- ICH GCP
- Amerikanska kliniska prövningsregistret
- Klinisk prövning NCT07853950
Fibrin Clot Augmentation in Arthroscopic Rotator Cuff Repair
Evaluation of the Efficacy of Autologous Fibrin Clot Applied to the Repair Interface in Arthroscopic Treatment of Rotator Cuff Tears: A Prospective, Randomized, Double-Blind Controlled Trial
The aim of this study is to evaluate whether applying an autologous fibrin clot to the repair site improves tendon healing and clinical outcomes after arthroscopic rotator cuff repair. Fifty patients with rotator cuff tears requiring surgery were randomly assigned to two groups: arthroscopic repair with autologous fibrin clot augmentation or standard arthroscopic repair alone. The fibrin clot is prepared from the patient's own blood without centrifugation. Tendon healing is assessed with magnetic resonance imaging (MRI) using the Sugaya classification at 12 months, and shoulder function and pain are assessed with the ASES score, Constant score and Visual Analog Scale (VAS) preoperatively and at 3, 6 and 12 months.
Studieöversikt
Status
Betingelser
Intervention / Behandling
Detaljerad beskrivning
Rotator cuff tears are a common cause of shoulder pain and dysfunction, and retear after surgical repair remains a significant problem. Biological augmentation strategies aim to enhance healing at the tendon-bone interface. Autologous fibrin clot is a simple, low-cost biological augment that provides a fibrin scaffold containing platelets and growth factors, and it can be prepared intraoperatively without centrifugation or commercial kits.
In this prospective, randomized, double-blind controlled trial, 50 patients aged 18-80 years with full-thickness or partial-thickness rotator cuff tears (Goutallier fatty infiltration grade 1 or 2) and an indication for surgical repair were randomly allocated in a 1:1 ratio using a computer-generated randomization sequence to either the fibrin clot group (n=25) or the control group (n=25). Patients and outcome assessors are blinded to group allocation.
In the fibrin clot group, 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms. The clot is then delivered arthroscopically to the tendon-bone repair interface. The control group undergoes the same arthroscopic rotator cuff repair without fibrin clot application. Both groups follow the same postoperative rehabilitation protocol.
The primary outcome is rotator cuff repair integrity evaluated with MRI according to the Sugaya classification at 12 months postoperatively. Secondary outcomes are ASES score, Constant score and VAS pain score, assessed preoperatively and at 3, 6 and 12 months postoperatively.
Studietyp
Inskrivning (Faktisk)
Fas
- Inte tillämpbar
Kontakter och platser
Studieorter
-
-
Erzurum
-
Erzurum, Erzurum, Turkiet (Türkiye), 25240
- Ataturk University Education and Research Hospital
-
-
Deltagandekriterier
Urvalskriterier
Åldrar som är berättigade till studier
Tar emot friska volontärer
Kön som är behöriga för studier
Beskrivning
Inclusion Criteria:
- Age between 18 and 80 years
- Full-thickness or partial-thickness rotator cuff tear with an indication for arthroscopic surgical repair
- Goutallier fatty infiltration grade 1 or 2
- Written informed consent
Exclusion Criteria:
- Massive rotator cuff tear
- Advanced glenohumeral osteoarthritis
- Previous open shoulder surgery
- Serious comorbid disease (e.g., uncontrolled diabetes mellitus, advanced rheumatoid arthritis)
Studieplan
Hur är studien utformad?
Designdetaljer
- Primärt syfte: Behandling
- Tilldelning: Randomiserad
- Interventionsmodell: Parallellt uppdrag
- Maskning: Dubbel
Vapen och interventioner
Deltagargrupp / Arm |
Intervention / Behandling |
|---|---|
|
Experimentell: Fibrin Clot Group
Arthroscopic rotator cuff repair augmented with an autologous fibrin clot applied to the tendon-bone repair interface. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. 40 mL of venous blood is drawn from the patient during surgery and stirred with a sterile glass rod until a fibrin clot forms, without centrifugation. The clot is delivered arthroscopically to the tendon-bone repair interface.
Andra namn:
|
|
Aktiv komparator: Control Group
Standard arthroscopic rotator cuff repair without fibrin clot augmentation. |
Standard arthroscopic repair of the torn rotator cuff tendon to its footprint using suture anchors. |
Vad mäter studien?
Primära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Rotator Cuff Repair Integrity on MRI (Sugaya Classification)
Tidsram: 12 months postoperatively
|
Repair integrity is evaluated with magnetic resonance imaging and classified according to the Sugaya classification (Type I to V). Types I-III are considered healed and Types IV-V are considered retear. The proportion of healed repairs and the retear rate are compared between groups. |
12 months postoperatively
|
Sekundära resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
American Shoulder and Elbow Surgeons (ASES) Score
Tidsram: Preoperatively and at 3, 6 and 12 months postoperatively
|
Patient-reported shoulder pain and function score ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Andra resultatmått
Resultatmått |
Åtgärdsbeskrivning |
Tidsram |
|---|---|---|
|
Constant-Murley Score
Tidsram: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder function score including pain, activities of daily living, range of motion and strength, ranging from 0 to 100, with higher scores indicating better shoulder function. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
|
Visual Analog Scale (VAS) for Pain
Tidsram: Preoperatively and at 3, 6 and 12 months postoperatively
|
Shoulder pain intensity measured on a 0-10 scale, with 0 indicating no pain and 10 indicating the worst imaginable pain. |
Preoperatively and at 3, 6 and 12 months postoperatively
|
Samarbetspartners och utredare
Sponsor
Publikationer och användbara länkar
Studieavstämningsdatum
Studera stora datum
Studiestart (Faktisk)
Primärt slutförande (Beräknad)
Avslutad studie (Beräknad)
Studieregistreringsdatum
Först inskickad
Först inskickad som uppfyllde QC-kriterierna
Första postat (Faktisk)
Uppdateringar av studier
Senaste uppdatering publicerad (Faktisk)
Senaste inskickade uppdateringen som uppfyllde QC-kriterierna
Senast verifierad
Mer information
Termer relaterade till denna studie
Nyckelord
Ytterligare relevanta MeSH-villkor
Andra studie-ID-nummer
- ATAUNI-KAEK-2025-10
- 2025-10 (Annan identifierare: Ataturk University Clinical Research Ethics Committee Decision Number)
Plan för individuella deltagardata (IPD)
Planerar du att dela individuella deltagardata (IPD)?
IPD-planbeskrivning
Individual participant data will not be publicly shared due to patient confidentiality. De-identified data may be made available by the principal investigator upon reasonable request.
Läkemedels- och apparatinformation, studiedokument
Studerar en amerikansk FDA-reglerad läkemedelsprodukt
Studerar en amerikansk FDA-reglerad produktprodukt
Denna information hämtades direkt från webbplatsen clinicaltrials.gov utan några ändringar. Om du har några önskemål om att ändra, ta bort eller uppdatera dina studieuppgifter, vänligen kontakta register@clinicaltrials.gov. Så snart en ändring har implementerats på clinicaltrials.gov, kommer denna att uppdateras automatiskt även på vår webbplats .