Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

SafeLM Versus LMA Classic for Airway Management During Fibroadenoma Excision

2 de outubro de 2026 atualizado por: Hanoi Medical University

Comparison of Airway Control Effectiveness of the SafeLM Video Laryngeal Mask and the LMA Classic in Patients Undergoing General Anesthesia for Fibroadenoma Excision

This randomized controlled trial compares the airway management performance of the SafeLM video laryngeal mask with the LMA Classic in adult patients undergoing elective fibroadenoma excision under general anesthesia. Participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic. The primary outcome is oropharyngeal leak pressure. Secondary outcomes include insertion performance, ventilation parameters, hemodynamic responses, and airway-related adverse events.

Visão geral do estudo

Status

Ainda não está recrutando

Descrição detalhada

The SafeLM is a video-assisted laryngeal mask that allows visualization during placement, whereas the LMA Classic is a conventional supraglottic airway device. This study is designed to compare the clinical performance of these two devices under standardized conditions.

Adult patients scheduled for elective fibroadenoma excision under general anesthesia will be screened for eligibility. Only patients for whom both devices are considered clinically appropriate will be enrolled, thereby avoiding randomization when patient characteristics indicate a preference for a particular airway management technique. Eligible participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic.

After standardized induction of general anesthesia, the assigned laryngeal mask will be inserted according to the study protocol. The primary outcome is oropharyngeal leak pressure after successful placement. Device insertion characteristics, ventilation parameters, hemodynamic responses, and airway-related adverse events will also be evaluated.

Tipo de estudo

Intervencional

Inscrição (Estimado)

132

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Contato de estudo

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos e mais velhos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Fêmea

Descrição

Inclusion Criteria:

  • Female patients aged 18 years or older.
  • Scheduled for elective excision of benign breast fibroadenoma under general anesthesia.
  • Planned airway management with a laryngeal mask airway.
  • American Society of Anesthesiologists (ASA) physical status I-II.
  • Both the SafeLM and LMA Classic are considered clinically appropriate for airway management.
  • Provision of written informed consent.

Exclusion Criteria:

  • Increased risk of pulmonary aspiration, including inadequate preoperative fasting, full stomach, or gastrointestinal obstruction.
  • Known or suspected difficult airway or other airway characteristics for which random allocation between the two study devices is considered clinically inappropriate.
  • Upper airway pathology or anatomical abnormality that may interfere with laryngeal mask placement.
  • Clinical or surgical indication requiring tracheal intubation rather than a laryngeal mask airway.
  • Contraindication or known allergy to medications used in the standardized anesthesia protocol.
  • Inability to provide informed consent.

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Outro
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Solteiro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: SafeLM Video Laryngeal Mask

Participants randomized to this arm will receive airway management with the SafeLM video laryngeal mask during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The SafeLM is a video-assisted supraglottic airway device that allows visualization of the laryngeal structures during insertion and positioning. It will be used for airway management during general anesthesia according to the standardized study protocol.

Comparador Ativo: LMA Classic

Participants randomized to this arm will receive airway management with the LMA Classic during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The LMA Classic is a conventional supraglottic airway device without video guidance. It will be used for airway management during general anesthesia according to the standardized study protocol.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Oropharyngeal Leak Pressure (OLP)
Prazo: Immediately after successful laryngeal mask placement, before the start of surgery

Oropharyngeal leak pressure will be measured after successful placement of the assigned laryngeal mask and establishment of effective ventilation. OLP will be recorded in cmH2O as the airway pressure at which an audible oropharyngeal leak is detected during a standardized leak test.

Immediately after successful laryngeal mask placement, before the start of surgery

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
First-attempt insertion success
Prazo: During initial laryngeal mask insertion

Proportion of participants in whom effective ventilation is achieved after the first insertion attempt of the assigned laryngeal mask.

During initial laryngeal mask insertion
Overall insertion success
Prazo: During laryngeal mask insertion, up to 3 attempts

Proportion of participants in whom effective ventilation is achieved with the assigned laryngeal mask within the maximum number of insertion attempts permitted by the study protocol.

During laryngeal mask insertion, up to 3 attempts
Laryngeal mask insertion time
Prazo: During laryngeal mask insertion

Time in seconds from introduction of the assigned laryngeal mask into the mouth until establishment of effective ventilation.

During laryngeal mask insertion
Number of insertion attempts
Prazo: During laryngeal mask insertion

Number of attempts required to achieve successful placement and effective ventilation with the assigned laryngeal mask.

During laryngeal mask insertion
Need for additional airway maneuvers
Prazo: During laryngeal mask insertion

Proportion of participants requiring additional maneuvers to achieve satisfactory placement and ventilation.

During laryngeal mask insertion
Peak inspiratory pressure
Prazo: At 5 and 30 minutes after successful laryngeal mask placement

Peak inspiratory airway pressure measured in cmH2O during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
End-tidal carbon dioxide
Prazo: At 5 and 30 minutes after successful laryngeal mask placement

End-tidal carbon dioxide (EtCO2) measured during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
Heart Rate
Prazo: At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Heart rate will be recorded in beats per minute (bpm).

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement
Blood staining on the laryngeal mask
Prazo: Immediately after device removal

Presence of visible blood staining on the laryngeal mask after removal.

Immediately after device removal
Postoperative sore throat
Prazo: At 1 and 24 hours after surgery

Presence of patient-reported sore throat following general anesthesia.

At 1 and 24 hours after surgery
Postoperative hoarseness
Prazo: At 1 and 24 hours after surgery

Presence of patient-reported hoarseness following general anesthesia.

At 1 and 24 hours after surgery
Airway-related adverse events
Prazo: From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery

Occurrence of airway-related adverse events, including laryngospasm and clinically evident regurgitation.

From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery
Arterial Pressure
Prazo: At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Arterial pressure will be recorded in mmHg.

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Estimado)

1 de outubro de 2026

Conclusão Primária (Estimado)

1 de junho de 2027

Conclusão do estudo (Estimado)

1 de julho de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

16 de setembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

16 de setembro de 2026

Primeira postagem (Real)

23 de setembro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

7 de outubro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

2 de outubro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

produto fabricado e exportado dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .