Randomized Cross-Over Comparison of Medium Cut-Off and High-Flux Hemodialysis Membranes (MCO-HD)
Randomized Cross-Over Evaluation of Medium Cut-Off and High-Flux Hemodialysis Membranes on Inflammation and Cardiovascular Function in Maintenance Hemodialysis Patients
Patients receiving maintenance hemodialysis are at increased risk of cardiovascular disease, chronic inflammation, endothelial dysfunction, and impaired quality of life. Medium cut-Off (MCO) hemodialysis membranes have been developed to enhance the removal of middle-molecular-weight uremic toxins compared with conventional high-flux membranes, which may improve inflammatory status and cardiovascular health.
The aim of this study is to compare the effects of MCO and high-flux hemodialysis membranes on inflammatory biomarkers and cardiovascular function in adult patients receiving maintenance hemodialysis. The primary outcomes are changes in serum interleukin-6 (IL-6) and vascular cell adhesion molecule-1 (VCAM-1) levels. Secondary outcomes include arterial stiffness assessed by pulse wave velocity (PWV), body composition assessed by Body Composition Monitor (BCM), handgrip strength, and patient-reported outcomes including quality of life, pruritus, and pain scores.
This is a prospective, randomized, open-label, two-sequence, two-period crossover study conducted at Gazi University Faculty of Medicine. Thirty adult hemodialysis patients will be randomized to one of two treatment sequences. Participants in Sequence A will receive MCO dialysis membranes for the first 3 months followed by high-flux membranes for the next 3 months. Participants in Sequence B will receive high-flux membranes for the first 3 months followed by MCO membranes for the next 3 months. Blood samples and clinical assessments will be performed at baseline, month 3, and month 6.
The study is expected to provide evidence regarding the effects of different dialysis membrane technologies on inflammation and cardiovascular health and may contribute to optimizing membrane selection in routine hemodialysis practice.
研究概览
地位
详细说明
Cardiovascular disease remains the leading cause of morbidity and mortality in patients receiving maintenance hemodialysis. Chronic inflammation, endothelial dysfunction, vascular stiffness, and the accumulation of middle-molecular-weight uremic toxins are considered important contributors to adverse cardiovascular outcomes in this population. Conventional high-flux hemodialysis membranes provide effective small-solute clearance but have limited capacity for removing larger middle molecules involved in inflammation and vascular injury.
Medium cut-off (MCO) membranes have been developed to enhance the clearance of larger middle molecules while maintaining albumin retention within acceptable limits. Previous studies have suggested that MCO membranes may improve inflammatory profiles and patient-centered outcomes; however, data regarding their effects on endothelial dysfunction, arterial stiffness, body composition, and patient-reported outcomes remain limited.
This study is designed as a prospective, randomized, open-label, two-sequence, two-period crossover clinical investigation comparing MCO and high-flux hemodialysis membranes in maintenance hemodialysis patients. Participants will be randomized in a 1:1 ratio to one of two treatment sequences. Sequence A will receive MCO membranes during Period 1 (Months 0-3) followed by high-flux membranes during Period 2 (Months 3-6). Sequence B will receive high-flux membranes during Period 1 followed by MCO membranes during Period 2. This crossover design allows each participant to serve as his or her own control, thereby reducing inter-individual variability.
Study assessments will be performed at baseline, Month 3, and Month 6. In addition to routine laboratory testing performed during standard hemodialysis follow-up, blood samples will be obtained at baseline, Month 3, and Month 6 for the measurement of serum interleukin-6 (IL-6) and vascular cell adhesion molecule-1 (VCAM-1). Cardiovascular assessment will include pulse wave velocity (PWV) measurement. Nutritional and body composition status will be evaluated using Body Composition Monitor (BCM) parameters, including overhydration, ECW/TBW ratio, intracellular water, lean tissue index, body cell mass, and phase angle. Functional status will be assessed by handgrip strength measurement. Patient-reported outcomes will be evaluated using the Kidney Disease Quality of Life-36 (KDQOL-36), UP-Dial pruritus questionnaire, and Short-Form McGill Pain Questionnaire (SF-MPQ).
