Bispectral Index and First-Pass Intubation
Evaluation of First-Pass Endotracheal Intubation Success Using the Bispectral Index in Patients Undergoing Endotracheal Intubation in the Emergency Department
This prospective observational study aims to evaluate the association between anesthetic depth, measured by the Bispectral Index (BIS), and first-pass endotracheal intubation success in adult patients undergoing rapid sequence intubation (RSI) in the emergency department.
Endotracheal intubation is one of the most critical procedures performed in emergency medicine. Multiple intubation attempts are associated with an increased risk of adverse events, including hypoxemia, aspiration, cardiovascular complications, and death. Although several factors influence first-pass intubation success, the contribution of anesthetic depth at the time of intubation has not been adequately investigated in the emergency department.
Patients for whom the treating emergency physician decides to perform RSI will undergo noninvasive BIS monitoring using a disposable forehead sensor. The physician performing the intubation will remain blinded to the BIS value throughout the procedure and will perform intubation according to routine clinical practice. A separate investigator, who is not involved in patient management, will record the BIS value at the time of intubation.
The BIS measurements will not be disclosed to the treating team and will not influence clinical decision-making, medication dosing, or patient management. The study is purely observational and does not evaluate the performance or effectiveness of the BIS device itself.
The primary objective is to determine whether patients who achieve first-pass intubation success differ in anesthetic depth from those requiring multiple intubation attempts.
Descripción general del estudio
Estado
Condiciones
Descripción detallada
Endotracheal intubation is a life-saving intervention frequently performed in the emergency department for patients with airway compromise, respiratory failure, or critical illness. Despite its importance, emergency airway management is associated with a substantial risk of adverse events. Previous studies have consistently demonstrated that multiple intubation attempts significantly increase the likelihood of hypoxemia, aspiration, hypotension, cardiac arrest, airway trauma, and mortality. Therefore, achieving first-pass success has become one of the principal quality indicators in emergency airway management.
Several patient-, operator-, and procedure-related factors influence first-pass success, including anatomical difficulty, operator experience, type of laryngoscope, choice of sedative and neuromuscular blocking agents, and optimization of preoxygenation. Another potentially important but understudied factor is the depth of anesthesia at the moment of laryngoscopy and intubation.
Adequate anesthetic depth before laryngoscopy suppresses airway reflexes, minimizes patient movement, and improves intubating conditions. Previous studies comparing succinylcholine and rocuronium have suggested differences in intubation conditions; however, subsequent investigations demonstrated that these differences were largely attributable to dosing strategies rather than the neuromuscular blocking agent itself. Current evidence indicates that when appropriate doses are administered, both agents provide comparable intubating conditions. Nevertheless, regardless of the neuromuscular blocking agent used, insufficient hypnotic depth may adversely affect intubation conditions.
The Bispectral Index (BIS) is a processed electroencephalographic parameter ranging from 0 to 100 that provides an objective assessment of the patient's level of consciousness. BIS monitoring has been extensively validated in the operating room and has demonstrated a strong correlation with anesthetic depth. Randomized clinical trials have shown that BIS-guided anesthesia reduces the incidence of intraoperative awareness and may facilitate individualized anesthetic administration. However, BIS monitoring is not routinely incorporated into emergency airway management, and limited evidence exists regarding its relationship with first-pass intubation success in emergency department patients.
This study is designed as a prospective observational study. Adult patients undergoing rapid sequence intubation after a clinical decision by the treating emergency physician will be consecutively enrolled. A disposable BIS sensor will be placed on the patient's forehead immediately before induction, and BIS monitoring will be performed continuously. The emergency physician performing the intubation will remain blinded to the BIS values throughout the procedure. A separate investigator, independent of clinical management, will record the BIS value at the time of laryngoscopy and intubation.
Importantly, BIS measurements will not be communicated to the treating physician and will not influence the timing of intubation, medication selection, medication dosing, or any other aspect of patient care. Therefore, this investigation is not intended to evaluate or validate the BIS device as a medical device intervention. Rather, BIS is used solely as a noninvasive measurement tool to objectively quantify anesthetic depth. The monitor consists of a disposable adhesive forehead sensor and poses minimal risk to participants.
The primary analysis will compare BIS values between patients with successful first-pass intubation and those requiring more than one intubation attempt. The study seeks to determine whether inadequate anesthetic depth is associated with failure of first-pass intubation. The findings may improve understanding of the role of anesthetic depth during emergency airway management and may contribute to strategies aimed at increasing first-pass success while reducing intubation-related complications.
