Individualized Supramaximal Stimulation Current During Continuous Neuromonitoring in Thyroid Surgery (CIONM-SSC)
Patient-Specific Determination of Supramaximal Stimulation Current During Continuous Intraoperative Neuromonitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
Continuous intraoperative neuromonitoring (C-IONM) is increasingly used during thyroid surgery to detect early changes in recurrent laryngeal nerve function and reduce the risk of nerve injury. Current clinical practice recommends the use of fixed supramaximal stimulation currents; however, these recommendations are based on limited experimental evidence and may not account for individual variability between patients.
This retrospective observational cohort study aims to determine patient-specific supramaximal stimulation currents (SSC) during C-IONM and to evaluate whether individualized stimulation provides monitoring quality comparable to conventional fixed-current stimulation while potentially reducing unnecessary stimulation intensity. The study also investigates factors influencing electromyographic response amplitudes during surgery and assesses the safety of individualized stimulation parameters.
Tutkimuksen yleiskatsaus
Tila
Yksityiskohtainen kuvaus
Continuous intraoperative neuromonitoring (C-IONM) of the vagus nerve is increasingly used during thyroid surgery to facilitate early recognition of progressive recurrent laryngeal nerve (RLN) injury. Current international recommendations advocate the use of a fixed supramaximal stimulation current, typically between 1 and 2 mA. However, these recommendations are based on limited experimental and clinical evidence and do not account for potential interindividual differences in nerve excitability.
The aim of this retrospective observational cohort study was to characterize the distribution of patient-specific supramaximal stimulation current (SSC) during C-IONM and to determine whether individualized SSC selection maintains monitoring performance compared with conventional fixed-current stimulation. Secondary objectives included evaluation of factors affecting electromyographic response amplitude and assessment of the safety of individualized stimulation.
The study included consecutive adult patients undergoing thyroid surgery with C-IONM at a tertiary endocrine surgery center. Patients operated before implementation of an updated stimulation protocol constituted the control cohort and underwent monitoring using a fixed stimulation current of 1.5 mA. After protocol implementation, SSC was individually determined for each vagus nerve at the beginning of the procedure by gradually increasing stimulation current until no further increase in electromyographic response amplitude was observed. Continuous monitoring was subsequently performed using the individualized SSC.
Neuromonitoring recordings were exported from the monitoring system, anonymized, and analyzed using dedicated Python software developed for this study. The software identified individual stimulation events, excluded incomplete or technically inadequate recordings, and extracted stimulation current and electromyographic amplitude for quantitative analysis. More than one million individual stimulation responses were evaluated.
The primary objective was to determine the distribution of individualized SSC values and compare monitoring performance between individualized and fixed-current stimulation. Secondary analyses evaluated changes in response amplitude during surgery, variability between right and left vagus nerves, factors influencing amplitude, and the occurrence of monitoring-related adverse events.
Statistical analyses included descriptive statistics, non-parametric comparisons, regression analysis, and multivariable modeling to identify independent predictors of electromyographic response amplitude.
Opintotyyppi
Ilmoittautuminen (Todellinen)
Yhteystiedot ja paikat
Opiskelupaikat
-
-
-
Gdansk, Puola, 80-135
- The University Clinical Centre in Gdansk
-
-
Osallistumiskriteerit
Kelpoisuusvaatimukset
Opintokelpoiset iät
- Aikuinen
- Vanhempi Aikuinen
Hyväksyy terveitä vapaaehtoisia
Näytteenottomenetelmä
Tutkimusväestö
Kuvaus
Inclusion Criteria:
- Adults aged 18 years or older.
- Patients undergoing thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) of the vagus nerve.
- Availability of complete intraoperative neuromonitoring recordings suitable for analysis.
- Availability of complete clinical and operative data.
Exclusion Criteria:
- Age younger than 18 years.
- Incomplete or technically inadequate neuromonitoring recordings.
- Loss of signal or recurrent laryngeal nerve palsy preventing reliable amplitude analysis.
- Missing or incomplete clinical data required for the study.
Opintosuunnitelma
Miten tutkimus on suunniteltu?
Suunnittelun yksityiskohdat
Kohortit ja interventiot
Ryhmä/Kohortti |
Interventio / Hoito |
|---|---|
|
Control cohort
Patients who underwent thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) using a fixed vagus nerve stimulation current of 1.5 mA throughout the procedure.
These patients were operated before implementation of the individualized stimulation protocol.
|
Continuous vagus nerve stimulation during thyroid surgery using a fixed supramaximal stimulation current of 1.5 mA.
|
|
Individualized SSC cohort
Patients who underwent thyroid surgery with continuous intraoperative neuromonitoring (C-IONM) using an individually determined supramaximal stimulation current (SSC).
SSC was established at the beginning of the procedure for each vagus nerve and subsequently used throughout continuous monitoring.
|
Continuous vagus nerve stimulation during thyroid surgery using an individually determined supramaximal stimulation current established at the beginning of the procedure.
|
Mitä tutkimuksessa mitataan?
Ensisijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Patient-specific supramaximal stimulation current
Aikaikkuna: During surgery
|
Distribution of the individualized supramaximal stimulation current required to achieve maximal electromyographic response during continuous intraoperative neuromonitoring of the vagus nerve.
|
During surgery
|
|
Patient-specific supramaximal stimulation current (SSC)
Aikaikkuna: During surgery (at the beginning of continuous intraoperative neuromonitoring)
|
Distribution of the individualized supramaximal stimulation current (SSC) required to achieve maximal electromyographic response during continuous intraoperative neuromonitoring of the vagus nerve.
|
During surgery (at the beginning of continuous intraoperative neuromonitoring)
|
Toissijaiset tulostoimenpiteet
Tulosmittaus |
Toimenpiteen kuvaus |
Aikaikkuna |
|---|---|---|
|
Electromyographic response amplitude
Aikaikkuna: During surgery
|
Comparison of electromyographic response amplitudes between individualized and fixed stimulation current protocols during continuous intraoperative neuromonitoring.
|
During surgery
|
Yhteistyökumppanit ja tutkijat
Sponsori
Opintojen ennätyspäivät
Opi tärkeimmät päivämäärät
Opiskelun aloitus (Todellinen)
Ensisijainen valmistuminen (Todellinen)
Opintojen valmistuminen (Todellinen)
Opintoihin ilmoittautumispäivät
Ensimmäinen lähetetty
Ensimmäinen toimitettu, joka täytti QC-kriteerit
Ensimmäinen Lähetetty (Todellinen)
Tutkimustietojen päivitykset
Viimeisin päivitys julkaistu (Todellinen)
Viimeisin lähetetty päivitys, joka täytti QC-kriteerit
Viimeksi vahvistettu
Lisää tietoa
Tähän tutkimukseen liittyvät termit
Avainsanat
Muita asiaankuuluvia MeSH-ehtoja
Muut tutkimustunnusnumerot
- KB/202/2025
Yksittäisten osallistujien tietojen suunnitelma (IPD)
Aiotko jakaa yksittäisten osallistujien tietoja (IPD)?
IPD-suunnitelman kuvaus
Lääke- ja laitetiedot, tutkimusasiakirjat
Tutkii yhdysvaltalaista FDA sääntelemää lääkevalmistetta
Tutkii yhdysvaltalaista FDA sääntelemää laitetuotetta
Nämä tiedot haettiin suoraan verkkosivustolta clinicaltrials.gov ilman muutoksia. Jos sinulla on pyyntöjä muuttaa, poistaa tai päivittää tutkimustietojasi, ota yhteyttä register@clinicaltrials.gov. Heti kun muutos on otettu käyttöön osoitteessa clinicaltrials.gov, se päivitetään automaattisesti myös verkkosivustollemme .