이 페이지는 자동 번역되었으며 번역의 정확성을 보장하지 않습니다. 참조하십시오 영문판 원본 텍스트의 경우.

Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs

2026년 11월 13일 업데이트: kareem mohamed mahmoud abdel motaleb

Appraisal Of The Integrity Of Gingival Tissue And Crestal Bone Of Mandibular Molar Restored With Monolithic Zirconium And PEEK Crowns Supported By Two Different Implant Designs (A Controlled Clinical Trial)

Implant-supported prostheses have become a popular treatment option in clinical dentistry because of their long-term clinical success rates and their proven functional, biological, and mechanical advantages.

Dental implants exhibit biomechanical behavior that differs from that of natural teeth because implants lack periodontal ligaments and are in direct contact with bone. Consequently, the occlusal loads received by the implant are transferred directly to the surrounding bone structure. This relationship affects stress distribution within the implant and the peripheral bone and is considered one of the major factors determining implant success. The transfer of stress or energy between the implant and the surrounding bone is influenced by several factors, including the direction of loading and the design and material characteristics of both the implant and the restorative crown.

Soft-tissue attachment around dental implants resembles that around natural teeth, as it includes junctional epithelium and connective tissue fibers. However, some important differences exist. The connective tissue fibers surrounding implants are oriented parallel rather than perpendicular to the implant surface, and the connective tissue around implants is less vascular than that surrounding natural tooth. The formation and maturation of the peri-implant soft-tissue complex require sufficient healing time. Stable soft-tissue attachment is essential for maintaining osseointegration and protecting the underlying peri-implant bone.

Several major factors influence osseointegration, including implant material, implant design, implant surface finish, bone condition, surgical technique, and implant-loading conditions. The first three factors-implant material, macro-design, and micro-surface characteristics-are directly related to the implant itself and may vary according to the manufacturing process.

The macro-design of dental implants may vary considerably, and several aspects of implant geometry can affect treatment outcomes. The implant design should provide adequate primary stability without causing excessive trauma to the osteotomy site, which may result in bone necrosis. It should also contribute to achieving an effective seal at the implant-abutment junction to preserve the integrity of the marginal soft tissues and reduce the risk of mechanical and biological complications. Furthermore, implant design should support the preservation of marginal bone levels during the initial physiological remodeling phase.

Peak horizontal and vertical loading forces are commonly concentrated at the crestal bone level. Therefore, modifications to the implant collar and thread design have been introduced to improve stress distribution and preserve marginal bone. Microthreads at the implant collar, particularly when combined with an internal conical implant-abutment connection, may contribute to improved biomechanical behavior and better maintenance of peri-implant tissues. Surface modifications have also been introduced to enhance osseointegration. These modifications may be achieved chemically by incorporating inorganic or organic components or physically by altering the surface topography at the micrometer or nanometer level.

A dental implant restoration generally consists of three main components: the implant fixture, an abutment that facilitates the support and retention of the restoration, and the final prosthetic restoration. Provisional restorations play an important role in soft-tissue management around implants. A properly finished and polished provisional crown can help establish a healthy peri-implant soft-tissue contour and provide appropriate support for the gingival margin. The decision regarding the timing and type of provisionalization should consider the expected changes in the facial gingival margin and the need to maintain soft-tissue architecture.

Polyetheretherketone is a synthetic thermoplastic polymer characterized by high mechanical performance and has been used as a biomaterial in various medical applications. A modified form of this material, known as BioHPP, has been specifically optimized for dental applications. It is reinforced with ceramic fillers to improve its mechanical properties and make it suitable for the fabrication of crowns and fixed prostheses.

Monolithic zirconia restorations represent another treatment option. These restorations are milled from solid zirconia blocks and may be individually stained to reproduce the appearance of enamel and gingival tissues. Zirconia provides favorable esthetic properties, particularly because it eliminates the dark cervical line that may occur with metal-based restorations. It is also characterized by high strength, durability, wear resistance, and a low risk of chipping or crack formation.

The differences in the elastic modulus, rigidity, and stress-absorbing capacity of PEEK and zirconia may influence the transmission of occlusal forces to dental implants and the surround

연구 개요

상태

아직 모집하지 않음

연구 유형

중재적

등록 (추정된)

40

단계

  • 해당 없음

연락처 및 위치

이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.

