Esta página foi traduzida automaticamente e a precisão da tradução não é garantida. Por favor, consulte o versão em inglês para um texto fonte.

Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair

27 de setembro de 2026 atualizado por: Ebubekir Safa Budak, Ataturk University

Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial

The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.

Visão geral do estudo

Descrição detalhada

Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.

In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.

In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.

The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.

Tipo de estudo

Intervencional

Inscrição (Real)

50

Estágio

  • Não aplicável

Contactos e Locais

Esta seção fornece os detalhes de contato para aqueles que conduzem o estudo e informações sobre onde este estudo está sendo realizado.

Locais de estudo

    • Erzurum
      • Erzurum, Erzurum, Turquia (Türkiye), 25240
        • Ataturk University Education and Research Hospital

Critérios de participação

Os pesquisadores procuram pessoas que se encaixem em uma determinada descrição, chamada de critérios de elegibilidade. Alguns exemplos desses critérios são a condição geral de saúde de uma pessoa ou tratamentos anteriores.

Critérios de elegibilidade

Idades elegíveis para estudo

18 anos a 80 anos (Adulto, Adulto mais velho)

Aceita Voluntários Saudáveis

Não

Gêneros Elegíveis para o Estudo

Tudo

Descrição

Inclusion Criteria:

  • Age between 18 and 80 years
  • Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
  • Goutallier fatty infiltration grade 1 or 2
  • Written informed consent

Exclusion Criteria:

  • Massive rotator cuff tear
  • Advanced glenohumeral osteoarthritis
  • Previous open shoulder surgery
  • Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)

Plano de estudo

Esta seção fornece detalhes do plano de estudo, incluindo como o estudo é projetado e o que o estudo está medindo.

Como o estudo é projetado?

Detalhes do projeto

  • Finalidade Principal: Tratamento
  • Alocação: Randomizado
  • Modelo Intervencional: Atribuição Paralela
  • Mascaramento: Dobro

Armas e Intervenções

Grupo de Participantes / Braço
Intervenção / Tratamento
Experimental: Fibrin Clot Group

Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface.

Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors.

40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.

Outros nomes:
  • Endogenous Fibrin Clot
Comparador Ativo: Control Group

Standard arthroscopic rotator cuff repair without fibrin clot augmentation.

Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors.

O que o estudo está medindo?

Medidas de resultados primários

Medida de resultado
Descrição da medida
Prazo
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
Prazo: 12 months postoperatively

Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups.

12 months postoperatively

Medidas de resultados secundários

Medida de resultado
Descrição da medida
Prazo
American Shoulder and Elbow Surgeons (ASES) Score
Prazo: Preoperatively and at 3, 6 and 12 months postoperatively

Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function.

Preoperatively and at 3, 6 and 12 months postoperatively

Outras medidas de resultado

Medida de resultado
Descrição da medida
Prazo
Constant-Murley Score
Prazo: Preoperatively and at 3, 6 and 12 months postoperatively

Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function.

Preoperatively and at 3, 6 and 12 months postoperatively
Visual Analog Scale (VAS) for Pain
Prazo: Preoperatively and at 3, 6 and 12 months postoperatively

Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain.

Preoperatively and at 3, 6 and 12 months postoperatively

Colaboradores e Investigadores

É aqui que você encontrará pessoas e organizações envolvidas com este estudo.

Patrocinador

Publicações e links úteis

A pessoa responsável por inserir informações sobre o estudo fornece voluntariamente essas publicações. Estes podem ser sobre qualquer coisa relacionada ao estudo.

Datas de registro do estudo

Essas datas acompanham o progresso do registro do estudo e os envios de resumo dos resultados para ClinicalTrials.gov. Os registros do estudo e os resultados relatados são revisados ​​pela National Library of Medicine (NLM) para garantir que atendam aos padrões específicos de controle de qualidade antes de serem publicados no site público.

Datas Principais do Estudo

Início do estudo (Real)

15 de novembro de 2025

Conclusão Primária (Estimado)

28 de fevereiro de 2027

Conclusão do estudo (Estimado)

28 de fevereiro de 2027

Datas de inscrição no estudo

Enviado pela primeira vez

27 de setembro de 2026

Enviado pela primeira vez que atendeu aos critérios de CQ

27 de setembro de 2026

Primeira postagem (Real)

2 de outubro de 2026

Atualizações de registro de estudo

Última Atualização Postada (Real)

2 de outubro de 2026

Última atualização enviada que atendeu aos critérios de controle de qualidade

27 de setembro de 2026

Última verificação

1 de setembro de 2026

Mais Informações

Termos relacionados a este estudo

Outros números de identificação do estudo

  • ATAUNI-KAEK-2025-10
  • 2025-10 (Outro identificador: Ataturk University Clinical Research Ethics Committee Decision Number)

Plano para dados de participantes individuais (IPD)

Planeja compartilhar dados de participantes individuais (IPD)?

NÃO

Descrição do plano IPD

Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.

Informações sobre medicamentos e dispositivos, documentos de estudo

Estuda um medicamento regulamentado pela FDA dos EUA

Não

Estuda um produto de dispositivo regulamentado pela FDA dos EUA

Não

Essas informações foram obtidas diretamente do site clinicaltrials.gov sem nenhuma alteração. Se você tiver alguma solicitação para alterar, remover ou atualizar os detalhes do seu estudo, entre em contato com register@clinicaltrials.gov. Assim que uma alteração for implementada em clinicaltrials.gov, ela também será atualizada automaticamente em nosso site .

Se inscrever