Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair
Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial
The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.
調査の概要
状態
詳細な説明
Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.
In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.
In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.
The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.
研究の種類
入学 (実際)
段階
- 適用できない
連絡先と場所
研究場所
-
-
Erzurum
-
Erzurum、Erzurum、トルコ(Türkiye)、25240
- Ataturk University Education and Research Hospital
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age between 18 and 80 years
- Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
- Goutallier fatty infiltration grade 1 or 2
- Written informed consent
Exclusion Criteria:
- Massive rotator cuff tear
- Advanced glenohumeral osteoarthritis
- Previous open shoulder surgery
- Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Fibrin Clot Group
Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.
他の名前:
|
|
アクティブコンパレータ:Control Group
Standard arthroscopic rotator cuff repair without fibrin clot augmentation. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
時間枠:12 months postoperatively
|
Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups. |
12 months postoperatively
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
American Shoulder and Elbow Surgeons (ASES) Score
時間枠:Preoperatively and at 3, 6 and 12 months postoperatively
|
Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
その他の成果指標
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Constant-Murley Score
時間枠:Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
|
Visual Analog Scale (VAS) for Pain
時間枠:Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
協力者と研究者
スポンサー
出版物と役立つリンク
研究記録日
主要日程の研究
研究開始 (実際)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
キーワード
追加の関連 MeSH 用語
その他の研究ID番号
- ATAUNI-KAEK-2025-10
- 2025-10 (その他の識別子:Ataturk University Clinical Research Ethics Committee Decision Number)
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。