Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction (FIXAR)
Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction: A Prospective Randomised Controlled Trial
The surgical management of distal radius fractures via open reduction and internal fixation (ORIF) remains the gold standard for restoring wrist function. However, the procedure is traditionally characterized by repetitive workflow interruptions of the removal of metallic retractors to avoid radiological artifacts and the ergonomic strain of the "head-turn" required to view distant fluoroscopy monitors.
The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. This device was developed at the University of Hong Kong and invention is held by HKU Versitech Limited.
This study aims to definitively evaluate the gadget-optimized distal radius fixation surgery with the RRRR and head-mounted Augmented Reality glasses display to optimize the surgical workflow. This trial will evaluate whether this system provides a more efficient alternative to conventional monitor-based fluoroscopy in modern orthopedic practice.
調査の概要
状態
条件
研究の種類
入学 (推定)
段階
- 適用できない
連絡先と場所
研究連絡先
- 名前:Christian Prof. Fang
- 電話番号:+852 22554581
- メール:cfang@hku.hk
研究場所
-
-
-
Hong Kong、香港
- Queen Mary Hospital, The University of Hong Kong
-
コンタクト:
- Christian Prof. Fang
- 電話番号:+852 22554581
- メール:cfang@hku.hk
-
-
参加基準
適格基準
就学可能な年齢
健康ボランティアの受け入れ
受講資格のある性別
説明
Inclusion Criteria:
- Adults (18-85 years)
- Distal radial fractures requiring Open Reduction and Internal Fixation.
- Patients that would be suitable for the volar approach.
Exclusion Criteria:
- Open fractures
- Active infection
- Polytrauma patients where the wrist is not the primary focus.
研究計画
研究はどのように設計されていますか?
デザインの詳細
- 主な目的:処理
- 割り当て:ランダム化
- 介入モデル:並列代入
- マスキング:独身
武器と介入
参加者グループ / アーム |
介入・治療 |
|---|---|
|
実験的:Radius Radiolucent Ring Retractor and the Augmented Reality Glasses
The surgery will be completed with the combination of Radius Radiolucent Ring Retractor (RRRR) and Augmented Reality Glasses. The RRRR is a 3D-printed surgical tool designed for hands-free retraction in arm and wrist surgeries. The Augmented Reality Glasses for surgeons designed specifically for surgeons can display real-time X-ray images directly in the doctor's field of vision, allowing the doctor to focus on the wrist throughout the procedure without having to turn their head to look at the X-ray screen. |
The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. Augmented Reality of C-Arm intraoperative fluoroscopic imaging integration with a head mount-display (HMD). |
|
アクティブコンパレータ:Metal tools and standard X-ray monitor
Traditional method with metal retractors and standard X-ray monitor. |
Manual traditional metal retractor used by surgeons and assistants. Standard X-ray monitor that displays fluoroscopy images during the operation. |
この研究は何を測定していますか?
