Denne siden ble automatisk oversatt og nøyaktigheten av oversettelsen er ikke garantert. Vennligst referer til engelsk versjon for en kildetekst.

SafeLM Versus LMA Classic for Airway Management During Fibroadenoma Excision

2. oktober 2026 oppdatert av: Hanoi Medical University

Comparison of Airway Control Effectiveness of the SafeLM Video Laryngeal Mask and the LMA Classic in Patients Undergoing General Anesthesia for Fibroadenoma Excision

This randomized controlled trial compares the airway management performance of the SafeLM video laryngeal mask with the LMA Classic in adult patients undergoing elective fibroadenoma excision under general anesthesia. Participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic. The primary outcome is oropharyngeal leak pressure. Secondary outcomes include insertion performance, ventilation parameters, hemodynamic responses, and airway-related adverse events.

Studieoversikt

Status

Har ikke rekruttert ennå

Forhold

Detaljert beskrivelse

The SafeLM is a video-assisted laryngeal mask that allows visualization during placement, whereas the LMA Classic is a conventional supraglottic airway device. This study is designed to compare the clinical performance of these two devices under standardized conditions.

Adult patients scheduled for elective fibroadenoma excision under general anesthesia will be screened for eligibility. Only patients for whom both devices are considered clinically appropriate will be enrolled, thereby avoiding randomization when patient characteristics indicate a preference for a particular airway management technique. Eligible participants will be randomly assigned to airway management with either the SafeLM or the LMA Classic.

After standardized induction of general anesthesia, the assigned laryngeal mask will be inserted according to the study protocol. The primary outcome is oropharyngeal leak pressure after successful placement. Device insertion characteristics, ventilation parameters, hemodynamic responses, and airway-related adverse events will also be evaluated.

Studietype

Intervensjonell

Registrering (Antatt)

132

Fase

  • Ikke aktuelt

Kontakter og plasseringer

Denne delen inneholder kontaktinformasjon for de som utfører studien, og informasjon om hvor denne studien blir utført.

Studiekontakt

Deltakelseskriterier

Forskere ser etter personer som passer til en bestemt beskrivelse, kalt kvalifikasjonskriterier. Noen eksempler på disse kriteriene er en persons generelle helsetilstand eller tidligere behandlinger.

Kvalifikasjonskriterier

Alder som er kvalifisert for studier

18 år og eldre (Voksen, Eldre voksen)

Tar imot friske frivillige

Nei

Kjønn som er kvalifisert for studier

Hunn

Beskrivelse

Inclusion Criteria:

  • Female patients aged 18 years or older.
  • Scheduled for elective excision of benign breast fibroadenoma under general anesthesia.
  • Planned airway management with a laryngeal mask airway.
  • American Society of Anesthesiologists (ASA) physical status I-II.
  • Both the SafeLM and LMA Classic are considered clinically appropriate for airway management.
  • Provision of written informed consent.

Exclusion Criteria:

  • Increased risk of pulmonary aspiration, including inadequate preoperative fasting, full stomach, or gastrointestinal obstruction.
  • Known or suspected difficult airway or other airway characteristics for which random allocation between the two study devices is considered clinically inappropriate.
  • Upper airway pathology or anatomical abnormality that may interfere with laryngeal mask placement.
  • Clinical or surgical indication requiring tracheal intubation rather than a laryngeal mask airway.
  • Contraindication or known allergy to medications used in the standardized anesthesia protocol.
  • Inability to provide informed consent.

Studieplan

Denne delen gir detaljer om studieplanen, inkludert hvordan studien er utformet og hva studien måler.

Hvordan er studiet utformet?

Designdetaljer

  • Primært formål: Annen
  • Tildeling: Randomisert
  • Intervensjonsmodell: Parallell tildeling
  • Masking: Enkelt

Våpen og intervensjoner

Deltakergruppe / Arm
Intervensjon / Behandling
Eksperimentell: SafeLM Video Laryngeal Mask

Participants randomized to this arm will receive airway management with the SafeLM video laryngeal mask during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The SafeLM is a video-assisted supraglottic airway device that allows visualization of the laryngeal structures during insertion and positioning. It will be used for airway management during general anesthesia according to the standardized study protocol.

Aktiv komparator: LMA Classic

Participants randomized to this arm will receive airway management with the LMA Classic during general anesthesia for elective fibroadenoma excision. The device will be inserted according to the standardized study protocol.

The LMA Classic is a conventional supraglottic airway device without video guidance. It will be used for airway management during general anesthesia according to the standardized study protocol.

Hva måler studien?

Primære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
Oropharyngeal Leak Pressure (OLP)
Tidsramme: Immediately after successful laryngeal mask placement, before the start of surgery

Oropharyngeal leak pressure will be measured after successful placement of the assigned laryngeal mask and establishment of effective ventilation. OLP will be recorded in cmH2O as the airway pressure at which an audible oropharyngeal leak is detected during a standardized leak test.

