Contrast Enhanced Ultrasound vs. Computed Tomographic Angiography in the Detection of Endoleaks Following AAA Repair

24. oktober 2017 opdateret af: Jonathan Eliason, University of Michigan

Comparison of Contrast Enhanced Ultrasound and the Gold Standard Computed Tomographic Angiography in Detection of Endoleak Following Endovascular Abdominal Aortic Aneurysm Repair.

The purpose of the study is to compare two different types of imaging techniques to identify endoleaks. Following the endovascular procedure, subjects are seen at one month to have computed tomographic angiography (CTA) to confirm the graft is not leaking (endoleak). CTA is the standard imaging technique used to identify endoleaks. This study will investigate if the image technique color duplex ultrasound with contrast enhanced ultrasound (CEUS) is a good tool to identify endoleaks too.

Studieoversigt

Detaljeret beskrivelse

Background:

Abdominal aortic aneurysms (AAAs) continue to be a leading cause of death in older age groups. In the 60-85 year-old population, AAA represents the 14th-leading cause of death. Federal funding through Medicare has been allocated for early detection using abdominal ultrasound screening programs. Despite these more aggressive screening programs and concerted efforts by surgeons for timely repair, the incidence of ruptured AAA has continued to increase.

Endovascular aneurysm repair (EVAR) has been the most common type of repair since 2006. Multiple studies reflecting decreased perioperative morbidity and mortality over open repair make this an attractive option for patients. EVAR requires more intensive follow-up than standard open surgical repair, however. Secondary interventions are more common to maintain "seal" of the endograft within the aorta and subsequent exclusion of the aneurysmal component.

The term endoleak is specific to EVAR, and describes the primary means by which endografts fail. Type I endoleaks occur because of inadequate graft seal proximally or distally, resulting in perigraft flow and aneurysm sac pressurization. Type II endoleaks occur when branch arteries arising from the aneurysmal aorta back-bleed into the aneurysm sac due to collateral flow. Type III endoleaks occur when flow persists between segments of a modular graft. Type IV endoleaks occur when flow persists through endograft material (graft porosity). Type V endoleaks have also been called "endotension", and occur when pressurization of the sac occurs in the absence of any demonstrable endoleak. Type I and Type III endoleaks are most concerning for rupture, although persistent Type II endoleaks can also lead to aneurysm rupture and premature death.

The most common method of EVAR follow-up is computed tomographic angiography (CTA). These studies allow accurate measurement of aneurysm sac diameters and volumes. They also are highly sensitive and specific for endoleaks. Type II endoleaks are treated if they remain persistent and are present in the setting of aneurysm sac enlargement. Type I and III endoleaks are immediately treated when identified. Type IV endoleaks are rarely seen with current endograft technology.

Study Objectives:

The purpose of the current study is to compare routine postoperative surveillance by CTA with color duplex ultrasound and contrast enhanced ultrasound (CEUS) for the detection of endoleaks.

Study Design

This is a pilot study comparing the imaging techniques of CTA to CEUS in 25 patients undergoing EVAR at their one month post endograft surveillance. The one month standard follow-up will be used for comparing techniques as this will yield the highest number of endoleak positive patients. Patients will complete a color duplex examination in conjunction with CEUS using the FDA approved ultrasound contrast agent OptisonTM (Perflutren Protein Type A Microspheres for Injection, USP). Following ultrasonographic evaluation, study patients will undergo routine CTA.

Eligible subjects will be asked to participate in the trial following post-op day number 1 from their endovascular procedure. Study participation is ~30 days (+ 7 days).

Undersøgelsestype

Interventionel

Tilmelding (Faktiske)

4

Fase

  • Ikke anvendelig

Kontakter og lokationer

Dette afsnit indeholder kontaktoplysninger for dem, der udfører undersøgelsen, og oplysninger om, hvor denne undersøgelse udføres.

Studiesteder

    • Michigan
      • Ann Arbor, Michigan, Forenede Stater, 48109-5867
        • University of Michigan

Deltagelseskriterier

Forskere leder efter personer, der passer til en bestemt beskrivelse, kaldet berettigelseskriterier. Nogle eksempler på disse kriterier er en persons generelle helbredstilstand eller tidligere behandlinger.

Berettigelseskriterier

Aldre berettiget til at studere

18 år og ældre (Voksen, Ældre voksen)

Tager imod sunde frivillige

Ingen

Køn, der er berettiget til at studere

Alle

Beskrivelse

Inclusion Criteria:

  • 18 years old and greater
  • Men or postmenopausal/non-pregnant women
  • Abdominal aortic aneurysm successfully repaired by endograft deployment
  • Creatinine < 2.0 mL
  • Planned CTA follow-up

Exclusion Criteria:

  • Subjects with known or suspected hypersensitivity to blood, blood products, or albumin.
  • Subjects unable/unwilling to give informed consent
  • Unable to complete post-operative imaging studies
  • Subjects identified to have a cardiac shunt by TTE
  • Subjects with hepatic or respiratory disease
  • Nursing mothers

Studieplan

Dette afsnit indeholder detaljer om studieplanen, herunder hvordan undersøgelsen er designet, og hvad undersøgelsen måler.

Hvordan er undersøgelsen tilrettelagt?

Design detaljer

  • Primært formål: Diagnostisk
  • Tildeling: N/A
  • Interventionel model: Enkelt gruppeopgave
  • Maskning: Ingen (Åben etiket)

Våben og indgreb

Deltagergruppe / Arm
Intervention / Behandling
Andet: Endoleak imaging
In the single arm all participants are recieving both imaging techniques; CEUS and CTA
The contrast agent will be prepared using a single, 3 mL vial of Optison and 57 mL saline combined in a sterile syringe. Contrast will be set to deliver a continuous infusion at 4 mL/min, via peripheral access. In the event that the above description of the administration of Optison is not adequate for lumen flow contrast enhancement the PI or Co-I will direct the study team to proceed to the secondary administration procedure. This will be done by the following: 0.5 mL of Optison will be injected into a peripheral vein. This may be repeated for further contrast enhancement as needed. The maximum total doses should not exceed 5.0 mL in any 10 minute period nor exceed 8.7 mL in any one patient study. We will follow the insert package dose. We will not not exceed 5.0 or 10 minutes or 8.7ml per patient (this will include the 0.5mL for initial). Therefore, no more that 8.2mL will given in this second administration procedure.

Hvad måler undersøgelsen?

Primære resultatmål

Resultatmål
Tidsramme
Patient diagnosed with endoleak via CEUS and confirmed by CTA
Tidsramme: 30 days postoperative visit
30 days postoperative visit

Samarbejdspartnere og efterforskere

Det er her, du vil finde personer og organisationer, der er involveret i denne undersøgelse.

Efterforskere

  • Ledende efterforsker: Jon Eliason, MD, University of Michigan

Datoer for undersøgelser

Disse datoer sporer fremskridtene for indsendelser af undersøgelsesrekord og resumeresultater til ClinicalTrials.gov. Studieregistreringer og rapporterede resultater gennemgås af National Library of Medicine (NLM) for at sikre, at de opfylder specifikke kvalitetskontrolstandarder, før de offentliggøres på den offentlige hjemmeside.

Studer store datoer

Studiestart

1. december 2010

Primær færdiggørelse (Faktiske)

1. november 2011

Studieafslutning (Faktiske)

1. november 2011

Datoer for studieregistrering

Først indsendt

28. oktober 2010

Først indsendt, der opfyldte QC-kriterier

28. oktober 2010

Først opslået (Skøn)

29. oktober 2010

Opdateringer af undersøgelsesjournaler

Sidste opdatering sendt (Faktiske)

26. oktober 2017

Sidste opdatering indsendt, der opfyldte kvalitetskontrolkriterier

24. oktober 2017

Sidst verificeret

1. oktober 2017

Mere information

Begreber relateret til denne undersøgelse

Andre undersøgelses-id-numre

  • HUM00038554
  • Internal Grant Award (Andet bevillings-/finansieringsnummer: G009310/Cardiovascular Center)

Disse oplysninger blev hentet direkte fra webstedet clinicaltrials.gov uden ændringer. Hvis du har nogen anmodninger om at ændre, fjerne eller opdatere dine undersøgelsesoplysninger, bedes du kontakte register@clinicaltrials.gov. Så snart en ændring er implementeret på clinicaltrials.gov, vil denne også blive opdateret automatisk på vores hjemmeside .

Kliniske forsøg med Contrast Enhanced Ultrasound (Contrast Agent: OptisonTM)

Abonner