- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT01230684
Contrast Enhanced Ultrasound vs. Computed Tomographic Angiography in the Detection of Endoleaks Following AAA Repair
Comparison of Contrast Enhanced Ultrasound and the Gold Standard Computed Tomographic Angiography in Detection of Endoleak Following Endovascular Abdominal Aortic Aneurysm Repair.
연구 개요
상태
상세 설명
Background:
Abdominal aortic aneurysms (AAAs) continue to be a leading cause of death in older age groups. In the 60-85 year-old population, AAA represents the 14th-leading cause of death. Federal funding through Medicare has been allocated for early detection using abdominal ultrasound screening programs. Despite these more aggressive screening programs and concerted efforts by surgeons for timely repair, the incidence of ruptured AAA has continued to increase.
Endovascular aneurysm repair (EVAR) has been the most common type of repair since 2006. Multiple studies reflecting decreased perioperative morbidity and mortality over open repair make this an attractive option for patients. EVAR requires more intensive follow-up than standard open surgical repair, however. Secondary interventions are more common to maintain "seal" of the endograft within the aorta and subsequent exclusion of the aneurysmal component.
The term endoleak is specific to EVAR, and describes the primary means by which endografts fail. Type I endoleaks occur because of inadequate graft seal proximally or distally, resulting in perigraft flow and aneurysm sac pressurization. Type II endoleaks occur when branch arteries arising from the aneurysmal aorta back-bleed into the aneurysm sac due to collateral flow. Type III endoleaks occur when flow persists between segments of a modular graft. Type IV endoleaks occur when flow persists through endograft material (graft porosity). Type V endoleaks have also been called "endotension", and occur when pressurization of the sac occurs in the absence of any demonstrable endoleak. Type I and Type III endoleaks are most concerning for rupture, although persistent Type II endoleaks can also lead to aneurysm rupture and premature death.
The most common method of EVAR follow-up is computed tomographic angiography (CTA). These studies allow accurate measurement of aneurysm sac diameters and volumes. They also are highly sensitive and specific for endoleaks. Type II endoleaks are treated if they remain persistent and are present in the setting of aneurysm sac enlargement. Type I and III endoleaks are immediately treated when identified. Type IV endoleaks are rarely seen with current endograft technology.
Study Objectives:
The purpose of the current study is to compare routine postoperative surveillance by CTA with color duplex ultrasound and contrast enhanced ultrasound (CEUS) for the detection of endoleaks.
Study Design
This is a pilot study comparing the imaging techniques of CTA to CEUS in 25 patients undergoing EVAR at their one month post endograft surveillance. The one month standard follow-up will be used for comparing techniques as this will yield the highest number of endoleak positive patients. Patients will complete a color duplex examination in conjunction with CEUS using the FDA approved ultrasound contrast agent OptisonTM (Perflutren Protein Type A Microspheres for Injection, USP). Following ultrasonographic evaluation, study patients will undergo routine CTA.
Eligible subjects will be asked to participate in the trial following post-op day number 1 from their endovascular procedure. Study participation is ~30 days (+ 7 days).
연구 유형
등록 (실제)
단계
- 해당 없음
연락처 및 위치
연구 장소
-
-
Michigan
-
Ann Arbor, Michigan, 미국, 48109-5867
- University of Michigan
-
-
참여기준
자격 기준
공부할 수 있는 나이
건강한 자원 봉사자를 받아들입니다
연구 대상 성별
설명
Inclusion Criteria:
- 18 years old and greater
- Men or postmenopausal/non-pregnant women
- Abdominal aortic aneurysm successfully repaired by endograft deployment
- Creatinine < 2.0 mL
- Planned CTA follow-up
Exclusion Criteria:
- Subjects with known or suspected hypersensitivity to blood, blood products, or albumin.
- Subjects unable/unwilling to give informed consent
- Unable to complete post-operative imaging studies
- Subjects identified to have a cardiac shunt by TTE
- Subjects with hepatic or respiratory disease
- Nursing mothers
공부 계획
연구는 어떻게 설계됩니까?
디자인 세부사항
- 주 목적: 특수 증상
- 할당: 해당 없음
- 중재 모델: 단일 그룹 할당
- 마스킹: 없음(오픈 라벨)
무기와 개입
참가자 그룹 / 팔 |
개입 / 치료 |
|---|---|
|
다른: Endoleak imaging
In the single arm all participants are recieving both imaging techniques; CEUS and CTA
|
The contrast agent will be prepared using a single, 3 mL vial of Optison and 57 mL saline combined in a sterile syringe.
Contrast will be set to deliver a continuous infusion at 4 mL/min, via peripheral access.
In the event that the above description of the administration of Optison is not adequate for lumen flow contrast enhancement the PI or Co-I will direct the study team to proceed to the secondary administration procedure.
This will be done by the following: 0.5 mL of Optison will be injected into a peripheral vein.
This may be repeated for further contrast enhancement as needed.
The maximum total doses should not exceed 5.0 mL in any 10 minute period nor exceed 8.7 mL in any one patient study.
We will follow the insert package dose.
We will not not exceed 5.0 or 10 minutes or 8.7ml per patient (this will include the 0.5mL for initial).
Therefore, no more that 8.2mL will given in this second administration procedure.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
기간 |
|---|---|
|
Patient diagnosed with endoleak via CEUS and confirmed by CTA
기간: 30 days postoperative visit
|
30 days postoperative visit
|
공동 작업자 및 조사자
수사관
- 수석 연구원: Jon Eliason, MD, University of Michigan
연구 기록 날짜
연구 주요 날짜
연구 시작
기본 완료 (실제)
연구 완료 (실제)
연구 등록 날짜
최초 제출
QC 기준을 충족하는 최초 제출
처음 게시됨 (추정)
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
QC 기준을 충족하는 마지막 업데이트 제출
마지막으로 확인됨
추가 정보
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .