Background:
Abdominal aortic aneurysms (AAAs) continue to be a leading cause of death in older age groups. In the 60-85 year-old population, AAA represents the 14th-leading cause of death. Federal funding through Medicare has been allocated for early detection using abdominal ultrasound screening programs. Despite these more aggressive screening programs and concerted efforts by surgeons for timely repair, the incidence of ruptured AAA has continued to increase.
Endovascular aneurysm repair (EVAR) has been the most common type of repair since 2006. Multiple studies reflecting decreased perioperative morbidity and mortality over open repair make this an attractive option for patients. EVAR requires more intensive follow-up than standard open surgical repair, however. Secondary interventions are more common to maintain "seal" of the endograft within the aorta and subsequent exclusion of the aneurysmal component.
The term endoleak is specific to EVAR, and describes the primary means by which endografts fail. Type I endoleaks occur because of inadequate graft seal proximally or distally, resulting in perigraft flow and aneurysm sac pressurization. Type II endoleaks occur when branch arteries arising from the aneurysmal aorta back-bleed into the aneurysm sac due to collateral flow. Type III endoleaks occur when flow persists between segments of a modular graft. Type IV endoleaks occur when flow persists through endograft material (graft porosity). Type V endoleaks have also been called "endotension", and occur when pressurization of the sac occurs in the absence of any demonstrable endoleak. Type I and Type III endoleaks are most concerning for rupture, although persistent Type II endoleaks can also lead to aneurysm rupture and premature death.
The most common method of EVAR follow-up is computed tomographic angiography (CTA). These studies allow accurate measurement of aneurysm sac diameters and volumes. They also are highly sensitive and specific for endoleaks. Type II endoleaks are treated if they remain persistent and are present in the setting of aneurysm sac enlargement. Type I and III endoleaks are immediately treated when identified. Type IV endoleaks are rarely seen with current endograft technology.
Study Objectives:
The purpose of the current study is to compare routine postoperative surveillance by CTA with color duplex ultrasound and contrast enhanced ultrasound (CEUS) for the detection of endoleaks.
Study Design
This is a pilot study comparing the imaging techniques of CTA to CEUS in 25 patients undergoing EVAR at their one month post endograft surveillance. The one month standard follow-up will be used for comparing techniques as this will yield the highest number of endoleak positive patients. Patients will complete a color duplex examination in conjunction with CEUS using the FDA approved ultrasound contrast agent OptisonTM (Perflutren Protein Type A Microspheres for Injection, USP). Following ultrasonographic evaluation, study patients will undergo routine CTA.
Eligible subjects will be asked to participate in the trial following post-op day number 1 from their endovascular procedure. Study participation is ~30 days (+ 7 days).
Typ studie
Zápis (Aktuální)
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Michigan
-
Ann Arbor, Michigan, Spojené státy, 48109-5867
- University of Michigan
-
-
Kritéria účasti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- 18 years old and greater
- Men or postmenopausal/non-pregnant women
- Abdominal aortic aneurysm successfully repaired by endograft deployment
- Creatinine < 2.0 mL
- Planned CTA follow-up
Exclusion Criteria:
- Subjects with known or suspected hypersensitivity to blood, blood products, or albumin.
- Subjects unable/unwilling to give informed consent
- Unable to complete post-operative imaging studies
- Subjects identified to have a cardiac shunt by TTE
- Subjects with hepatic or respiratory disease
- Nursing mothers
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Diagnostický
- Přidělení: N/A
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Zbraně a zásahy
Skupina účastníků / Arm |
Intervence / Léčba |
|---|---|
|
Jiný: Endoleak imaging
In the single arm all participants are recieving both imaging techniques; CEUS and CTA
|
The contrast agent will be prepared using a single, 3 mL vial of Optison and 57 mL saline combined in a sterile syringe.
Contrast will be set to deliver a continuous infusion at 4 mL/min, via peripheral access.
In the event that the above description of the administration of Optison is not adequate for lumen flow contrast enhancement the PI or Co-I will direct the study team to proceed to the secondary administration procedure.
This will be done by the following: 0.5 mL of Optison will be injected into a peripheral vein.
This may be repeated for further contrast enhancement as needed.
The maximum total doses should not exceed 5.0 mL in any 10 minute period nor exceed 8.7 mL in any one patient study.
We will follow the insert package dose.
We will not not exceed 5.0 or 10 minutes or 8.7ml per patient (this will include the 0.5mL for initial).
Therefore, no more that 8.2mL will given in this second administration procedure.
|
Co je měření studie?
Primární výstupní opatření
Měření výsledku |
Časové okno |
|---|---|
|
Patient diagnosed with endoleak via CEUS and confirmed by CTA
Časové okno: 30 days postoperative visit
|
30 days postoperative visit
|
Spolupracovníci a vyšetřovatelé
Sponzor
Vyšetřovatelé
- Vrchní vyšetřovatel: Jon Eliason, MD, University of Michigan
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia
Primární dokončení (Aktuální)
Dokončení studie (Aktuální)
Termíny zápisu do studia
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Odhad)
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další relevantní podmínky MeSH
Další identifikační čísla studie
- HUM00038554
- Internal Grant Award (Jiné číslo grantu/financování: G009310/Cardiovascular Center)
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .
Klinické studie na Contrast Enhanced Ultrasound (Contrast Agent: OptisonTM)
-
Medical University of South CarolinaSouth Carolina Spinal Cord Injury Research FundDokončenoNemoci míchy | Spinální stenóza | Poranění míchy | Degenerace páteře | Komprese míchy | Onemocnění páteře | Poranění páteřeSpojené státy