Evaluation of 4D Intracardiac Echocardiography (ICE) During Structural Heart and Electrophysiology Procedures (4D-ICE)
Assessment of Utility of Siemens Healthineers 4D ICE and Premium CV System Workflow in Evaluation of Cardiac Anatomy and Physiology During Electrophysiology and Structural Heart Procedures
The purpose of this study is to evaluate the imaging performance and procedural safety of a prototype 4D ICE catheter during real-time intracardiac imaging and to optimize device imaging parameters, compared with current standard imaging modalities.
TEE is the current standard of care and will serve as the primary imaging modality for clinical guidance during the EP and Structural Heart Disease (SHD) procedures. In this research protocol, TEE is not being investigated. ICE will be used as an adjunct imaging modality for research data collection and workflow evaluation only. All procedures will be performed using commercially available, FDA-approved Watchman devices, and no investigational implantable devices will be used. The use of ICE in this study does not modify the approved therapeutic device indication, implantation technique, or standard clinical decision-making.
調査の概要
詳細な説明
This study is a prospective clinical feasibility study designed to evaluate the imaging performance, workflow efficiency, and safety of a prototype 4D intracardiac echocardiography (ICE) catheter (ACUNAV Luxera) used in conjunction with the Siemens Premium CV ultrasound system during cardiac interventional procedures.
The ACUNAV Luxera 4D ICE system will be used adjunctively while standard-of-care transesophageal echocardiography (TEE) serves as the primary imaging modality. The study aims to determine whether 4D ICE provides comparable image quality and measurement accuracy to TEE, while maintaining procedural safety and enabling optimization of intracardiac imaging workflows.
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Walid Saliba, MD
- 電話番号:216-444-6810
- メール:salibaw@ccf.org
研究場所
-
-
Ohio
-
Cleveland、Ohio、アメリカ、44195
- 募集
- Cleveland Clinical Foundation
-
副調査官:
- Oussama Wazni, MD
-
コンタクト:
- Walid Saliba, MD
- 電話番号:216-444-6810
- メール:salibaw@ccf.org
-
-
参加基準
適格基準
就学可能な年齢
- 大人
- 高齢者
健康ボランティアの受け入れ
説明
Inclusion Criteria:
- Be aged above 18 for adult participants
- Be scheduled for a LAAO transcatheter procedure with or without concurrent procedures.
- Be able and willing to give informed consent
- (For concomitant cases only) Ablation will occur prior to LAAO implantation
Exclusion Criteria:
Potential subjects must not include:
- Subjects who are currently enrolled in any other investigational clinical studies
- Subjects with any bleeding diathesis
- Subjects with known vascular abnormality rendering right heart catheterization from right or left femoral vein impossible.
- Subjects with known intracardiac thrombus
- Subjects with myocardial infarction within the prior two months
- Subjects with class IV angina or heart failure
- Subjects with sepsis or active infection
- Subjects with immune-deficiency or immune-compromised status
- Subjects with cerebral ischemic event in the prior six months
- Subjects with deep vein thrombosis
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:診断
- 割り当て:なし
- 介入モデル:単一グループの割り当て
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:4D ICE Adjunct Imaging
Participants undergoing left atrial appendage occlusion (LAAO) procedures (with or without concomitant electrophysiology procedures) will receive adjunctive imaging using the 4D ICE catheter while TEE remains the primary imaging modality for procedural guidance.
|
Use of investigational 4D ICE catheter for real-time intracardiac imaging during cardiac interventional procedures, performed adjunctively to standard-of-care TEE guidance.
|
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Feasibility of 4D ICE Imaging Performance
時間枠:During the Procedure
|
A composite score evaluating the overall technical and clinical adequacy of the 4D Intracardiac Echocardiography (ICE) catheter compared to standard-of-care imaging. The composite score is derived from three individual component assessments: Image Quality: Clarity, resolution, and artifact presence. Anatomical Visualization: Ability to clearly identify target cardiac structures. Procedural Guidance: Effectiveness of real-time images in guiding the procedure. Each component is graded by independent reviewers on a 5-point Likert scale (1=Inadequate, 2=Suboptimal, 3=Adequate, 4=Good, 5=Excellent). The final composite score is calculated as the sum of the three component scores, ranging from a minimum of 3 (worst performance) to a maximum of 15 (best performance). |
During the Procedure
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Image Quality Assessment
時間枠:During the Procedure
|
Evaluation of 2D, 4D, and Doppler imaging quality using Likert scale (1=Inadequate, 2=Suboptimal, 3=Adequate, 4=Good, 5=Excellent).
|
During the Procedure
|
|
Workflow Efficiency
時間枠:During the Procedure
|
Procedural workflow metrics including imaging setup and acquisition time
|
During the Procedure
|
|
Measurement Acccuacy
時間枠:During the Procedure
|
Quantitative comparison of ICE-derived measurements (e.g., LAA sizing) with reference imaging (TEE or CT)
|
During the Procedure
|
|
Safety Outcomes
時間枠:Up to 45 ± 15 days follow-up
|
Incidence of device- or procedure-related adverse events
|
Up to 45 ± 15 days follow-up
|
協力者と研究者
スポンサー
捜査官
- 主任研究者:Walid Saliba, MD、The Cleveland Clinic
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- 26-552
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。