- ICH GCP
- US-Register für klinische Studien
- Klinische Studie NCT07943351
Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs
Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs (A Controlled Clinical Trial)
Implant-supported prostheses have become a popular treatment option in clinical dentistry because of their long-term clinical success rates and their proven functional, biological, and mechanical advantages.
Dental implants exhibit biomechanical behavior that differs from that of natural teeth because implants lack periodontal ligaments and are in direct contact with bone. Consequently, the occlusal loads received by the implant are transferred directly to the surrounding bone structure. This relationship affects stress distribution within the implant and the peripheral bone and is considered one of the major factors determining implant success. The transfer of stress or energy between the implant and the surrounding bone is influenced by several factors, including the direction of loading and the design and material characteristics of both the implant and the restorative crown.
Soft-tissue attachment around dental implants resembles that around natural teeth, as it includes junctional epithelium and connective tissue fibers. However, some important differences exist. The connective tissue fibers surrounding implants are oriented parallel rather than perpendicular to the implant surface, and the connective tissue around implants is less vascular than that surrounding natural tooth. The formation and maturation of the peri-implant soft-tissue complex require sufficient healing time. Stable soft-tissue attachment is essential for maintaining osseointegration and protecting the underlying peri-implant bone.
Several major factors influence osseointegration, including implant material, implant design, implant surface finish, bone condition, surgical technique, and implant-loading conditions. The first three factors-implant material, macro-design, and micro-surface characteristics-are directly related to the implant itself and may vary according to the manufacturing process.
The macro-design of dental implants may vary considerably, and several aspects of implant geometry can affect treatment outcomes. The implant design should provide adequate primary stability without causing excessive trauma to the osteotomy site, which may result in bone necrosis. It should also contribute to achieving an effective seal at the implant-abutment junction to preserve the integrity of the marginal soft tissues and reduce the risk of mechanical and biological complications. Furthermore, implant design should support the preservation of marginal bone levels during the initial physiological remodeling phase.
Peak horizontal and vertical loading forces are commonly concentrated at the crestal bone level. Therefore, modifications to the implant collar and thread design have been introduced to improve stress distribution and preserve marginal bone. Microthreads at the implant collar, particularly when combined with an internal conical implant-abutment connection, may contribute to improved biomechanical behavior and better maintenance of peri-implant tissues. Surface modifications have also been introduced to enhance osseointegration. These modifications may be achieved chemically by incorporating inorganic or organic components or physically by altering the surface topography at the micrometer or nanometer level.
A dental implant restoration generally consists of three main components: the implant fixture, an abutment that facilitates the support and retention of the restoration, and the final prosthetic restoration. Provisional restorations play an important role in soft-tissue management around implants. A properly finished and polished provisional crown can help establish a healthy peri-implant soft-tissue contour and provide appropriate support for the gingival margin. The decision regarding the timing and type of provisionalization should consider the expected changes in the facial gingival margin and the need to maintain soft-tissue architecture.
Polyetheretherketone is a synthetic thermoplastic polymer characterized by high mechanical performance and has been used as a biomaterial in various medical applications. A modified form of this material, known as BioHPP, has been specifically optimized for dental applications. It is reinforced with ceramic fillers to improve its mechanical properties and make it suitable for the fabrication of crowns and fixed prostheses.
Monolithic zirconia restorations represent another treatment option. These restorations are milled from solid zirconia blocks and may be individually stained to reproduce the appearance of enamel and gingival tissues. Zirconia provides favorable esthetic properties, particularly because it eliminates the dark cervical line that may occur with metal-based restorations. It is also characterized by high strength, durability, wear resistance, and a low risk of chipping or crack formation.
The differences in the elastic modulus, rigidity, and stress-absorbing capacity of PEEK and zirconia may influence the transmission of occlusal forces to dental implants and the surround
Studienübersicht
Status
Bedingungen
Intervention / Behandlung
Studientyp
Einschreibung (Geschätzt)
Phase
- Unzutreffend
Kontakte und Standorte
Studienkontakt
- Name: kareem mohamed abdel motaleb, master degree
- Telefonnummer: 201005335831
- E-Mail: kareemabdelmotaleb@yahoo.com
Teilnahmekriterien
Zulassungskriterien
Studienberechtigtes Alter
Akzeptiert gesunde Freiwillige
Studienberechtigte Geschlechter
Beschreibung
Inclusion Criteria:
- Age range of the patients from 35-50 years old
- Patients able physically and psychologically implant placement
- patients are medically free.