Tipo de estudio
Inscripción (Estimado)
Contactos y Ubicaciones
Estudio Contacto
- Nombre: Muhammed Türe, MD
- Número de teléfono: +905054691764
- Correo electrónico: erkangoksu@akdeniz.edu.tr
Copia de seguridad de contactos de estudio
- Nombre: Erkan Göksu, MD
- Número de teléfono: 00905054691764
- Correo electrónico: erkangoksu@akdeniz.edu.tr
Ubicaciones de estudio
-
-
-
Antalya, Turquía (Türkiye), 07059
- Reclutamiento
- Akdeniz University Hospital
-
Contacto:
- Erkan Göksu, MD
- Número de teléfono: 05054691764
- Correo electrónico: erkangoksu@akdeniz.edu.tr
-
-
Criterios de participación
Criterio de elegibilidad
Edades elegibles para estudiar
- Adulto
- Adulto Mayor
Acepta Voluntarios Saludables
Método de muestreo
Población de estudio
Descripción
Inclusion Criteria:
- Adults aged 18 years or older
- Patients undergoing rapid sequence intubation (RSI) in the emergency department
- No traumatic injury to the frontal region that would interfere with placement of the Bispectral Index (BIS) sensor
Exclusion Criteria:
- Age younger than 18 years
- Pregnant patients
- Patients with cardiac arrest or hemodynamic instability at the time of enrollment
- Patients intubated without the rapid sequence intubation (RSI) protocol
- Refusal to participate in the study (by the patient or, where applicable, a legally authorized representative)
Plan de estudios
¿Cómo está diseñado el estudio?
Detalles de diseño
Cohortes e Intervenciones
Grupo / Cohorte |
|---|
|
Adults Undergoing Rapid Sequence Intubation
Adult patients (≥18 years) undergoing rapid sequence intubation (RSI) in the emergency department following the treating physician's clinical decision.
A noninvasive Bispectral Index (BIS) sensor is placed on the patient's forehead before induction to continuously monitor anesthetic depth.
The treating physician remains blinded to the BIS values, which are recorded by an independent investigator and are not used to guide patient management or influence the intubation procedure.
Participants are analyzed according to first-pass intubation success.
|
¿Qué mide el estudio?
Medidas de resultado primarias
Medida de resultado |
Medida Descripción |
Periodo de tiempo |
|---|---|---|
|
First-pass endotracheal intubation success
Periodo de tiempo: During the intubation procedure
|
Intubation at first attempt
|
During the intubation procedure
|
Colaboradores e Investigadores
Patrocinador
Investigadores
- Director de estudio: Erkan Göksu, Akdeniz University School of Medicine Department of Emergency Medicine
Fechas de registro del estudio
Fechas importantes del estudio
Inicio del estudio (Actual)
Finalización primaria (Estimado)
Finalización del estudio (Estimado)
Fechas de registro del estudio
Enviado por primera vez
Primero enviado que cumplió con los criterios de control de calidad
Publicado por primera vez (Actual)
Actualizaciones de registros de estudio
Última actualización publicada (Actual)
Última actualización enviada que cumplió con los criterios de control de calidad
Última verificación
Más información
Términos relacionados con este estudio
Palabras clave
Otros números de identificación del estudio
- AUH (Aarhus University Hospital)
Plan de datos de participantes individuales (IPD)
¿Planea compartir datos de participantes individuales (IPD)?
Descripción del plan IPD
Marco de tiempo para compartir IPD
Criterios de acceso compartido de IPD
Tipo de información de apoyo para compartir IPD
- SAVIA
- CÓDIGO_ANALÍTICO
Información sobre medicamentos y dispositivos, documentos del estudio
Estudia un producto farmacéutico regulado por la FDA de EE. UU.
Estudia un producto de dispositivo regulado por la FDA de EE. UU.
producto fabricado y exportado desde los EE. UU.
Esta información se obtuvo directamente del sitio web clinicaltrials.gov sin cambios. Si tiene alguna solicitud para cambiar, eliminar o actualizar los detalles de su estudio, comuníquese con register@clinicaltrials.gov. Tan pronto como se implemente un cambio en clinicaltrials.gov, también se actualizará automáticamente en nuestro sitio web. .