このページは自動翻訳されたものであり、翻訳の正確性は保証されていません。を参照してください。 英語版 ソーステキスト用。

SafeLM Versus LMA Classic for Airway Management During Fibroadenoma Excision

2026年10月2日 更新者:Hanoi Medical University

Comparison of Airway Control Effectiveness of the SafeLM Video Laryngeal Mask and the LMA Classic in Patients Undergoing General Anesthesia for Fibroadenoma Excision

This randomized controlled trial compares the airway management performance of the SafeLM video laryngeal mask with the LMA Classic in adult patients undergoing elective fibroadenoma excision under general anesthesia. Participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic. The primary outcome is oropharyngeal leak pressure. Secondary outcomes include insertion performance, ventilation parameters, hemodynamic responses, and airway-related adverse events.

調査の概要

状態

まだ募集していません

条件

詳細な説明

The SafeLM is a video-assisted laryngeal mask that allows visualization during placement, whereas the LMA Classic is a conventional supraglottic airway device. This study is designed to compare the clinical performance of these two devices under standardized conditions.

Adult patients scheduled for elective fibroadenoma excision under general anesthesia will be screened for eligibility. Only patients for whom both devices are considered clinically appropriate will be enrolled, thereby avoiding randomization when patient characteristics indicate a preference for a particular airway management technique. Eligible participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic.

After standardized induction of general anesthesia, the assigned laryngeal mask will be inserted according to the study protocol. The primary outcome is oropharyngeal leak pressure after successful placement. Device insertion characteristics, ventilation parameters, hemodynamic responses, and airway-related adverse events will also be evaluated.

研究の種類

介入

入学 (推定)

132

段階

  • 適用できない

連絡先と場所

このセクションには、調査を実施する担当者の連絡先の詳細と、この調査が実施されている場所に関する情報が記載されています。

研究連絡先

参加基準

研究者は、適格基準と呼ばれる特定の説明に適合する人を探します。これらの基準のいくつかの例は、人の一般的な健康状態または以前の治療です。

適格基準

就学可能な年齢

18年歳以上 (大人、高齢者)

健康ボランティアの受け入れ

いいえ

受講資格のある性別

女性

説明

Inclusion Criteria:

  • Female patients aged 18 years or older.
  • Scheduled for elective excision of benign breast fibroadenoma under general anesthesia.
  • Planned airway management with a laryngeal mask airway.
  • American Society of Anesthesiologists (ASA) physical status I-II.
  • Both the SafeLM and LMA Classic are considered clinically appropriate for airway management.
  • Provision of written informed consent.

Exclusion Criteria:

  • Increased risk of pulmonary aspiration, including inadequate preoperative fasting, full stomach, or gastrointestinal obstruction.
  • Known or suspected difficult airway or other airway characteristics for which random allocation between the two study devices is considered clinically inappropriate.
  • Upper airway pathology or anatomical abnormality that may interfere with laryngeal mask placement.
  • Clinical or surgical indication requiring tracheal intubation rather than a laryngeal mask airway.
  • Contraindication or known allergy to medications used in the standardized anesthesia protocol.
  • Inability to provide informed consent.

研究計画

このセクションでは、研究がどのように設計され、研究が何を測定しているかなど、研究計画の詳細を提供します。

研究はどのように設計されていますか?

デザインの詳細

  • 主な目的:他の
  • 割り当て:ランダム化
  • 介入モデル:並列代入
  • マスキング:独身

武器と介入

参加者グループ / アーム
介入・治療
実験的:SafeLM Video Laryngeal Mask

Participants randomized to this arm will receive airway management with the SafeLM video laryngeal mask during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The SafeLM is a video-assisted supraglottic airway device that allows visualization of the laryngeal structures during insertion and positioning. It will be used for airway management during general anesthesia according to the standardized study protocol.

アクティブコンパレータ:LMA Classic

Participants randomized to this arm will receive airway management with the LMA Classic during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The LMA Classic is a conventional supraglottic airway device without video guidance. It will be used for airway management during general anesthesia according to the standardized study protocol.

この研究は何を測定していますか?

