Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs
Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs (A Controlled Clinical Trial)
Implant-supported prostheses have become a popular treatment option in clinical dentistry because of their long-term clinical success rates and their proven functional, biological, and mechanical advantages.
Dental implants exhibit biomechanical behavior that differs from that of natural teeth because implants lack periodontal ligaments and are in direct contact with bone. Consequently, the occlusal loads received by the implant are transferred directly to the surrounding bone structure. This relationship affects stress distribution within the implant and the peripheral bone and is considered one of the major factors determining implant success. The transfer of stress or energy between the implant and the surrounding bone is influenced by several factors, including the direction of loading and the design and material characteristics of both the implant and the restorative crown.
Soft-tissue attachment around dental implants resembles that around natural teeth, as it includes junctional epithelium and connective tissue fibers. However, some important differences exist. The connective tissue fibers surrounding implants are oriented parallel rather than perpendicular to the implant surface, and the connective tissue around implants is less vascular than that surrounding natural tooth. The formation and maturation of the peri-implant soft-tissue complex require sufficient healing time. Stable soft-tissue attachment is essential for maintaining osseointegration and protecting the underlying peri-implant bone.
Several major factors influence osseointegration, including implant material, implant design, implant surface finish, bone condition, surgical technique, and implant-loading conditions. The first three factors-implant material, macro-design, and micro-surface characteristics-are directly related to the implant itself and may vary according to the manufacturing process.
The macro-design of dental implants may vary considerably, and several aspects of implant geometry can affect treatment outcomes. The implant design should provide adequate primary stability without causing excessive trauma to the osteotomy site, which may result in bone necrosis. It should also contribute to achieving an effective seal at the implant-abutment junction to preserve the integrity of the marginal soft tissues and reduce the risk of mechanical and biological complications. Furthermore, implant design should support the preservation of marginal bone levels during the initial physiological remodeling phase.
Peak horizontal and vertical loading forces are commonly concentrated at the crestal bone level. Therefore, modifications to the implant collar and thread design have been introduced to improve stress distribution and preserve marginal bone. Microthreads at the implant collar, particularly when combined with an internal conical implant-abutment connection, may contribute to improved biomechanical behavior and better maintenance of peri-implant tissues. Surface modifications have also been introduced to enhance osseointegration. These modifications may be achieved chemically by incorporating inorganic or organic components or physically by altering the surface topography at the micrometer or nanometer level.
A dental implant restoration generally consists of three main components: the implant fixture, an abutment that facilitates the support and retention of the restoration, and the final prosthetic restoration. Provisional restorations play an important role in soft-tissue management around implants. A properly finished and polished provisional crown can help establish a healthy peri-implant soft-tissue contour and provide appropriate support for the gingival margin. The decision regarding the timing and type of provisionalization should consider the expected changes in the facial gingival margin and the need to maintain soft-tissue architecture.
Polyetheretherketone is a synthetic thermoplastic polymer characterized by high mechanical performance and has been used as a biomaterial in various medical applications. A modified form of this material, known as BioHPP, has been specifically optimized for dental applications. It is reinforced with ceramic fillers to improve its mechanical properties and make it suitable for the fabrication of crowns and fixed prostheses.
Monolithic zirconia restorations represent another treatment option. These restorations are milled from solid zirconia blocks and may be individually stained to reproduce the appearance of enamel and gingival tissues. Zirconia provides favorable esthetic properties, particularly because it eliminates the dark cervical line that may occur with metal-based restorations. It is also characterized by high strength, durability, wear resistance, and a low risk of chipping or crack formation.
The differences in the elastic modulus, rigidity, and stress-absorbing capacity of PEEK and zirconia may influence the transmission of occlusal forces to dental implants and the surround
調査の概要
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:kareem mohamed abdel motaleb, master degree
- 電話番号:201005335831
- メール:kareemabdelmotaleb@yahoo.com
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Age range of the patients from 35-50 years old
- Patients able physically and psychologically implant placement
- patients are medically free.
- Presence of teeth in opposite arch with normal occlusal relation.
- Patient with masticatory forces within the normal range
- Patient with normal muscel tone to avoid bruxer patient and it will be assessed using the electromyograph
- Supra-gingival margin after preparation.
- Patients willing to return for follow-up examinations and evaluation.
- D2 or D3 bone quality will be preferred
Exclusion Criteria:
- Smoking patients.
- Patients with poor oral hygiene and motivation.
- Patients with parafunctional habits.
- D1 and D4 bone quality will be excluded
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:ダブル
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
アクティブコンパレータ:first implant design
first implant design |
PEEK crown zirconia crown |
|
実験的:second implant design
second implant design |
PEEK crown zirconia crown |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
crestal bone loss
時間枠:1 year
|
Intraoral X-rays will be made using the long-cone parallel technique for the two groups. All radiographs were digitized for evaluation of the bone levels (BL) at different time points. The marginal BL was determined by measuring the distance between the implant shoulder (reference) and the most coronal bone-to implant contact. These measurements were made by two independent examiners mesially and distally of the implants and in 0.1-mm increments |
1 year
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
gingival index
時間枠:1 year
|
Gingival index of the two groups will be assessed by the Loe & Silness gingival index as follow: Grade 0: (Normal gingival) Natural coral pink gingival. Grade 1: (Mild inflammation) Slight change in color, slight edema. No bleeding on probing. Grade 2: (Moderate inflammation) Redness, edema and glazing. Bleeding on probing. Grade 3: (Severe inflammation) Marked redness and edema. Tendency to spontaneous bleeding. Ulceration. |
1 year
|
|
probing depth
時間枠:1 year
|
Probing pocket depth (PPD) for the two groups will be measured from the mucosal margin to the bottom of the probeable pocket in millimeters with a periodontal probe (PCB 12; Hu-Friedy, Leimen, Germany) at four aspects per implant mesial distal buccal lingual The subscales will be summed and an average will be taken. |
1 year
|
協力者と研究者
出版物と役立つリンク
一般刊行物
- R.M. Kamal et al. / Al-Azhar Journal of Dentistry 11 (2024) 27e31
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
その他の研究ID番号
- serial number of 1006
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
米国で製造され、米国から輸出された製品。
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。