Speech Perception, Spatial Perception and Satisfaction Outcomes of Fitting Based on Hearing In Noise Ability
調査の概要
詳細な説明
Hypotheses:
H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.
H1: Using ACT in the fitting is more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.
H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.
H1: Using ACT in the fitting is more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.
H0: Using ACT in the fitting does not increase speech understanding performance in noise in hearing aid users.
H1: Using ACT in the fitting increases speech understanding performance in noise in hearing aid users.
H0: Using ACT in the fitting has no effect on improving spatial perception performance in hearing aid users.
H1: Using ACT in the fitting has an effect on improving spatial perception performance in hearing aid users.
H0: Using ACT in fitting has no effect on increasing hearing aid satisfaction in hearing aid users.
H1: Using ACT in fitting has an effect on increasing hearing aid satisfaction in hearing aid users.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Kucukcekmece
-
Istanbul、Kucukcekmece、トルコ(Türkiye)、34295
- Istanbul Aydın University
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Medium (41-55 dB) / moderate to severe (56-70 dB), sensorineural hearing loss (Goodman, 1965)
- SDS score between 70-100%
- Being a bilateral hearing aid user
- Being a user of Oticon, Philips, Bernafon hearing aids
- Being between 18-50 years of age
- Signing an informed consent form
Exclusion Criteria:
- Conditions with variable hearing loss such as Meniere's disease, ongoing treatment with ototoxic drugs
- Complaining with tinnitus
- Low cognitive capacity: Scoring below 24 on the Standardized Mini Mental Test
- Not signing an informed consent form
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:ヘルスサービス研究
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Experimental Group
The ACT method will be applied to the study group in fitting, and the results will be recorded by applying the KUİK scale and APHAB survey after fitting.
They will be called for control in the 1st week and 1st month, and fitting and scale evaluations will be made and the results will be recorded.
Participants' discrimination in noise with ACT and Turkish Matrix Test, evaluation of spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be evaluated in the initial and 1st month time periods.
|
The ACT diagnostic test is a suprathreshold, non-language-specific test that measures an individual's hearing ability in real-world noisy environments to determine the level of assistance needed in noise.
The test uses the audiogram shape and levels to ensure the correct stimulus intensity is applied.
The ACT test then uses the patient's audiogram to present a suprathreshold stimulus (a siren-like sound) to objectively map their hearing ability in noisy environments.
In other words, the audiogram measures quantity, i.e. hearing ability, while the ACT measures the quality of hearing.
This makes the ACT a robust assessment that reflects an individual's real-world hearing abilities.
他の名前:
|
|
アクティブコンパレータ:Control Group
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting.
Fitting and scale assessments will be made at week 1 and month 1, and the results will be recorded.
Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception assessment with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1.
|
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting.
They will be called for a check-up at week 1 and month 1, and fitting and scale assessments will be made, and the results will be recorded.
Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1.
All findings will be compared and statistically analyzed.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Eco-HINT
時間枠:1 week and 1 month after hearing aid fitting
|
Speech-in-noise performance was assessed using the ecologically valid Hearing in Noise Test (eco-HINT).
Speech reception thresholds were measured under aided and unaided listening conditions.
Lower scores indicate better speech-in-noise performance.
|
1 week and 1 month after hearing aid fitting
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Speech, Spatial Perception and Hearing Quality Scale
時間枠:1 week and 1 month after hearing aid fitting
|
The individual who is applied the scale evaluates himself/herself and answers each question between 0 and 10 points.
All scores are added up and divided by 49 to obtain the "General KUİK score".
The scores under the heading of Speech Perception are added up and divided by 14 to obtain the KA score, the scores under the heading of Spatial Perception are added up and divided by 17 to obtain the UA score, and the scores under the heading of Hearing Quality are added up and divided by 18 to obtain the İK score.
|
1 week and 1 month after hearing aid fitting
|
|
APHAB survey
時間枠:1 week and 1 month after hearing aid fitting
|
APHAB is a survey that allows us to numerically measure the benefits and satisfaction of individuals with hearing loss from their hearing aids in daily hearing situations.
Survey questions are answered according to two different listening situations: "without my hearing aid" and "with my hearing aid".
|
1 week and 1 month after hearing aid fitting
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Audible Contrast Threshold (ACT)
時間枠:Time Frame: 1 week and 1 month after hearing aid fitting
|
The ACT is a suprathreshold, non-language-specific test that measures an individual's ability to hear in real-world noisy environments to determine the level of assistance needed in noise.
ACT values are determined by level of intensity.
A normal ACT value is between -4 and +4 dB nCL. 4 to 7 dB nCL indicates mild loss, 7 to 10 dB nCL indicates moderate loss, and 10 to 16 dB nCL indicates profound loss.
|
Time Frame: 1 week and 1 month after hearing aid fitting
|
協力者と研究者
捜査官
- スタディディレクター:Sule Cekic, associate professor、Ankara Yildirim Beyazıt University
- スタディディレクター:Umıt Can Cetinkaya, assistant professor、Istanbul Aydın University
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (実際)
研究の完了 (実際)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
追加の関連 MeSH 用語
その他の研究ID番号
- 61351342/020-385
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。