主要な結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Total Fluoroscopy Time
時間枠:Intra-operative
|
The total duration, measured in minutes or seconds, that the X-ray beam is actively turned on during a fluoroscopic procedure during the operation. |
Intra-operative
|
|
Functional Assessment measured by QuickDASH Score
時間枠:At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
The QuickDASH score is a validated, internationally recognized tool to assess functional outcomes of patients of the upper arm, especially in long term recovery assessments. The survey will assess the control group against intervention group in return to daily activities, assessment of overall upper limb function, symptoms, and quality of life. |
At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
二次結果の測定
結果測定 |
メジャーの説明 |
時間枠 |
|---|---|---|
|
Rating of placement of implant using 25 point Surgeon-Reported Outcome Measures
時間枠:Immediately after operation
|
The qualitative assessment of 1 to 5 of the placement of implant rated by the surgeon. |
Immediately after operation
|
|
Rating of ergonomics and visualisation of plate position using 25 point Surgeon-Reported Outcome Measures
時間枠:Immediately after operation
|
The qualitative assessment of 1 to 5 of the ergonomics and visualisation of plate position rated by the surgeon. |
Immediately after operation
|
|
Rating of retraction during fluoroscopy using 25 point Surgeon-Reported Outcome Measures
時間枠:Immediately after operation
|
The qualitative assessment of 1 to 5 of the retraction during fluoroscopy rated by the surgeon. |
Immediately after operation
|
|
Rating of fracture reduction using 25 point Surgeon-Reported Outcome Measures
時間枠:Immediately after operation
|
The qualitative assessment of 1 to 5 of the quality of fracture reduction rated by the surgeon. |
Immediately after operation
|
|
Rating of overall assistants' efforts using 25 point Surgeon-Reported Outcome Measures
時間枠:Immediately after operation
|
The qualitative assessment of 1 to 5 of the quality of overall assistants' efforts rated by the surgeon. |
Immediately after operation
|
|
Number of surgical assistants
時間枠:Intra-operative
|
The maximum number of surgical assistants required for retraction tasks at any single point during the surgery. |
Intra-operative
|
|
Number of times retractors were removed and replaced
時間枠:Intra-operative
|
The number of times the whole RRRR or the metal retractor is lifted out of the incision site, then putting it back count as 1. |
Intra-operative
|
|
Number of times the retractor was loosened from the surgical site
時間枠:Intra-operative
|
The number of times the traditional retractor or RRRR is not adequately retracting the surgical wound and providing a clear view of the fracture site, |
Intra-operative
|
|
Number of readjustments for fracture reduction
時間枠:Intra-operative
|
The number of times that a fracture reduction is changed during the operation. |
Intra-operative
|
|
Number of attempts for repositioning Kirschner wire
時間枠:Intra-operative
|
The numbers of times the Kirschner wire is removed from the incision site and then putting it back count as 1. |
Intra-operative
|
|
Maximum number of Kirschner wire used to maintain positioning and/or reduction
時間枠:Intra-operative
|
The maximum number of Kirschner wires at any time point that are used to maintain implant positioning and/or fracture reduction. |
Intra-operative
|
|
Number of repositioning of plates
時間枠:Intra-operative
|
The number of times the implant plate is moved and repositioned is recorded as 1. |
Intra-operative
|
|
Number of repositioning of screws
時間枠:Intra-operative
|
The number of times the screw is removed from the incision site and repositioned is recorded as 1. |
Intra-operative
|
|
Total number of screws used in the operation
時間枠:Intra-operative
|
The total number of screws that are used in the operation, including those that are implanted or wasted. |
Intra-operative
|
|
Number of head turns to assess x-ray images
時間枠:Intra-operative
|
The number of times the primary surgeon looks at the fluoroscopy monitor during fracture reduction. |
Intra-operative
|
|
Number of times the eyepiece focus is lost
時間枠:Intra-operative
|
The number of times the AR HMD eyepiece is out of focus is recorded as 1. |
Intra-operative
|
|
Duration of surgery
時間枠:Intra-operative
|
Defined from the time difference of the incision start time and the completion time of final suturing. |
Intra-operative
|
|
Incision Length in mm
時間枠:Intra-operative
|
Defined as the length in millimeters of the incision cut in the surgery. |
Intra-operative
|
|
Radial Inclination in degrees
時間枠:At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
Measurement of the coronal-plane slope of the distal radius articular surface, measured in pre-operative and post-operative wrist x-ray. |
At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
|
Radial Height in millimeters
時間枠:At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
Measurement of the axial distance between perpendicular lines at the radial styloid and ulnar border, quantifying fracture-induced radial shortening, measured in pre-operative and post-operative wrist x-ray. |
At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
|
Volar / Dorsal Angulation in degrees
時間枠:At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
Measurement of the tilt of the distal articular surface relative to the shaft, measured in pre-operative and post-operative wrist x-ray. |
At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
|
Articular Step-off in millimeters
時間枠:At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
Measurement of the vertical incongruity along the subchondral surface, measured in pre-operative and post-operative wrist x-ray. |
At post-op, 3 weeks, 6 weeks , 3 months and 6 months
|
協力者と研究者
捜査官
- 主任研究者:Christian Prof. Fang、Dept of Orthopaedics and Traumatology, Queen Mary Hospital
出版物と役立つリンク
一般刊行物
- Fang C, Fang E, Yee DK, Kwan K, Leung G, Leung F. A comparison of six outcome measures across the recovery period after distal radius fixation-Which to use and when? J Orthop Surg (Hong Kong). 2021 Jan-Apr;29(1):2309499020971866. doi: 10.1177/2309499020971866.
