14(6):540-5. doi: 10.1093/sleep/14.6.540.
- Pallesen S, Bjorvatn B, Nordhus IH, Sivertsen B, Hjornevik M, Morin CM. A new scale for measuring insomnia: the Bergen Insomnia Scale. Percept Mot Skills. 2008 Dec;107(3):691-706. doi: 10.2466/pms.107.3.691-706.
- Radloff, L. S. (1977). The CES-D Scale: A Self-Report Depression Scale for Research in the General Population. Applied Psychological Measurement, 1(3), 385-401. doi:10.1177/014662167700100306
- Danielsson K, Sakarya A, Jansson-Frojmark M. The reduced Morningness-Eveningness Questionnaire: Psychometric properties and related factors in a young Swedish population. Chronobiol Int. 2019 Apr;36(4):530-540. doi: 10.1080/07420528.2018.1564322. Epub 2019 Jan 7.
Daty zapisu na studia
Główne daty studiów
Rozpoczęcie studiów (Rzeczywisty)
Zakończenie podstawowe (Rzeczywisty)
Ukończenie studiów (Rzeczywisty)
Daty rejestracji na studia
Pierwszy przesłany
Pierwszy przesłany, który spełnia kryteria kontroli jakości
Pierwszy wysłany (Rzeczywisty)
Aktualizacje rekordów badań
Ostatnia wysłana aktualizacja (Rzeczywisty)
Ostatnia przesłana aktualizacja, która spełniała kryteria kontroli jakości
Ostatnia weryfikacja
Więcej informacji
Terminy związane z tym badaniem
Słowa kluczowe
Dodatkowe istotne warunki MeSH
Inne numery identyfikacyjne badania
- VSN-19054
Plan dla danych uczestnika indywidualnego (IPD)
Planujesz udostępniać dane poszczególnych uczestników (IPD)?
Opis planu IPD
Informacje o lekach i urządzeniach, dokumenty badawcze
Bada produkt leczniczy regulowany przez amerykańską FDA
Bada produkt urządzenia regulowany przez amerykańską FDA
Te informacje zostały pobrane bezpośrednio ze strony internetowej clinicaltrials.gov bez żadnych zmian. Jeśli chcesz zmienić, usunąć lub zaktualizować dane swojego badania, skontaktuj się z register@clinicaltrials.gov. Gdy tylko zmiana zostanie wprowadzona na stronie clinicaltrials.gov, zostanie ona automatycznie zaktualizowana również na naszej stronie internetowej .