主要な結果の測定

結果測定
メジャーの説明
時間枠
Oropharyngeal Leak Pressure (OLP)
時間枠:Immediately after successful laryngeal mask placement, before the start of surgery

Oropharyngeal leak pressure will be measured after successful placement of the assigned laryngeal mask and establishment of effective ventilation. OLP will be recorded in cmH2O as the airway pressure at which an audible oropharyngeal leak is detected during a standardized leak test.

Immediately after successful laryngeal mask placement, before the start of surgery

二次結果の測定

結果測定
メジャーの説明
時間枠
First-attempt insertion success
時間枠:During initial laryngeal mask insertion

Proportion of participants in whom effective ventilation is achieved after the first insertion attempt of the assigned laryngeal mask.

During initial laryngeal mask insertion
Overall insertion success
時間枠:During laryngeal mask insertion, up to 3 attempts

Proportion of participants in whom effective ventilation is achieved with the assigned laryngeal mask within the maximum number of insertion attempts permitted by the study protocol.

During laryngeal mask insertion, up to 3 attempts
Laryngeal mask insertion time
時間枠:During laryngeal mask insertion

Time in seconds from introduction of the assigned laryngeal mask into the mouth until establishment of effective ventilation.

During laryngeal mask insertion
Number of insertion attempts
時間枠:During laryngeal mask insertion

Number of attempts required to achieve successful placement and effective ventilation with the assigned laryngeal mask.

During laryngeal mask insertion
Need for additional airway maneuvers
時間枠:During laryngeal mask insertion

Proportion of participants requiring additional maneuvers to achieve satisfactory placement and ventilation.

During laryngeal mask insertion
Peak inspiratory pressure
時間枠:At 5 and 30 minutes after successful laryngeal mask placement

Peak inspiratory airway pressure measured in cmH2O during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
End-tidal carbon dioxide
時間枠:At 5 and 30 minutes after successful laryngeal mask placement

End-tidal carbon dioxide (EtCO2) measured during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
Heart Rate
時間枠:At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Heart rate will be recorded in beats per minute (bpm).

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement
Blood staining on the laryngeal mask
時間枠:Immediately after device removal

Presence of visible blood staining on the laryngeal mask after removal.

Immediately after device removal
Postoperative sore throat
時間枠:At 1 and 24 hours after surgery

Presence of patient-reported sore throat following general anesthesia.

At 1 and 24 hours after surgery
Postoperative hoarseness
時間枠:At 1 and 24 hours after surgery

Presence of patient-reported hoarseness following general anesthesia.

At 1 and 24 hours after surgery
Airway-related adverse events
時間枠:From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery

Occurrence of airway-related adverse events, including laryngospasm and clinically evident regurgitation.

From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery
Arterial Pressure
時間枠:At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Arterial pressure will be recorded in mmHg.

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

協力者と研究者

ここでは、この調査に関係する人々や組織を見つけることができます。

スポンサー

研究記録日

これらの日付は、ClinicalTrials.gov への研究記録と要約結果の提出の進捗状況を追跡します。研究記録と報告された結果は、国立医学図書館 (NLM) によって審査され、公開 Web サイトに掲載される前に、特定の品質管理基準を満たしていることが確認されます。

主要日程の研究

研究開始 (推定)

2026年10月1日

一次修了 (推定)

2027年6月1日

研究の完了 (推定)

2027年7月1日

試験登録日

最初に提出

2026年9月16日

QC基準を満たした最初の提出物

2026年9月16日

最初の投稿 (実際)

2026年9月23日

学習記録の更新

投稿された最後の更新 (実際)

2026年10月7日

QC基準を満たした最後の更新が送信されました

2026年10月2日

最終確認日

2026年9月1日

詳しくは

本研究に関する用語

個々の参加者データ (IPD) の計画

個々の参加者データ (IPD) を共有する予定はありますか?

いいえ

医薬品およびデバイス情報、研究文書

米国FDA規制医薬品の研究

いいえ

米国FDA規制機器製品の研究

いいえ

米国で製造され、米国から輸出された製品。

いいえ

この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。

購読する