Randomized Cross-Over Comparison of Medium Cut-Off and High-Flux Hemodialysis Membranes (MCO-HD)
Randomized Cross-Over Evaluation of Medium Cut-Off and High-Flux Hemodialysis Membranes on Inflammation and Cardiovascular Function in Maintenance Hemodialysis Patients
Patients receiving maintenance hemodialysis are at increased risk of cardiovascular disease, chronic inflammation, endothelial dysfunction, and impaired quality of life. Medium cut-Off (MCO) hemodialysis membranes have been developed to enhance the removal of middle-molecular-weight uremic toxins compared with conventional high-flux membranes, which may improve inflammatory status and cardiovascular health.
The aim of this study is to compare the effects of MCO and high-flux hemodialysis membranes on inflammatory biomarkers and cardiovascular function in adult patients receiving maintenance hemodialysis. The primary outcomes are changes in serum interleukin-6 (IL-6) and vascular cell adhesion molecule-1 (VCAM-1) levels. Secondary outcomes include arterial stiffness assessed by pulse wave velocity (PWV), body composition assessed by Body Composition Monitor (BCM), handgrip strength, and patient-reported outcomes including quality of life, pruritus, and pain scores.
This is a prospective, randomized, open-label, two-sequence, two-period crossover study conducted at Gazi University Faculty of Medicine. Thirty adult hemodialysis patients will be randomized to one of two treatment sequences. Participants in Sequence A will receive MCO dialysis membranes for the first 3 months followed by high-flux membranes for the next 3 months. Participants in Sequence B will receive high-flux membranes for the first 3 months followed by MCO membranes for the next 3 months. Blood samples and clinical assessments will be performed at baseline, month 3, and month 6.
The study is expected to provide evidence regarding the effects of different dialysis membrane technologies on inflammation and cardiovascular health and may contribute to optimizing membrane selection in routine hemodialysis practice.
調査の概要
状態
詳細な説明
Cardiovascular disease remains the leading cause of morbidity and mortality in patients receiving maintenance hemodialysis. Chronic inflammation, endothelial dysfunction, vascular stiffness, and the accumulation of middle-molecular-weight uremic toxins are considered important contributors to adverse cardiovascular outcomes in this population. Conventional high-flux hemodialysis membranes provide effective small-solute clearance but have limited capacity for removing larger middle molecules involved in inflammation and vascular injury.
Medium cut-off (MCO) membranes have been developed to enhance the clearance of larger middle molecules while maintaining albumin retention within acceptable limits. Previous studies have suggested that MCO membranes may improve inflammatory profiles and patient-centered outcomes; however, data regarding their effects on endothelial dysfunction, arterial stiffness, body composition, and patient-reported outcomes remain limited.
This study is designed as a prospective, randomized, open-label, two-sequence, two-period crossover clinical investigation comparing MCO and high-flux hemodialysis membranes in maintenance hemodialysis patients. Participants will be randomized in a 1:1 ratio to one of two treatment sequences. Sequence A will receive MCO membranes during Period 1 (Months 0-3) followed by high-flux membranes during Period 2 (Months 3-6). Sequence B will receive high-flux membranes during Period 1 followed by MCO membranes during Period 2. This crossover design allows each participant to serve as his or her own control, thereby reducing inter-individual variability.
Study assessments will be performed at baseline, Month 3, and Month 6. In addition to routine laboratory testing performed during standard hemodialysis follow-up, blood samples will be obtained at baseline, Month 3, and Month 6 for the measurement of serum interleukin-6 (IL-6) and vascular cell adhesion molecule-1 (VCAM-1). Cardiovascular assessment will include pulse wave velocity (PWV) measurement. Nutritional and body composition status will be evaluated using Body Composition Monitor (BCM) parameters, including overhydration, ECW/TBW ratio, intracellular water, lean tissue index, body cell mass, and phase angle. Functional status will be assessed by handgrip strength measurement. Patient-reported outcomes will be evaluated using the Kidney Disease Quality of Life-36 (KDQOL-36), UP-Dial pruritus questionnaire, and Short-Form McGill Pain Questionnaire (SF-MPQ).
The primary objective is to compare the effects of MCO and high-flux membranes on IL-6 and VCAM-1 levels. Secondary objectives include evaluation of arterial stiffness, body composition, physical function, and patient-reported outcomes. The findings may provide clinically relevant evidence regarding membrane selection strategies in routine hemodialysis practice.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Ankara
-
Ankara、Ankara、トルコ(Türkiye)、06500
- Gazi University Faculty of Medicine, Department of Nephrology, Hemodialysis Unit
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Age 18 to 80 years.
- Receiving maintenance hemodialysis for at least 6 months.
- Clinically stable and receiving thrice-weekly hemodialysis.
- Able to comply with study procedures, questionnaires, and scheduled assessments.
- Able and willing to provide written informed consent.
Exclusion Criteria:
- Acute infection at screening or enrollment.
- Major surgery within the previous 3 months.
- Active malignancy requiring ongoing treatment.
- Terminal illness with limited life expectancy.
- Physical or cognitive impairment preventing completion of study procedures or questionnaires.