Immediately after successful laryngeal mask placement, before the start of surgery

Sekundære resultatmål

Resultatmål
Tiltaksbeskrivelse
Tidsramme
First-attempt insertion success
Tidsramme: During initial laryngeal mask insertion

Proportion of participants in whom effective ventilation is achieved after the first insertion attempt of the assigned laryngeal mask.

During initial laryngeal mask insertion
Overall insertion success
Tidsramme: During laryngeal mask insertion, up to 3 attempts

Proportion of participants in whom effective ventilation is achieved with the assigned laryngeal mask within the maximum number of insertion attempts permitted by the study protocol.

During laryngeal mask insertion, up to 3 attempts
Laryngeal mask insertion time
Tidsramme: During laryngeal mask insertion

Time in seconds from introduction of the assigned laryngeal mask into the mouth until establishment of effective ventilation.

During laryngeal mask insertion
Number of insertion attempts
Tidsramme: During laryngeal mask insertion

Number of attempts required to achieve successful placement and effective ventilation with the assigned laryngeal mask.

During laryngeal mask insertion
Need for additional airway maneuvers
Tidsramme: During laryngeal mask insertion

Proportion of participants requiring additional maneuvers to achieve satisfactory placement and ventilation.

During laryngeal mask insertion
Peak inspiratory pressure
Tidsramme: At 5 and 30 minutes after successful laryngeal mask placement

Peak inspiratory airway pressure measured in cmH2O during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
End-tidal carbon dioxide
Tidsramme: At 5 and 30 minutes after successful laryngeal mask placement

End-tidal carbon dioxide (EtCO2) measured during mechanical ventilation.

At 5 and 30 minutes after successful laryngeal mask placement
Heart Rate
Tidsramme: At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Heart rate will be recorded in beats per minute (bpm).

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement
Blood staining on the laryngeal mask
Tidsramme: Immediately after device removal

Presence of visible blood staining on the laryngeal mask after removal.

Immediately after device removal
Postoperative sore throat
Tidsramme: At 1 and 24 hours after surgery

Presence of patient-reported sore throat following general anesthesia.

At 1 and 24 hours after surgery
Postoperative hoarseness
Tidsramme: At 1 and 24 hours after surgery

Presence of patient-reported hoarseness following general anesthesia.

At 1 and 24 hours after surgery
Airway-related adverse events
Tidsramme: From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery

Occurrence of airway-related adverse events, including laryngospasm and clinically evident regurgitation.

From laryngeal mask insertion through postoperative observation, assessed up to 24 hours after surgery
Arterial Pressure
Tidsramme: At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Arterial pressure will be recorded in mmHg.

At baseline, immediately after successful laryngeal mask placement, and at 5 and 30 minutes after placement

Samarbeidspartnere og etterforskere

Det er her du vil finne personer og organisasjoner som er involvert i denne studien.

Studierekorddatoer

Disse datoene sporer fremdriften for innsending av studieposter og sammendragsresultater til ClinicalTrials.gov. Studieposter og rapporterte resultater gjennomgås av National Library of Medicine (NLM) for å sikre at de oppfyller spesifikke kvalitetskontrollstandarder før de legges ut på det offentlige nettstedet.

Studer hoveddatoer

Studiestart (Antatt)

1. oktober 2026

Primær fullføring (Antatt)

1. juni 2027

Studiet fullført (Antatt)

1. juli 2027

Datoer for studieregistrering

Først innsendt

16. september 2026

Først innsendt som oppfylte QC-kriteriene

16. september 2026

Først lagt ut (Faktiske)

23. september 2026

Oppdateringer av studieposter

Sist oppdatering lagt ut (Faktiske)

7. oktober 2026

Siste oppdatering sendt inn som oppfylte QC-kriteriene

2. oktober 2026

Sist bekreftet

1. september 2026

Mer informasjon

Begreper knyttet til denne studien

Plan for individuelle deltakerdata (IPD)

Planlegger du å dele individuelle deltakerdata (IPD)?

NEI

Legemiddel- og utstyrsinformasjon, studiedokumenter

Studerer et amerikansk FDA-regulert medikamentprodukt

Nei

Studerer et amerikansk FDA-regulert enhetsprodukt

Nei

produkt produsert i og eksportert fra USA

Nei

Denne informasjonen ble hentet direkte fra nettstedet clinicaltrials.gov uten noen endringer. Hvis du har noen forespørsler om å endre, fjerne eller oppdatere studiedetaljene dine, vennligst kontakt register@clinicaltrials.gov. Så snart en endring er implementert på clinicaltrials.gov, vil denne også bli oppdatert automatisk på nettstedet vårt. .

Abonnere