Laser Coagulation of Pilonidal Sinus With/Without Intraoperative Ultrasound Control (LCPSwUsC)
Laser Coagulation in the Treatment of Pilonidal Sinus With Intraoperative Ultrasound Control: Multicenter Prospective Randomized Trial.
LASER COAGULATION OF THE PILONIDAL SINUS WITH INTRAOPERATIVE US CONTROL: PROTOCOL FOR A PROSPECTIVE MULTICENTER RANDOMIZED CLINICAL STUDY.
Adaptive randomized controlled equivalence study with one planned non-blinded interim analysis.
調査の概要
状態
条件
詳細な説明
When analyzing the literature data, we did not find any publications that assess the quality of this operation. The technical characteristics of laser radiation, such as power, mode, amount of energy transferred, and type of fiber, are considered in all publications, which is an objective criterion. On the other hand, the surgeon's mechanical treatment and laser exposure of the internal lining of the pilonidal cyst do not have clear criteria for analysis. An intraoperative ultrasound examination can visualize the position of the surgical instrument in the sinus cavity, providing an objective confirmation of the completeness of the surgical intervention. We have proposed criteria for the quality of mechanical and laser treatment of the pilonidal sinus duct based on intraoperative ultrasound examination: the location of the instrument in the lumen of the cyst cavity; the instrument is passed along the entire length of the pilonidal sinus duct.
研究の種類
入学 (推定)
段階
- 適用できない
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
-
• chronic inflammation of the pilonidal sinus;
- sinus size according to ultrasound examination is at least 2.0 cm and no more than 9.0 cm.
- patients over 18 years of age;
- signed voluntary informed consent to participate in the study.
Exclusion Criteria:
-
• acute inflammation (abscess) of the pilonidal sinus;
- patients who have previously undergone surgery for chronic inflammation of the pilonidal sinus;
- presence of severe somatic diseases in the stage of decompensation.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:他の
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:なし(オープンラベル)
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:Active Comparator: LASER COAGULATION OF THE PILONIDAL SINUS Arm Description: performing a standar
Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the pilonidal sinus passage and secondary passages. After that, the sinus is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, without ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the sinus length. |
Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the epithelial coccygeal passage and secondary passages. After that, the cyst is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, without ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the cyst length. |
|
アクティブコンパレータ:LASER COAGULATION OF THE PILONIDAL SINUS Arm Description: performing a standar with ultrasound cont
Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing, followed by intraoperative ultrasound monitoring to confirm the placement of the sharp Volkmann spoon into the cyst lumen and the absence of false passages. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the pilonidal sinus passage and secondary passages. After that, the sinus is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, with ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the sinus length. |
Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing, followed by intraoperative ultrasound monitoring to confirm the placement of the sharp Volkmann spoon into the cyst lumen and the absence of false passages. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the epithelial coccygeal passage and secondary passages. After that, the cyst is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, with ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the cyst length. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
wound epithelization
時間枠:60 days
|
visual epithelization of all postoperative wounds by 60 days after surgery |
60 days
|
協力者と研究者
協力者
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは