Individualized Supramaximal Stimulation Current During Continuous Neuromonitoring in Thyroid Surgery (CIONM-SSC)
Patient-Specific Determination of Supramaximal Stimulation Current During Continuous Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
Continuous intraoperative neuromonitoring (C-IONM) is increasingly used during thyroid surgery to detect early changes in recurrent laryngeal nerve function and reduce the risk of nerve injury. Current clinical practice recommends the use of fixed supramaximal stimulation currents; however, these recommendations are based on limited experimental evidence and may not account for individual variability between patients.
This retrospective observational cohort study aims to determine patient-specific supramaximal stimulation currents (SSC) during C-IONM and to evaluate whether individualized stimulation provides monitoring quality comparable to conventional fixed-current stimulation while potentially reducing unnecessary stimulation intensity. The study also investigates factors influencing electromyographic response amplitudes during surgery and assesses the safety of individualized stimulation parameters.
調査の概要
状態
条件
詳細な説明
Continuous intraoperative neuromonitoring (C-IONM) of the vagus nerve is increasingly used during thyroid surgery to facilitate early recognition of progressive recurrent laryngeal nerve (RLN) injury. Current international recommendations advocate the use of a fixed supramaximal stimulation current, typically between 1 and 2 mA. However, these recommendations are based on limited experimental and clinical evidence and do not account for potential interindividual differences in nerve excitability.
The aim of this retrospective observational cohort study was to characterize the distribution of patient-specific supramaximal stimulation current (SSC) during C-IONM and to determine whether individualized SSC selection maintains monitoring performance compared with conventional fixed-current stimulation. Secondary objectives included evaluation of factors affecting electromyographic response amplitude and assessment of the safety of individualized stimulation.
The study included consecutive adult patients undergoing thyroid surgery with C-IONM at a tertiary endocrine surgery center. Patients operated before implementation of an updated stimulation protocol constituted the control cohort and underwent monitoring using a fixed stimulation current of 1.5 mA. After protocol implementation, SSC was individually determined for each vagus nerve at the beginning of the procedure by gradually increasing stimulation current until no further increase in electromyographic response amplitude was observed. Continuous monitoring was subsequently performed using the individualized SSC.
Neuromonitoring recordings were exported from the monitoring system, anonymized, and analyzed using dedicated Python software developed for this study. The software identified individual stimulation events, excluded incomplete or technically inadequate recordings, and extracted stimulation current and electromyographic amplitude for quantitative analysis. More than one million individual stimulation responses were evaluated.
The primary objective was to determine the distribution of individualized SSC values and compare monitoring performance between individualized and fixed-current stimulation. Secondary analyses evaluated changes in response amplitude during surgery, variability between right and left vagus nerves, factors influencing amplitude, and the occurrence of monitoring-related adverse events.
Statistical analyses included descriptive statistics, non-parametric comparisons, regression analysis, and multivariable modeling to identify independent predictors of electromyographic response amplitude.
研究の種類
入学 (実際)
連絡先と場所
研究場所
-
-
-
Gdansk、ポーランド、80-135
- The University Clinical Centre in Gdansk
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
サンプリング方法
調査対象母集団
説明
Inclusion Criteria:
- Adults aged 18 years or older.
- Patients undergoing thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) of the vagus nerve.
- Availability of complete intraoperative neuromonitoring recordings suitable for analysis.
- Availability of complete clinical and operative data.
Exclusion Criteria:
- Age younger than 18 years.
- Incomplete or technically inadequate neuromonitoring recordings.
- Loss of signal or recurrent laryngeal nerve palsy preventing reliable amplitude analysis.
- Missing or incomplete clinical data required for the study.
研究計画
研究はどのように設計されていますか?
デザインの詳細
コホートと介入
グループ/コホート |
介入・治療 |
|---|---|
|
Control cohort
Patients who underwent thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) using a fixed vagus nerve stimulation current of 1.5 mA throughout the procedure.
These patients were operated before implementation of the individualized stimulation protocol.
|
Continuous vagus nerve stimulation during thyroid surgery using a fixed supramaximal stimulation current of 1.5 mA.
|
|
Individualized SSC cohort
Patients who underwent thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) using an individually determined supramaximal stimulation current (SSC).
SSC was established at the beginning of the procedure for each vagus nerve and subsequently used throughout continuous monitoring.
|
Continuous vagus nerve stimulation during thyroid surgery using an individually determined supramaximal stimulation current established at the beginning of the procedure.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Patient-specific supramaximal stimulation current
時間枠:During surgery
|
Distribution of the individualized supramaximal stimulation current required to achieve maximal electromyographic response during continuous intraoperative neuromonitoring of the vagus nerve.
|
During surgery
|
|
Patient-specific supramaximal stimulation current (SSC)
時間枠:During surgery (at the beginning of continuous intraoperative neuromonitoring)
|
Distribution of the individualized supramaximal stimulation current (SSC) required to achieve maximal electromyographic response during continuous intraoperative neuromonitoring of the vagus nerve.
|
During surgery (at the beginning of continuous intraoperative neuromonitoring)
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Electromyographic response amplitude
時間枠:During surgery
|
Comparison of electromyographic response amplitudes between individualized and fixed stimulation current protocols during continuous intraoperative neuromonitoring.
|
During surgery
|
協力者と研究者
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- KB/202/2025
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。