- Inability or unwillingness to provide written informed consent.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:クロスオーバー割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Sequence A (MCO to High-Flux)
Participants randomized to Sequence A will receive medium cut-off (MCO) hemodialysis membranes during Period 1 (Months 0-3), followed by high-flux hemodialysis membranes during Period 2 (Months 3-6).
Hemodialysis will be performed three times weekly according to standard clinical practice.
Clinical, laboratory, and patient-reported outcome assessments will be performed at baseline, Month 3, and Month 6.
|
Medium cut-off (MCO) hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
MCO membranes are designed to enhance the clearance of larger middle-molecular-weight uremic toxins while maintaining clinically acceptable albumin retention.
Participants assigned to MCO treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, MCO treatment will be delivered using the ELISIO™ MCO series (Nipro).
High-flux hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
High-flux membranes represent the current standard dialysis technology and provide effective clearance of small solutes and selected middle molecules.
Participants assigned to high-flux treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, high-flux treatment will be delivered using the ELISIO™ HF series (Nipro).
|
|
実験的:Sequence B (High-Flux to MCO)
Participants randomized to Sequence B will receive high-flux hemodialysis membranes during Period 1 (Months 0-3), followed by medium cut-off (MCO) hemodialysis membranes during Period 2 (Months 3-6).
Hemodialysis will be performed three times weekly according to standard clinical practice.
Clinical, laboratory, and patient-reported outcome assessments will be performed at baseline, Month 3, and Month 6.
|
Medium cut-off (MCO) hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
MCO membranes are designed to enhance the clearance of larger middle-molecular-weight uremic toxins while maintaining clinically acceptable albumin retention.
Participants assigned to MCO treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, MCO treatment will be delivered using the ELISIO™ MCO series (Nipro).
High-flux hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
High-flux membranes represent the current standard dialysis technology and provide effective clearance of small solutes and selected middle molecules.
Participants assigned to high-flux treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, high-flux treatment will be delivered using the ELISIO™ HF series (Nipro).
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Serum Interleukin-6 (IL-6)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Comparison of serum interleukin-6 (IL-6) concentrations during treatment with medium cut-off and high-flux hemodialysis membranes.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Serum Vascular Cell Adhesion Molecule-1 (VCAM-1)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Comparison of serum vascular cell adhesion molecule-1 (VCAM-1) concentrations during treatment with medium cut-off and high-flux hemodialysis membranes.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Change in Pulse Wave Velocity (PWV)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of arterial stiffness by pulse wave velocity measurements.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Handgrip Strength
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of physical function using handgrip strength measurement.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Kidney Disease Quality of Life-36 (KDQOL-36) Score
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of patient-reported quality of life using the KDQOL-36 questionnaire.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in UP-Dial Pruritus Score
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of pruritus severity using the Uraemic Pruritus in Dialysis Patients (UP-Dial) scale.
The UP-Dial total score ranges from 0 to 56, with higher scores indicating more severe pruritus and a worse outcome.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Short-Form McGill Pain Questionnaire (SF-MPQ) Score
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of pain using the Short-Form McGill Pain Questionnaire (SF-MPQ) total Pain Rating Index score.
The SF-MPQ total Pain Rating Index score is calculated from 15 pain descriptors, each scored from 0 to 3, resulting in a total score range of 0 to 45. Higher scores indicate greater pain severity and a worse outcome.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Overhydration (OH)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of overhydration (OH, L) measured using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Extracellular Water to Total Body Water Ratio (ECW/TBW)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of the extracellular water to total body water ratio (ECW/TBW) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Intracellular Water (ICW)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of intracellular water (ICW, L) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Lean Tissue Index (LTI)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of lean tissue index (LTI, kg/m²) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Body Cell Mass (BCM)
時間枠:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of body cell mass (BCM, kg) using the Body Composition Monitor.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
協力者と研究者
スポンサー
出版物と役立つリンク
一般刊行物
- Zickler D, Schindler R, Willy K, Martus P, Pawlak M, Storr M, Hulko M, Boehler T, Glomb MA, Liehr K, Henning C, Templin M, Trojanowicz B, Ulrich C, Werner K, Fiedler R, Girndt M. Medium Cut-Off (MCO) Membranes Reduce Inflammation in Chronic Dialysis Patients-A Randomized Controlled Clinical Trial. PLoS One. 2017 Jan 13;12(1):e0169024. doi: 10.1371/journal.pone.0169024. eCollection 2017.
- Yang J, Ke G, Liao Y, Guo Y, Gao X. Efficacy of medium cut-off dialyzers and comparison with high-flux dialyzers in patients on maintenance hemodialysis: A systematic review and meta-analysis. Ther Apher Dial. 2022 Aug;26(4):756-768. doi: 10.1111/1744-9987.13755. Epub 2021 Dec 4.
- Kirsch AH, Lyko R, Nilsson LG, Beck W, Amdahl M, Lechner P, Schneider A, Wanner C, Rosenkranz AR, Krieter DH. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017 Jan 1;32(1):165-172. doi: 10.1093/ndt/gfw310.
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- GAZI-HD-MCO-HF-2026
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。