Assessing Continuous Glucose Monitors in Healthy Children
DirecNet Pilot Study to Assess the Accuracy of Continuous Glucose Monitors in Normal Children
연구 개요
상세 설명
The characterization of glucose levels in healthy children during day and nighttime is critical to the interpretation of glucose levels in diseases such as diabetes. This study was conducted by the DirecNet Study Group to determine whether two FDA-approved continuous glucose monitors are sufficiently accurate.
The study was conducted at five clinical centers and enrolled approximately 20 healthy children (ages 7 to 17 years old) who did not have Type 1 or Type 2 diabetes nor a history of the disease in their immediate families. Each participant was hospitalized for approximately 26 hours to assess the accuracy of the continuous glucose monitors compared with serum glucose determinations.
연구 유형
등록
단계
- 4단계
연락처 및 위치
연구 장소
-
-
California
-
Stanford, California, 미국, 94305-5208
- Division of Pediatric Endocrinology and Diabetes, Stanford University
-
-
Colorado
-
Denver, Colorado, 미국, 80262
- Barbara Davis Center for Childhood Diabetes, University of Colorado
-
-
Connecticut
-
New Haven, Connecticut, 미국, 06519
- Department of Pediatrics, Yale University School of Medicine
-
-
Florida
-
Jacksonville,, Florida, 미국, 32207
- Nemours Children's Clinic
-
Tampa, Florida, 미국, 33647
- Jaeb Center for Health Research
-
-
Iowa
-
Iowa City, Iowa, 미국, 52242
- Department of Pediatrics, University of Iowa Carver College of Medicine
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria
- Weight >= 16.0 kg (35 lbs)
- Body mass index between the 10th to 90th percentile for age and sex
- HbA1c within normal limits
- Hematocrit within normal limits
Exclusion Criteria
- History of diabetes
- History of positive islet cell antibody testing
- Family history of Type 1 or Type 2 diabetes in a sibling or parent
- Medication use of any type in the 7 days prior to study entry
- Skin abnormalities contraindicating device use
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 치료
- 할당: 무작위화되지 않음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
|---|
|
Accuracy of the GlucoWatch G2 Biographer and CGMS sensors
|
공동 작업자 및 조사자
간행물 및 유용한 링크
일반 간행물
- Mauras N, Beck RW, Ruedy KJ, Kollman C, Tamborlane WV, Chase HP, Buckingham BA, Tsalikian E, Weinzimer S, Booth AD, Xing D; Diabetes Research in Children Network (DirecNet) Accuracy Study. Lack of accuracy of continuous glucose sensors in healthy, nondiabetic children: results of the Diabetes Research in Children Network (DirecNet) accuracy study. J Pediatr. 2004 Jun;144(6):770-5. doi: 10.1016/j.jpeds.2004.03.042.
- Mauras N, Beck R, Ruedy K, Booth A, Weinzimer S, and the Diabetes Research in Children Network (DirecNet) Study Group. The Physiological Variations of Plasma Glucose Concentrations in Healthy, Non-Diabetic Children: Use of Continuous Glucose Sensors. Pediatr Res 2003 Apr;53(4Pt 2):1A-669A
- Weinzimer S, Beck R, Ruedy K, Booth A, Boland E, and the Diabetes Research in Children Network (DirecNet) Study Group. Mealtime Glycemic Excursions in Pediatric Subjects with Type 1 Diabetes Mellitus (T1DM): The DirecNet Experience.Pediatr Res 2003 Apr;53(4Pt2):1A-669A
- Tsalikian E, Beck R, Ruedy K, Booth A, Tansey M, and the Diabetes Research in Children Network (DirecNet) Study Group. Glycemic Pattern of Insulin Induced Hypoglycemia in Pediatric Subjects with Type 1 Diabetes Mellitus (T1DM): The DirecNet Experience. Pediatr Res 2003 Apr;53(4Pt2):1A-669A
- Buckingham B, Beck R, Tamborlane W, Ruedy K, Boland E, Chase P, Wysocki T, Tsalikian E, Wilson D, Mauras N, Weinzimer D, Tansey M, Fiallo-Scharer R, Booth A, Kollman C, and the Diabetes Research In Children Network (DirecNet) Study Group. Diabetes Research in Children Network (DirecNet) Accuracy Study of the Continuous Glucose Monitoring System (CGMS) and GlucoWatch® G2™ Biographer (GWB) in Children with Type 1 Diabetes-A CRC-based Study. Diabetes 2003 Jun;52 Suppl 1:A36.
- Wilson D, Buckingham B, Beck R, Ruedy K, Kollman C, Tsalikian E, Wysocki T, Weinzimer S, Chase P, and the Diabetes Research in Children Network (DirecNet) Study Group. A 5-center CRC-based Study of the Accuracy of the GlucoWatch®G2™ Biographer in Children and Adolescents with Type 1 Diabetes. Diabetes 2003 Jun;52 Suppl 1:A101.
- Boland E, Weinzimer S, Beck R, Ruedy K, Kollman C, Buckingham B, Chase P, Tansey M, Mauras N, and the Diabetes Research In Children Network (DirecNet) Study Group. Performance of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in Children with T1DM in the DirecNet Accuracy Study. Diabetes 2003 Jun;52 Suppl 1:A90.
- Fiallo-Scharer R, Chase P, Beck R, Ruedy K, Booth A, Wysocki T, Boland E, Buckingham B, Tsalikian E, and the Diabetes Research In Children Network (DirecNet) Study Group. Performance of the One Touch Ultra at Different Glucose Levels in Three Age Groups of Children with T1DM in the CRC-DirecNet Accuracy Study. Diabetes 2003 Jun;52 Suppl 1:A562.
연구 기록 날짜
연구 주요 날짜
연구 시작
연구 완료
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (추정)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 연구와 관련된 용어
키워드
기타 연구 ID 번호
- DirecNet 002
- HD041890
- HD041919-01
- HD041908-01
- HD041906-01
- HD041918-01
- HD041915
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .