Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Laser Coagulation of Pilonidal Sinus With/Without Intraoperative Ultrasound Control (LCPSwUsC)

Laser Coagulation in the Treatment of Pilonidal Sinus With Intraoperative Ultrasound Control: Multicenter Prospective Randomized Trial.

LASER COAGULATION OF THE PILONIDAL SINUS WITH INTRAOPERATIVE US CONTROL: PROTOCOL FOR A PROSPECTIVE MULTICENTER RANDOMIZED CLINICAL STUDY.

Adaptive randomized controlled equivalence study with one planned non-blinded interim analysis.

Studieoversigt

Detaljeret beskrivelse

When analyzing the literature data, we did not find any publications that assess the quality of this operation. The technical characteristics of laser radiation, such as power, mode, amount of energy transferred, and type of fiber, are considered in all publications, which is an objective criterion. On the other hand, the surgeon's mechanical treatment and laser exposure of the internal lining of the pilonidal cyst do not have clear criteria for analysis. An intraoperative ultrasound examination can visualize the position of the surgical instrument in the sinus cavity, providing an objective confirmation of the completeness of the surgical intervention. We have proposed criteria for the quality of mechanical and laser treatment of the pilonidal sinus duct based on intraoperative ultrasound examination: the location of the instrument in the lumen of the cyst cavity; the instrument is passed along the entire length of the pilonidal sinus duct.

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

310

Fase

  • Ikke anvendelig

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 60 år (Voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • • chronic inflammation of the pilonidal sinus;

    • sinus size according to ultrasound examination is at least 2.0 cm and no more than 9.0 cm.
    • patients over 18 years of age;
    • signed voluntary informed consent to participate in the study.

Exclusion Criteria:

  • • acute inflammation (abscess) of the pilonidal sinus;

    • patients who have previously undergone surgery for chronic inflammation of the pilonidal sinus;
    • presence of severe somatic diseases in the stage of decompensation.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Andet
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Aktiv komparator: Active Comparator: LASER COAGULATION OF THE PILONIDAL SINUS Arm Description: performing a standar

Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the pilonidal sinus passage and secondary passages. After that, the sinus is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, without ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the sinus length.

Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the epithelial coccygeal passage and secondary passages. After that, the cyst is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, without ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the cyst length.

Aktiv komparator: LASER COAGULATION OF THE PILONIDAL SINUS Arm Description: performing a standar with ultrasound cont

Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing, followed by intraoperative ultrasound monitoring to confirm the placement of the sharp Volkmann spoon into the cyst lumen and the absence of false passages. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the pilonidal sinus passage and secondary passages. After that, the sinus is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, with ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the sinus length.

Standard management protocol: the operation is performed under local infiltration anesthesia, with access from 1-2 points using a 4-6 mm skin trepan. Next, a button probe and a sharp Volkmann spoon are used for probing, followed by intraoperative ultrasound monitoring to confirm the placement of the sharp Volkmann spoon into the cyst lumen and the absence of false passages. Finally, the working part of the light guide is inserted, and ultrasound monitoring is performed to ensure proper orientation of the light guide throughout the epithelial coccygeal passage and secondary passages. After that, the cyst is treated with a laser having the following characteristics: wavelength 1940 nm; end-fire; power 9 W; in constant mode. Repeated mechanical and laser treatment is performed with the same laser radiation characteristics, with ultrasonic control. The calculation of the total energy (both effects) does not exceed 200 J per cm of the cyst length.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
wound epithelization
Tidsramme: 60 days

visual epithelization of all postoperative wounds by 60 days after surgery

60 days

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. september 2026

Primær færdiggørelse (Anslået)

1. september 2027

Studieafslutning (Anslået)

1. september 2028

Datoer for studieregistrering

Først indsendt

22. juni 2026

Først indsendt, der opfyldte QC-kriterier

15. september 2026

Først opslået (Faktiske)

21. september 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

21. september 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

15. september 2026

Sidst verificeret

1. september 2026

Mere information

Begreber relateret til denne undersøgelse

Yderligere relevante MeSH-vilkår

Andre undersøgelses-id-numre

  • 4444

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

INGEN

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner