Bispectral Index and First-Pass Intubation
Evaluation of First-Pass Endotracheal Intubation Success Using the Bispectral Index in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study aims to evaluate the association between anesthetic depth, measured by the Bispectral Index (BIS), and first-pass endotracheal intubation success in adult patients undergoing rapid sequence intubation (RSI) in the emergency department.
Endotracheal intubation is one of the most critical procedures performed in emergency medicine. Multiple intubation attempts are associated with an increased risk of adverse events, including hypoxemia, aspiration, cardiovascular complications, and death. Although several factors influence first-pass intubation success, the contribution of anesthetic depth at the time of intubation has not been adequately investigated in the emergency department.
Patients for whom the treating emergency physician decides to perform RSI will undergo noninvasive BIS monitoring using a disposable forehead sensor. The physician performing the intubation will remain blinded to the BIS value throughout the procedure and will perform intubation according to routine clinical practice. A separate investigator, who is not involved in patient management, will record the BIS value at the time of intubation.
The BIS measurements will not be disclosed to the treating team and will not influence clinical decision-making, medication dosing, or patient management. The study is purely observational and does not evaluate the performance or effectiveness of the BIS device itself.
The primary objective is to determine whether patients who achieve first-pass intubation success differ in anesthetic depth from those requiring multiple intubation attempts.
調査の概要
状態
条件
詳細な説明
Endotracheal intubation is a life-saving intervention frequently performed in the emergency department for patients with airway compromise, respiratory failure, or critical illness. Despite its importance, emergency airway management is associated with a substantial risk of adverse events. Previous studies have consistently demonstrated that multiple intubation attempts significantly increase the likelihood of hypoxemia, aspiration, hypotension, cardiac arrest, airway trauma, and mortality. Therefore, achieving first-pass success has become one of the principal quality indicators in emergency airway management.
Several patient-, operator-, and procedure-related factors influence first-pass success, including anatomical difficulty, operator experience, type of laryngoscope, choice of sedative and neuromuscular blocking agents, and optimization of preoxygenation. Another potentially important but understudied factor is the depth of anesthesia at the moment of laryngoscopy and intubation.
Adequate anesthetic depth before laryngoscopy suppresses airway reflexes, minimizes patient movement, and improves intubating conditions. Previous studies comparing succinylcholine and rocuronium have suggested differences in intubation conditions; however, subsequent investigations demonstrated that these differences were largely attributable to dosing strategies rather than the neuromuscular blocking agent itself. Current evidence indicates that when appropriate doses are administered, both agents provide comparable intubating conditions. Nevertheless, regardless of the neuromuscular blocking agent used, insufficient hypnotic depth may adversely affect intubation conditions.
The Bispectral Index (BIS) is a processed electroencephalographic parameter ranging from 0 to 100 that provides an objective assessment of the patient's level of consciousness. BIS monitoring has been extensively validated in the operating room and has demonstrated a strong correlation with anesthetic depth. Randomized clinical trials have shown that BIS-guided anesthesia reduces the incidence of intraoperative awareness and may facilitate individualized anesthetic administration. However, BIS monitoring is not routinely incorporated into emergency airway management, and limited evidence exists regarding its relationship with first-pass intubation success in emergency department patients.
This study is designed as a prospective observational study. Adult patients undergoing rapid sequence intubation after a clinical decision by the treating emergency physician will be consecutively enrolled. A disposable BIS sensor will be placed on the patient's forehead immediately before induction, and BIS monitoring will be performed continuously. The emergency physician performing the intubation will remain blinded to the BIS values throughout the procedure. A separate investigator, independent of clinical management, will record the BIS value at the time of laryngoscopy and intubation.
Importantly, BIS measurements will not be communicated to the treating physician and will not influence the timing of intubation, medication selection, medication dosing, or any other aspect of patient care. Therefore, this investigation is not intended to evaluate or validate the BIS device as a medical device intervention. Rather, BIS is used solely as a noninvasive measurement tool to objectively quantify anesthetic depth. The monitor consists of a disposable adhesive forehead sensor and poses minimal risk to participants.
The primary analysis will compare BIS values between patients with successful first-pass intubation and those requiring more than one intubation attempt. The study seeks to determine whether inadequate anesthetic depth is associated with failure of first-pass intubation. The findings may improve understanding of the role of anesthetic depth during emergency airway management and may contribute to strategies aimed at increasing first-pass success while reducing intubation-related complications.
研究の種類
入学 (推定)
連絡先と場所
研究連絡先
- 名前:Muhammed Türe, MD
- 電話番号:+905054691764
- メール:erkangoksu@akdeniz.edu.tr
研究連絡先のバックアップ
- 名前:Erkan Göksu, MD
- 電話番号:00905054691764
- メール:erkangoksu@akdeniz.edu.tr
研究場所
-
-
-
Antalya、トルコ(Türkiye)、07059
- 募集
- Akdeniz University Hospital
-
コンタクト:
- Erkan Göksu, MD
- 電話番号:05054691764
- メール:erkangoksu@akdeniz.edu.tr
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Adults aged 18 years or older
- Patients undergoing rapid sequence intubation (RSI) in the emergency department
- No traumatic injury to the frontal region that would interfere with placement of the Bispectral Index (BIS) sensor
Exclusion Criteria:
- Age younger than 18 years
- Pregnant patients
- Patients with cardiac arrest or hemodynamic instability at the time of enrollment
- Patients intubated without the rapid sequence intubation (RSI) protocol
- Refusal to participate in the study (by the patient or, where applicable, a legally authorized representative)
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
|---|
|
Adults Undergoing Rapid Sequence Intubation
Adult patients (≥18 years) undergoing rapid sequence intubation (RSI) in the emergency department following the treating physician's clinical decision.
A noninvasive Bispectral Index (BIS) sensor is placed on the patient's forehead before induction to continuously monitor anesthetic depth.
The treating physician remains blinded to the BIS values, which are recorded by an independent investigator and are not used to guide patient management or influence the intubation procedure.
Participants are analyzed according to first-pass intubation success.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
First-pass endotracheal intubation success
時間枠:During the intubation procedure
|
Intubation at first attempt
|
During the intubation procedure
|
協力者と研究者
捜査官
- スタディディレクター:Erkan Göksu、Akdeniz University School of Medicine Department of Emergency Medicine
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- AUH (Aarhus University Hospital)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
IPD 共有時間枠
IPD 共有アクセス基準
IPD 共有サポート情報タイプ
- SAP
- ANALYTIC_CODE
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。