このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

Speech Perception, Spatial Perception and Satisfaction Outcomes of Fitting Based on Hearing In Noise Ability

2026年8月8日 更新者:Melek Başak ÖZKAN、Istanbul Aydın University
Hearing speech in the presence of background noise is a significant challenge for those with hearing loss. Being able to hear speech in noise has been rated as the most sought-after feature in hearing aids by hearing aid users. Our study aims to evaluate the effects of adaptation to hearing test in noise on speech perception, spatial perception and satisfaction in bilateral hearing aid users. The development process of speech understanding in noise in individuals with hearing loss over the age of 50 will be monitored with ACT and ecological-HINT tests. Spatial perception will be assessed with the Speech, Spatial Perception and Hearing Quality (SHRQ) Scale, which is a scale that evaluates the current hearing quality in adults. The hearing aid satisfaction process of the participants will be assessed with the APHAB survey.

調査の概要

詳細な説明

Hypotheses:

H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.

H1: Using ACT in the fitting is more effective than the traditional fitting method in improving speech understanding performance in noise in hearing aid users.

H0: Using ACT in the fitting is not more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.

H1: Using ACT in the fitting is more effective than the traditional fitting method in improving spatial perception performance in hearing aid users.

H0: Using ACT in the fitting does not increase speech understanding performance in noise in hearing aid users.

H1: Using ACT in the fitting increases speech understanding performance in noise in hearing aid users.

H0: Using ACT in the fitting has no effect on improving spatial perception performance in hearing aid users.

H1: Using ACT in the fitting has an effect on improving spatial perception performance in hearing aid users.

H0: Using ACT in fitting has no effect on increasing hearing aid satisfaction in hearing aid users.

H1: Using ACT in fitting has an effect on increasing hearing aid satisfaction in hearing aid users.

研究の種類

介入

入学 (実際)

42

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究場所

    • Kucukcekmece
      • Istanbul、Kucukcekmece、トルコ(Türkiye)、34295
        • Istanbul Aydın University

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

  • 大人
  • 高齢者

健康ボランティアの受け入れ

いいえ

説明

Inclusion Criteria:

  • Medium (41-55 dB) / moderate to severe (56-70 dB), sensorineural hearing loss (Goodman, 1965)
  • SDS score between 70-100%
  • Being a bilateral hearing aid user
  • Being a user of Oticon, Philips, Bernafon hearing aids
  • Being between 18-50 years of age
  • Signing an informed consent form

Exclusion Criteria:

  • Conditions with variable hearing loss such as Meniere's disease, ongoing treatment with ototoxic drugs
  • Complaining with tinnitus
  • Low cognitive capacity: Scoring below 24 on the Standardized Mini Mental Test
  • Not signing an informed consent form

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:ヘルスサービス研究
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
アクティブコンパレータ:Experimental Group
The ACT method will be applied to the study group in fitting, and the results will be recorded by applying the KUİK scale and APHAB survey after fitting. They will be called for control in the 1st week and 1st month, and fitting and scale evaluations will be made and the results will be recorded. Participants' discrimination in noise with ACT and Turkish Matrix Test, evaluation of spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be evaluated in the initial and 1st month time periods.
The ACT diagnostic test is a suprathreshold, non-language-specific test that measures an individual's hearing ability in real-world noisy environments to determine the level of assistance needed in noise. The test uses the audiogram shape and levels to ensure the correct stimulus intensity is applied. The ACT test then uses the patient's audiogram to present a suprathreshold stimulus (a siren-like sound) to objectively map their hearing ability in noisy environments. In other words, the audiogram measures quantity, i.e. hearing ability, while the ACT measures the quality of hearing. This makes the ACT a robust assessment that reflects an individual's real-world hearing abilities.
他の名前:
  • hearing in noise
アクティブコンパレータ:Control Group
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting. Fitting and scale assessments will be made at week 1 and month 1, and the results will be recorded. Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception assessment with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1.
The control group will be fitted with traditional fittings, and the results will be recorded using the KUİK scale and APHAB survey after fitting. They will be called for a check-up at week 1 and month 1, and fitting and scale assessments will be made, and the results will be recorded. Participants' ability to discriminate in noise with the ACT and Turkish Matrix Test, spatial perception with the KUİK scale, and hearing aid satisfaction with the APHAB survey will be assessed at the beginning and month 1. All findings will be compared and statistically analyzed.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Eco-HINT
時間枠:1 week and 1 month after hearing aid fitting
Speech-in-noise performance was assessed using the ecologically valid Hearing in Noise Test (eco-HINT). Speech reception thresholds were measured under aided and unaided listening conditions. Lower scores indicate better speech-in-noise performance.
1 week and 1 month after hearing aid fitting

二次結果の測定

結果測定
メジャーの説明
時間枠
Speech, Spatial Perception and Hearing Quality Scale
時間枠:1 week and 1 month after hearing aid fitting
The individual who is applied the scale evaluates himself/herself and answers each question between 0 and 10 points. All scores are added up and divided by 49 to obtain the "General KUİK score". The scores under the heading of Speech Perception are added up and divided by 14 to obtain the KA score, the scores under the heading of Spatial Perception are added up and divided by 17 to obtain the UA score, and the scores under the heading of Hearing Quality are added up and divided by 18 to obtain the İK score.
1 week and 1 month after hearing aid fitting
APHAB survey
時間枠:1 week and 1 month after hearing aid fitting
APHAB is a survey that allows us to numerically measure the benefits and satisfaction of individuals with hearing loss from their hearing aids in daily hearing situations. Survey questions are answered according to two different listening situations: "without my hearing aid" and "with my hearing aid".
1 week and 1 month after hearing aid fitting

その他の成果指標

結果測定
メジャーの説明
時間枠
Audible Contrast Threshold (ACT)
時間枠:Time Frame: 1 week and 1 month after hearing aid fitting
The ACT is a suprathreshold, non-language-specific test that measures an individual's ability to hear in real-world noisy environments to determine the level of assistance needed in noise. ACT values are determined by level of intensity. A normal ACT value is between -4 and +4 dB nCL. 4 to 7 dB nCL indicates mild loss, 7 to 10 dB nCL indicates moderate loss, and 10 to 16 dB nCL indicates profound loss.
Time Frame: 1 week and 1 month after hearing aid fitting

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

捜査官

  • スタディディレクター:Sule Cekic, associate professor、Ankara Yildirim Beyazıt University
  • スタディディレクター:Umıt Can Cetinkaya, assistant professor、Istanbul Aydın University

出版物と役立つリンク

研究に関する情報を入力する責任者は、自発的にこれらの出版物を提供します。これらは、研究に関連するあらゆるものに関するものである可能性があります。

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (実際)

2025年2月13日

一次修了 (実際)

2025年5月2日

研究の完了 (実際)

2025年6月1日

試験登録日

最初に提出

2025年3月31日

QC基準を満たした最初の提出物

2026年8月8日

最初の投稿 (実際)

2026年8月11日

学習記録の更新

投稿された最後の更新 (実際)

2026年8月11日

QC基準を満たした最後の更新が送信されました

2026年8月8日

最終確認日

2026年3月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

IPD プランの説明

To ensure the privacy and confidentiality of participants, individual participant data (IPD) will not be shared. Since the study involves hearing aid users, it is extremely important to protect the integrity of their personal data. Furthermore, the guidelines of the ethics committee and institutional policies require strict data protection to prevent possible misuse. Therefore, IPD will remain confidential and will not be made public.

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する