연구 연락처

참여기준

연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.

자격 기준

공부할 수 있는 나이

35년 (성인)

건강한 자원 봉사자를 받아들입니다

예

연구 대상 성별

모두

설명

Inclusion Criteria:

  • Age range of the patients from 35-50 years old
  • Patients able physically and psychologically implant placement
  • patients are medically free.
  • Presence of teeth in opposite arch with normal occlusal relation.
  • Patient with masticatory forces within the normal range
  • Patient with normal muscel tone to avoid bruxer patient and it will be assessed using the electromyograph
  • Supra-gingival margin after preparation.
  • Patients willing to return for follow-up examinations and evaluation.
  • D2 or D3 bone quality will be preferred

Exclusion Criteria:

  • Smoking patients.
  • Patients with poor oral hygiene and motivation.
  • Patients with parafunctional habits.
  • D1 and D4 bone quality will be excluded

공부 계획

이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.

연구는 어떻게 설계됩니까?

디자인 세부사항

  • 주 목적: 치료
  • 할당: 무작위
  • 중재 모델: 병렬 할당
  • 마스킹: 더블

무기와 개입

참가자 그룹 / 팔
개입 / 치료
활성 비교기: first implant design

first implant design

PEEK crown

zirconia crown

실험적: second implant design

second implant design

PEEK crown

zirconia crown

연구는 무엇을 측정합니까?

주요 결과 측정

결과 측정
측정값 설명
기간
crestal bone loss
기간: 1 year

Intraoral X-rays will be made using the long-cone parallel technique for the two groups. All radiographs were digitized for evaluation of the bone levels (BL) at different time points. The marginal BL was determined by measuring the distance between the implant shoulder (reference) and the most coronal bone-to implant contact. These measurements were made by two independent examiners mesially and distally of the implants and in 0.1-mm increments

1 year

2차 결과 측정

결과 측정
측정값 설명
기간
gingival index
기간: 1 year

Gingival index of the two groups will be assessed by the Loe & Silness gingival index as follow:

Grade 0: (Normal gingival) Natural coral pink gingival. Grade 1: (Mild inflammation) Slight change in color, slight edema. No bleeding on probing.

Grade 2: (Moderate inflammation) Redness, edema and glazing. Bleeding on probing.

Grade 3: (Severe inflammation) Marked redness and edema. Tendency to spontaneous bleeding. Ulceration.

1 year
probing depth
기간: 1 year

Probing pocket depth (PPD) for the two groups will be measured from the mucosal margin to the bottom of the probeable pocket in millimeters with a periodontal probe (PCB 12; Hu-Friedy, Leimen, Germany) at four aspects per implant

mesial distal buccal lingual The subscales will be summed and an average will be taken.

1 year

공동 작업자 및 조사자

여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.

간행물 및 유용한 링크

연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.

일반 간행물

  • R.M. Kamal et al. / Al-Azhar Journal of Dentistry 11 (2024) 27e31

연구 기록 날짜

이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.

연구 주요 날짜

연구 시작 (추정된)

2026년 11월 1일

기본 완료 (추정된)

2027년 9월 1일

연구 완료 (추정된)

2027년 9월 1일

연구 등록 날짜

최초 제출

2026년 11월 7일

QC 기준을 충족하는 최초 제출

2026년 11월 13일

처음 게시됨 (실제)

2026년 11월 17일

연구 기록 업데이트

마지막 업데이트 게시됨 (실제)

2026년 11월 17일

QC 기준을 충족하는 마지막 업데이트 제출

2026년 11월 13일

마지막으로 확인됨

2026년 11월 1일

추가 정보

이 연구와 관련된 용어

기타 연구 ID 번호

  • serial number of 1006

개별 참가자 데이터(IPD) 계획

개별 참가자 데이터(IPD)를 공유할 계획입니까?

미정

약물 및 장치 정보, 연구 문서

미국 FDA 규제 의약품 연구

아니

미국 FDA 규제 기기 제품 연구

아니

미국에서 제조되어 미국에서 수출되는 제품

아니

이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .