Denne side blev automatisk oversat, og nøjagtigheden af ​​oversættelsen er ikke garanteret. Der henvises til engelsk version for en kildetekst.

Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction (FIXAR)

13. november 2026 opdateret af: Prof. Christian Xinshuo Fang, The University of Hong Kong

Fracture Internal X-fixation With Augmented Reality and Radiolucent Ring Retraction: A Prospective Randomised Controlled Trial

The surgical management of distal radius fractures via open reduction and internal fixation (ORIF) remains the gold standard for restoring wrist function. However, the procedure is traditionally characterized by repetitive workflow interruptions of the removal of metallic retractors to avoid radiological artifacts and the ergonomic strain of the "head-turn" required to view distant fluoroscopy monitors.

The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries. This device was developed at the University of Hong Kong and invention is held by HKU Versitech Limited.

This study aims to definitively evaluate the gadget-optimized distal radius fixation surgery with the RRRR and head-mounted Augmented Reality glasses display to optimize the surgical workflow. This trial will evaluate whether this system provides a more efficient alternative to conventional monitor-based fluoroscopy in modern orthopedic practice.

Studieoversigt

Undersøgelsestype

Interventionel

Tilmelding (Anslået)

94

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiekontakt

  • Navn: Christian Prof. Fang
  • Telefonnummer: +852 22554581
  • E-mail: cfang@hku.hk

Studiesteder

      • Hong Kong, Hong Kong
        • Queen Mary Hospital, The University of Hong Kong
        • Kontakt:
          • Christian Prof. Fang
          • Telefonnummer: +852 22554581
          • E-mail: cfang@hku.hk

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år til 85 år (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • Adults (18-85 years)
  • Distal radial fractures requiring Open Reduction and Internal Fixation.
  • Patients that would be suitable for the volar approach.

Exclusion Criteria:

  • Open fractures
  • Active infection
  • Polytrauma patients where the wrist is not the primary focus.

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Behandling
  • Tildeling: Randomiseret
  • Interventionel model: Parallel tildeling
  • Maskning: Enkelt

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Eksperimentel: Radius Radiolucent Ring Retractor and the Augmented Reality Glasses

The surgery will be completed with the combination of Radius Radiolucent Ring Retractor (RRRR) and Augmented Reality Glasses.

The RRRR is a 3D-printed surgical tool designed for hands-free retraction in arm and wrist surgeries.

The Augmented Reality Glasses for surgeons designed specifically for surgeons can display real-time X-ray images directly in the doctor's field of vision, allowing the doctor to focus on the wrist throughout the procedure without having to turn their head to look at the X-ray screen.

The Radius Radiolucent Ring Retractor (RRRR) is a single-use, 3D-printed nylon surgical device designed for hands-free retraction in arm and wrist surgeries.

Augmented Reality of C-Arm intraoperative fluoroscopic imaging integration with a head mount-display (HMD).

Aktiv komparator: Metal tools and standard X-ray monitor

Traditional method with metal retractors and standard X-ray monitor.

Manual traditional metal retractor used by surgeons and assistants.

Standard X-ray monitor that displays fluoroscopy images during the operation.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Total Fluoroscopy Time
Tidsramme: Intra-operative

The total duration, measured in minutes or seconds, that the X-ray beam is actively turned on during a fluoroscopic procedure during the operation.

Intra-operative
Functional Assessment measured by QuickDASH Score
Tidsramme: At post-op, 3 weeks, 6 weeks , 3 months and 6 months

The QuickDASH score is a validated, internationally recognized tool to assess functional outcomes of patients of the upper arm, especially in long term recovery assessments. The survey will assess the control group against intervention group in return to daily activities, assessment of overall upper limb function, symptoms, and quality of life.

At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Sekundære resultatmål

Resultatmål
Foranstaltningsbeskrivelse
Tidsramme
Rating of placement of implant using 25 point Surgeon-Reported Outcome Measures
Tidsramme: Immediately after operation

The qualitative assessment of 1 to 5 of the placement of implant rated by the surgeon.

Immediately after operation
Rating of ergonomics and visualisation of plate position using 25 point Surgeon-Reported Outcome Measures
Tidsramme: Immediately after operation

The qualitative assessment of 1 to 5 of the ergonomics and visualisation of plate position rated by the surgeon.

Immediately after operation
Rating of retraction during fluoroscopy using 25 point Surgeon-Reported Outcome Measures
Tidsramme: Immediately after operation

The qualitative assessment of 1 to 5 of the retraction during fluoroscopy rated by the surgeon.

Immediately after operation
Rating of fracture reduction using 25 point Surgeon-Reported Outcome Measures
Tidsramme: Immediately after operation

The qualitative assessment of 1 to 5 of the quality of fracture reduction rated by the surgeon.