- Presence of teeth in opposite arch with normal occlusal relation.
- Patient with masticatory forces within the normal range
- Patient with normal muscel tone to avoid bruxer patient and it will be assessed using the electromyograph
- Supra-gingival margin after preparation.
- Patients willing to return for follow-up examinations and evaluation.
- D2 or D3 bone quality will be preferred
Exclusion Criteria:
- Smoking patients.
- Patients with poor oral hygiene and motivation.
- Patients with parafunctional habits.
- D1 and D4 bone quality will be excluded
Studienplan
Wie ist die Studie aufgebaut?
Designdetails
- Hauptzweck: Behandlung
- Zuteilung: Zufällig
- Interventionsmodell: Parallele Zuordnung
- Maskierung: Doppelt
Waffen und Interventionen
Teilnehmergruppe / Arm |
Intervention / Behandlung |
|---|---|
|
Aktiver Komparator: first implant design
first implant design |
PEEK crown zirconia crown |
|
Experimental: second implant design
second implant design |
PEEK crown zirconia crown |
Was misst die Studie?
Primäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
crestal bone loss
Zeitfenster: 1 year
|
Intraoral X-rays will be made using the long-cone parallel technique for the two groups. All radiographs were digitized for evaluation of the bone levels (BL) at different time points. The marginal BL was determined by measuring the distance between the implant shoulder (reference) and the most coronal bone-to implant contact. These measurements were made by two independent examiners mesially and distally of the implants and in 0.1-mm increments |
1 year
|
Sekundäre Ergebnismessungen
Ergebnis Maßnahme |
Maßnahmenbeschreibung |
Zeitfenster |
|---|---|---|
|
gingival index
Zeitfenster: 1 year
|
Gingival index of the two groups will be assessed by the Loe & Silness gingival index as follow: Grade 0: (Normal gingival) Natural coral pink gingival. Grade 1: (Mild inflammation) Slight change in color, slight edema. No bleeding on probing. Grade 2: (Moderate inflammation) Redness, edema and glazing. Bleeding on probing. Grade 3: (Severe inflammation) Marked redness and edema. Tendency to spontaneous bleeding. Ulceration. |
1 year
|
|
probing depth
Zeitfenster: 1 year
|
Probing pocket depth (PPD) for the two groups will be measured from the mucosal margin to the bottom of the probeable pocket in millimeters with a periodontal probe (PCB 12; Hu-Friedy, Leimen, Germany) at four aspects per implant mesial distal buccal lingual The subscales will be summed and an average will be taken. |
1 year
|
Mitarbeiter und Ermittler
Publikationen und hilfreiche Links
Allgemeine Veröffentlichungen
- R.M. Kamal et al. / Al-Azhar Journal of Dentistry 11 (2024) 27e31
Studienaufzeichnungsdaten
Haupttermine studieren
Studienbeginn (Geschätzt)
Primärer Abschluss (Geschätzt)
Studienabschluss (Geschätzt)
Studienanmeldedaten
Zuerst eingereicht
Zuerst eingereicht, das die QC-Kriterien erfüllt hat
Zuerst gepostet (Tatsächlich)
Studienaufzeichnungsaktualisierungen
Letztes Update gepostet (Tatsächlich)
Letztes eingereichtes Update, das die QC-Kriterien erfüllt
Zuletzt verifiziert
Mehr Informationen
Begriffe im Zusammenhang mit dieser Studie
Schlüsselwörter
Andere Studien-ID-Nummern
- serial number of 1006
Plan für individuelle Teilnehmerdaten (IPD)
Planen Sie, individuelle Teilnehmerdaten (IPD) zu teilen?
Arzneimittel- und Geräteinformationen, Studienunterlagen
Studiert ein von der US-amerikanischen FDA reguliertes Arzneimittelprodukt
Studiert ein von der US-amerikanischen FDA reguliertes Geräteprodukt
Produkt, das in den USA hergestellt und aus den USA exportiert wird
Diese Informationen wurden ohne Änderungen direkt von der Website clinicaltrials.gov abgerufen. Wenn Sie Ihre Studiendaten ändern, entfernen oder aktualisieren möchten, wenden Sie sich bitte an register@clinicaltrials.gov. Sobald eine Änderung auf clinicaltrials.gov implementiert wird, wird diese automatisch auch auf unserer Website aktualisiert .