Cette page a été traduite automatiquement et l'exactitude de la traduction n'est pas garantie. Veuillez vous référer au version anglaise pour un texte source.

Assessing Continuous Glucose Monitors in Healthy Children

2 septembre 2016 mis à jour par: Jaeb Center for Health Research

DirecNet Pilot Study to Assess the Accuracy of Continuous Glucose Monitors in Normal Children

Continuous glucose monitors may be useful in the treatment of children with Type 1 diabetes mellitus. The purpose of this study was to determine whether two FDA-approved continuous glucose monitors, the Continuous Glucose Monitoring System (CGMS) and the GlucoWatch G2TM Biographer (GW2B), are sufficiently accurate to use in future studies to characterize glucose levels in children.

Aperçu de l'étude

Description détaillée

The characterization of glucose levels in healthy children during day and nighttime is critical to the interpretation of glucose levels in diseases such as diabetes. This study was conducted by the DirecNet Study Group to determine whether two FDA-approved continuous glucose monitors are sufficiently accurate.

The study was conducted at five clinical centers and enrolled approximately 20 healthy children (ages 7 to 17 years old) who did not have Type 1 or Type 2 diabetes nor a history of the disease in their immediate families. Each participant was hospitalized for approximately 26 hours to assess the accuracy of the continuous glucose monitors compared with serum glucose determinations.

Type d'étude

Interventionnel

Inscription

20

Phase

  • Phase 4

Contacts et emplacements

Cette section fournit les coordonnées de ceux qui mènent l'étude et des informations sur le lieu où cette étude est menée.

Lieux d'étude

    • California
      • Stanford, California, États-Unis, 94305-5208
        • Division of Pediatric Endocrinology and Diabetes, Stanford University
    • Colorado
      • Denver, Colorado, États-Unis, 80262
        • Barbara Davis Center for Childhood Diabetes, University of Colorado
    • Connecticut
      • New Haven, Connecticut, États-Unis, 06519
        • Department of Pediatrics, Yale University School of Medicine
    • Florida
      • Jacksonville,, Florida, États-Unis, 32207
        • Nemours Children's Clinic
      • Tampa, Florida, États-Unis, 33647
        • Jaeb Center for Health Research
    • Iowa
      • Iowa City, Iowa, États-Unis, 52242
        • Department of Pediatrics, University of Iowa Carver College of Medicine

Critères de participation

Les chercheurs recherchent des personnes qui correspondent à une certaine description, appelée critères d'éligibilité. Certains exemples de ces critères sont l'état de santé général d'une personne ou des traitements antérieurs.

Critère d'éligibilité

Âges éligibles pour étudier

7 ans à 17 ans (Enfant)

Accepte les volontaires sains

Oui

Sexes éligibles pour l'étude

Tout

La description

Inclusion Criteria

  • Weight >= 16.0 kg (35 lbs)
  • Body mass index between the 10th to 90th percentile for age and sex
  • HbA1c within normal limits
  • Hematocrit within normal limits

Exclusion Criteria

  • History of diabetes
  • History of positive islet cell antibody testing
  • Family history of Type 1 or Type 2 diabetes in a sibling or parent
  • Medication use of any type in the 7 days prior to study entry
  • Skin abnormalities contraindicating device use

Plan d'étude

Cette section fournit des détails sur le plan d'étude, y compris la façon dont l'étude est conçue et ce que l'étude mesure.

Comment l'étude est-elle conçue ?

Détails de conception

  • Objectif principal: Traitement
  • Répartition: Non randomisé
  • Modèle interventionnel: Affectation à un seul groupe
  • Masquage: Aucun (étiquette ouverte)

Que mesure l'étude ?

Principaux critères de jugement

Mesure des résultats
Accuracy of the GlucoWatch G2 Biographer and CGMS sensors

Collaborateurs et enquêteurs

C'est ici que vous trouverez les personnes et les organisations impliquées dans cette étude.

Publications et liens utiles

La personne responsable de la saisie des informations sur l'étude fournit volontairement ces publications. Il peut s'agir de tout ce qui concerne l'étude.

Publications générales

  • Mauras N, Beck RW, Ruedy KJ, Kollman C, Tamborlane WV, Chase HP, Buckingham BA, Tsalikian E, Weinzimer S, Booth AD, Xing D; Diabetes Research in Children Network (DirecNet) Accuracy Study. Lack of accuracy of continuous glucose sensors in healthy, nondiabetic children: results of the Diabetes Research in Children Network (DirecNet) accuracy study. J Pediatr. 2004 Jun;144(6):770-5. doi: 10.1016/j.jpeds.2004.03.042.
  • Mauras N, Beck R, Ruedy K, Booth A, Weinzimer S, and the Diabetes Research in Children Network (DirecNet) Study Group. The Physiological Variations of Plasma Glucose Concentrations in Healthy, Non-Diabetic Children: Use of Continuous Glucose Sensors. Pediatr Res 2003 Apr;53(4Pt 2):1A-669A
  • Weinzimer S, Beck R, Ruedy K, Booth A, Boland E, and the Diabetes Research in Children Network (DirecNet) Study Group. Mealtime Glycemic Excursions in Pediatric Subjects with Type 1 Diabetes Mellitus (T1DM): The DirecNet Experience.Pediatr Res 2003 Apr;53(4Pt2):1A-669A
  • Tsalikian E, Beck R, Ruedy K, Booth A, Tansey M, and the Diabetes Research in Children Network (DirecNet) Study Group. Glycemic Pattern of Insulin Induced Hypoglycemia in Pediatric Subjects with Type 1 Diabetes Mellitus (T1DM): The DirecNet Experience. Pediatr Res 2003 Apr;53(4Pt2):1A-669A
  • Buckingham B, Beck R, Tamborlane W, Ruedy K, Boland E, Chase P, Wysocki T, Tsalikian E, Wilson D, Mauras N, Weinzimer D, Tansey M, Fiallo-Scharer R, Booth A, Kollman C, and the Diabetes Research In Children Network (DirecNet) Study Group. Diabetes Research in Children Network (DirecNet) Accuracy Study of the Continuous Glucose Monitoring System (CGMS) and GlucoWatch® G2™ Biographer (GWB) in Children with Type 1 Diabetes-A CRC-based Study. Diabetes 2003 Jun;52 Suppl 1:A36.
  • Wilson D, Buckingham B, Beck R, Ruedy K, Kollman C, Tsalikian E, Wysocki T, Weinzimer S, Chase P, and the Diabetes Research in Children Network (DirecNet) Study Group. A 5-center CRC-based Study of the Accuracy of the GlucoWatch®G2™ Biographer in Children and Adolescents with Type 1 Diabetes. Diabetes 2003 Jun;52 Suppl 1:A101.
  • Boland E, Weinzimer S, Beck R, Ruedy K, Kollman C, Buckingham B, Chase P, Tansey M, Mauras N, and the Diabetes Research In Children Network (DirecNet) Study Group. Performance of the Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) in Children with T1DM in the DirecNet Accuracy Study. Diabetes 2003 Jun;52 Suppl 1:A90.
  • Fiallo-Scharer R, Chase P, Beck R, Ruedy K, Booth A, Wysocki T, Boland E, Buckingham B, Tsalikian E, and the Diabetes Research In Children Network (DirecNet) Study Group. Performance of the One Touch Ultra at Different Glucose Levels in Three Age Groups of Children with T1DM in the CRC-DirecNet Accuracy Study. Diabetes 2003 Jun;52 Suppl 1:A562.

Dates d'enregistrement des études

Ces dates suivent la progression des dossiers d'étude et des soumissions de résultats sommaires à ClinicalTrials.gov. Les dossiers d'étude et les résultats rapportés sont examinés par la Bibliothèque nationale de médecine (NLM) pour s'assurer qu'ils répondent à des normes de contrôle de qualité spécifiques avant d'être publiés sur le site Web public.

Dates principales de l'étude

Début de l'étude

1 août 2002

Achèvement de l'étude

1 novembre 2002

Dates d'inscription aux études

Première soumission

29 septembre 2003

Première soumission répondant aux critères de contrôle qualité

29 septembre 2003

Première publication (Estimation)

30 septembre 2003

Mises à jour des dossiers d'étude

Dernière mise à jour publiée (Estimation)

5 septembre 2016

Dernière mise à jour soumise répondant aux critères de contrôle qualité

2 septembre 2016

Dernière vérification

1 septembre 2016

Plus d'information

Termes liés à cette étude

Autres numéros d'identification d'étude

  • DirecNet 002
  • HD041890
  • HD041919-01
  • HD041908-01
  • HD041906-01
  • HD041918-01
  • HD041915

Ces informations ont été extraites directement du site Web clinicaltrials.gov sans aucune modification. Si vous avez des demandes de modification, de suppression ou de mise à jour des détails de votre étude, veuillez contacter register@clinicaltrials.gov. Dès qu'un changement est mis en œuvre sur clinicaltrials.gov, il sera également mis à jour automatiquement sur notre site Web .