Immediately after operation
Rating of overall assistants' efforts using 25 point Surgeon-Reported Outcome Measures
Tidsramme: Immediately after operation

The qualitative assessment of 1 to 5 of the quality of overall assistants' efforts rated by the surgeon.

Immediately after operation
Number of surgical assistants
Tidsramme: Intra-operative

The maximum number of surgical assistants required for retraction tasks at any single point during the surgery.

Intra-operative
Number of times retractors were removed and replaced
Tidsramme: Intra-operative

The number of times the whole RRRR or the metal retractor is lifted out of the incision site, then putting it back count as 1.

Intra-operative
Number of times the retractor was loosened from the surgical site
Tidsramme: Intra-operative

The number of times the traditional retractor or RRRR is not adequately retracting the surgical wound and providing a clear view of the fracture site,

Intra-operative
Number of readjustments for fracture reduction
Tidsramme: Intra-operative

The number of times that a fracture reduction is changed during the operation.

Intra-operative
Number of attempts for repositioning Kirschner wire
Tidsramme: Intra-operative

The numbers of times the Kirschner wire is removed from the incision site and then putting it back count as 1.

Intra-operative
Maximum number of Kirschner wire used to maintain positioning and/or reduction
Tidsramme: Intra-operative

The maximum number of Kirschner wires at any time point that are used to maintain implant positioning and/or fracture reduction.

Intra-operative
Number of repositioning of plates
Tidsramme: Intra-operative

The number of times the implant plate is moved and repositioned is recorded as 1.

Intra-operative
Number of repositioning of screws
Tidsramme: Intra-operative

The number of times the screw is removed from the incision site and repositioned is recorded as 1.

Intra-operative
Total number of screws used in the operation
Tidsramme: Intra-operative

The total number of screws that are used in the operation, including those that are implanted or wasted.

Intra-operative
Number of head turns to assess x-ray images
Tidsramme: Intra-operative

The number of times the primary surgeon looks at the fluoroscopy monitor during fracture reduction.

Intra-operative
Number of times the eyepiece focus is lost
Tidsramme: Intra-operative

The number of times the AR HMD eyepiece is out of focus is recorded as 1.

Intra-operative
Duration of surgery
Tidsramme: Intra-operative

Defined from the time difference of the incision start time and the completion time of final suturing.

Intra-operative
Incision Length in mm
Tidsramme: Intra-operative

Defined as the length in millimeters of the incision cut in the surgery.

Intra-operative
Radial Inclination in degrees
Tidsramme: At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Measurement of the coronal-plane slope of the distal radius articular surface, measured in pre-operative and post-operative wrist x-ray.

At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Radial Height in millimeters
Tidsramme: At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Measurement of the axial distance between perpendicular lines at the radial styloid and ulnar border, quantifying fracture-induced radial shortening, measured in pre-operative and post-operative wrist x-ray.

At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Volar / Dorsal Angulation in degrees
Tidsramme: At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Measurement of the tilt of the distal articular surface relative to the shaft, measured in pre-operative and post-operative wrist x-ray.

At post-op, 3 weeks, 6 weeks , 3 months and 6 months
Articular Step-off in millimeters
Tidsramme: At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Measurement of the vertical incongruity along the subchondral surface, measured in pre-operative and post-operative wrist x-ray.

At post-op, 3 weeks, 6 weeks , 3 months and 6 months

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Christian Prof. Fang, Dept of Orthopaedics and Traumatology, Queen Mary Hospital

Publikationer og nyttige links

Den person, der er ansvarlig for at indtaste oplysninger om undersøgelsen, leverer frivilligt disse publikationer. Disse kan handle om alt relateret til undersøgelsen.

Generelle publikationer

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart (Anslået)

1. december 2026

Primær færdiggørelse (Anslået)

31. marts 2028

Studieafslutning (Anslået)

31. marts 2028

Datoer for studieregistrering

Først indsendt

26. oktober 2026

Først indsendt, der opfyldte QC-kriterier

13. november 2026

Først opslået (Faktiske)

17. november 2026

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

17. november 2026

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

13. november 2026

Sidst verificeret

1. oktober 2026

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • UW 26-371

Plan for individuelle deltagerdata (IPD)

Planlægger du at dele individuelle deltagerdata (IPD)?

JA

IPD-planbeskrivelse

Anonymized dataset to be included as supplementary data in final publication

IPD-delingstidsramme

Within 1 year of study completion

IPD-delingsadgangskriterier

Additional information available upon reasonable request of principal investigator

IPD-deling Understøttende informationstype

  • STUDY_PROTOCOL
  • SAP
  • ICF
  • CSR

Lægemiddel- og udstyrsoplysninger, undersøgelsesdokumenter

Studerer et amerikansk FDA-reguleret lægemiddelprodukt

Ingen

Studerer et amerikansk FDA-reguleret enhedsprodukt

Ingen

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Abonner