- Al-Dahan T, Virani S, Asardag AN, Seoudi N, Izedonmwen I, Sherpa N, Murad MA, Ekungba-Adewole M, Seidahmed S, Gurung Y. Fluoroscopy Exposure During Distal Radius Fracture Fixation: An Audit of Current Practice. Cureus. 2025 Dec 20;17(12):e99719. doi: 10.7759/cureus.99719. eCollection 2025 Dec.
- von der Heide AM, Fallavollita P, Wang L, Sandner P, Navab N, Weidert S, Euler E. Camera-augmented mobile C-arm (CamC): A feasibility study of augmented reality imaging in the operating room. Int J Med Robot. 2018 Apr;14(2). doi: 10.1002/rcs.1885. Epub 2017 Dec 21.
- Chimenti PC, Mitten DJ. Google Glass as an Alternative to Standard Fluoroscopic Visualization for Percutaneous Fixation of Hand Fractures: A Pilot Study. Plast Reconstr Surg. 2015 Aug;136(2):328-330. doi: 10.1097/PRS.0000000000001453.
- Ortega G, Wolff A, Baumgaertner M, Kendoff D. Usefulness of a head mounted monitor device for viewing intraoperative fluoroscopy during orthopaedic procedures. Arch Orthop Trauma Surg. 2008 Oct;128(10):1123-6. doi: 10.1007/s00402-007-0500-y. Epub 2007 Nov 14.
- Laverdiere C, Corban J, Khoury J, Ge SM, Schupbach J, Harvey EJ, Reindl R, Martineau PA. Augmented reality in orthopaedics: a systematic review and a window on future possibilities. Bone Joint J. 2019 Dec;101-B(12):1479-1488. doi: 10.1302/0301-620X.101B12.BJJ-2019-0315.R1.
- Jud L, Fotouhi J, Andronic O, Aichmair A, Osgood G, Navab N, Farshad M. Applicability of augmented reality in orthopedic surgery - A systematic review. BMC Musculoskelet Disord. 2020 Feb 15;21(1):103. doi: 10.1186/s12891-020-3110-2.
- Shi Y, Wu X, Paydarfar JA, Halter RJ. An Imaging-Compatible Oral Retractor System for Transoral Robotic Surgery. Ann Biomed Eng. 2024 Sep;52(9):2473-2484. doi: 10.1007/s10439-024-03536-7. Epub 2024 May 25.
研究記録日
主要日程の研究
研究開始 (推定)
一次修了 (推定)
研究の完了 (推定)
試験登録日
最初に提出
QC基準を満たした最初の提出物
最初の投稿 (実際)
学習記録の更新
投稿された最後の更新 (実際)
QC基準を満たした最後の更新が送信されました
最終確認日
詳しくは
本研究に関する用語
個々の参加者データ (IPD) の計画
個々の参加者データ (IPD) を共有する予定はありますか?
IPD プランの説明
Anonymized dataset to be included as supplementary data in final publication
IPD 共有時間枠
Within 1 year of study completion
IPD 共有アクセス基準
Additional information available upon reasonable request of principal investigator
IPD 共有サポート情報タイプ
- STUDY_PROTOCOL
- SAP
- ICF
- CSR
医薬品およびデバイス情報、研究文書
米国FDA規制医薬品の研究
米国FDA規制機器製品の研究
この情報は、Web サイト clinicaltrials.gov から変更なしで直接取得したものです。研究の詳細を変更、削除、または更新するリクエストがある場合は、register@clinicaltrials.gov。 までご連絡ください。 clinicaltrials.gov に変更が加えられるとすぐに、ウェブサイトでも自動的に更新されます。