The primary objective is to compare the effects of MCO and high-flux membranes on IL-6 and VCAM-1 levels. Secondary objectives include evaluation of arterial stiffness, body composition, physical function, and patient-reported outcomes. The findings may provide clinically relevant evidence regarding membrane selection strategies in routine hemodialysis practice.
研究类型
注册 (估计的)
阶段
- 不适用
联系人和位置
学习地点
-
-
Ankara
-
Ankara、Ankara、土耳其(türkiye)、06500
- Gazi University Faculty of Medicine, Department of Nephrology, Hemodialysis Unit
-
-
参与标准
资格标准
适合学习的年龄
- 成人
- 年长者
接受健康志愿者
描述
Inclusion Criteria:
- Age 18 to 80 years.
- Receiving maintenance hemodialysis for at least 6 months.
- Clinically stable and receiving thrice-weekly hemodialysis.
- Able to comply with study procedures, questionnaires, and scheduled assessments.
- Able and willing to provide written informed consent.
Exclusion Criteria:
- Acute infection at screening or enrollment.
- Major surgery within the previous 3 months.
- Active malignancy requiring ongoing treatment.
- Terminal illness with limited life expectancy.
- Physical or cognitive impairment preventing completion of study procedures or questionnaires.
- Inability or unwillingness to provide written informed consent.
学习计划
研究是如何设计的?
设计细节
- 主要用途:治疗
- 分配:随机化
- 介入模型:交叉作业
- 屏蔽:无(打开标签)
武器和干预
参与者组/臂 |
干预/治疗 |
|---|---|
|
实验性的:Sequence A (MCO to High-Flux)
Participants randomized to Sequence A will receive medium cut-off (MCO) hemodialysis membranes during Period 1 (Months 0-3), followed by high-flux hemodialysis membranes during Period 2 (Months 3-6).
Hemodialysis will be performed three times weekly according to standard clinical practice.
Clinical, laboratory, and patient-reported outcome assessments will be performed at baseline, Month 3, and Month 6.
|
Medium cut-off (MCO) hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
MCO membranes are designed to enhance the clearance of larger middle-molecular-weight uremic toxins while maintaining clinically acceptable albumin retention.
Participants assigned to MCO treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, MCO treatment will be delivered using the ELISIO™ MCO series (Nipro).
High-flux hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
High-flux membranes represent the current standard dialysis technology and provide effective clearance of small solutes and selected middle molecules.
Participants assigned to high-flux treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, high-flux treatment will be delivered using the ELISIO™ HF series (Nipro).
|
|
实验性的:Sequence B (High-Flux to MCO)
Participants randomized to Sequence B will receive high-flux hemodialysis membranes during Period 1 (Months 0-3), followed by medium cut-off (MCO) hemodialysis membranes during Period 2 (Months 3-6).
Hemodialysis will be performed three times weekly according to standard clinical practice.
Clinical, laboratory, and patient-reported outcome assessments will be performed at baseline, Month 3, and Month 6.
|
Medium cut-off (MCO) hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
MCO membranes are designed to enhance the clearance of larger middle-molecular-weight uremic toxins while maintaining clinically acceptable albumin retention.
Participants assigned to MCO treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, MCO treatment will be delivered using the ELISIO™ MCO series (Nipro).
High-flux hemodialysis membrane used as part of routine maintenance hemodialysis treatment.
High-flux membranes represent the current standard dialysis technology and provide effective clearance of small solutes and selected middle molecules.
Participants assigned to high-flux treatment periods will receive thrice-weekly hemodialysis according to standard clinical practice.
In this study, high-flux treatment will be delivered using the ELISIO™ HF series (Nipro).
|
研究衡量的是什么?
主要结果指标
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change in Serum Interleukin-6 (IL-6)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Comparison of serum interleukin-6 (IL-6) concentrations during treatment with medium cut-off and high-flux hemodialysis membranes.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Serum Vascular Cell Adhesion Molecule-1 (VCAM-1)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Comparison of serum vascular cell adhesion molecule-1 (VCAM-1) concentrations during treatment with medium cut-off and high-flux hemodialysis membranes.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
次要结果测量
结果测量 |
措施说明 |
大体时间 |
|---|---|---|
|
Change in Pulse Wave Velocity (PWV)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of arterial stiffness by pulse wave velocity measurements.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Handgrip Strength
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of physical function using handgrip strength measurement.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Kidney Disease Quality of Life-36 (KDQOL-36) Score
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of patient-reported quality of life using the KDQOL-36 questionnaire.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in UP-Dial Pruritus Score
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of pruritus severity using the Uraemic Pruritus in Dialysis Patients (UP-Dial) scale.
The UP-Dial total score ranges from 0 to 56, with higher scores indicating more severe pruritus and a worse outcome.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Short-Form McGill Pain Questionnaire (SF-MPQ) Score
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Evaluation of pain using the Short-Form McGill Pain Questionnaire (SF-MPQ) total Pain Rating Index score.
The SF-MPQ total Pain Rating Index score is calculated from 15 pain descriptors, each scored from 0 to 3, resulting in a total score range of 0 to 45. Higher scores indicate greater pain severity and a worse outcome.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Overhydration (OH)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of overhydration (OH, L) measured using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Extracellular Water to Total Body Water Ratio (ECW/TBW)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of the extracellular water to total body water ratio (ECW/TBW) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Intracellular Water (ICW)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of intracellular water (ICW, L) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Lean Tissue Index (LTI)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of lean tissue index (LTI, kg/m²) using the Body Composition Monitor (BCM).
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
|
Change in Body Cell Mass (BCM)
大体时间:At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
Assessment of body cell mass (BCM, kg) using the Body Composition Monitor.
|
At baseline (July 2026), Month 3 (October 2026), and Month 6 (January 2027)
|
合作者和调查者
出版物和有用的链接
一般刊物
- Zickler D, Schindler R, Willy K, Martus P, Pawlak M, Storr M, Hulko M, Boehler T, Glomb MA, Liehr K, Henning C, Templin M, Trojanowicz B, Ulrich C, Werner K, Fiedler R, Girndt M. Medium Cut-Off (MCO) Membranes Reduce Inflammation in Chronic Dialysis Patients-A Randomized Controlled Clinical Trial. PLoS One. 2017 Jan 13;12(1):e0169024. doi: 10.1371/journal.pone.0169024. eCollection 2017.
- Yang J, Ke G, Liao Y, Guo Y, Gao X. Efficacy of medium cut-off dialyzers and comparison with high-flux dialyzers in patients on maintenance hemodialysis: A systematic review and meta-analysis. Ther Apher Dial. 2022 Aug;26(4):756-768. doi: 10.1111/1744-9987.13755. Epub 2021 Dec 4.
- Kirsch AH, Lyko R, Nilsson LG, Beck W, Amdahl M, Lechner P, Schneider A, Wanner C, Rosenkranz AR, Krieter DH. Performance of hemodialysis with novel medium cut-off dialyzers. Nephrol Dial Transplant. 2017 Jan 1;32(1):165-172. doi: 10.1093/ndt/gfw310.
研究记录日期
研究主要日期
学习开始 (实际的)
初级完成 (估计的)
研究完成 (估计的)
研究注册日期
首次提交
首先提交符合 QC 标准的
首次发布 (实际的)
研究记录更新
最后更新发布 (实际的)
上次提交的符合 QC 标准的更新
最后验证
更多信息
与本研究相关的术语
其他相关的 MeSH 术语
其他研究编号
- GAZI-HD-MCO-HF-2026
计划个人参与者数据 (IPD)
计划共享个人参与者数据 (IPD)?
IPD 计划说明
药物和器械信息、研究文件
研究美国 FDA 监管的药品
研究美国 FDA 监管的设备产品
此信息直接从 clinicaltrials.gov 网站检索,没有任何更改。如果您有任何更改、删除或更新研究详细信息的请求,请联系 register@clinicaltrials.gov. clinicaltrials.gov 上实施更改,我们的网站上也会自动更新.