- ICH GCP
- 미국 임상 시험 레지스트리
- 임상시험 NCT01573390
Non Invasive and Non-Contact Imaging Of Tissue Oxygenation and Vascular Reactivity
2022년 4월 20일 업데이트: Chandan K Sen
Non Invasive and Non-Contact Dual-modal Imaging Of Tissue Oxygenation and Vascular Reactivity Dynamic Imaging Of Tissue Metabolism and Vascular Function.
- Quantitative validation of non-contact oxygenation imaging by the CWC imaging system
- Quantitative validation of non-contact vascular function imaging by the CWC imaging system
- Evaluation of the clinical usability of the CWC imaging system for further technology development and engineering improvement
연구 개요
상세 설명
The hyperspectral imaging technique estimates cutaneous tissue oxygenation by illuminating tissue and detecting tissue reflectance at different wavelengths.
One major advantage of hyperspectral imaging is non-invasive and non-contact detection of tissue functional properties.
The dual-mode imaging system integrates hyperspectral and thermal imaging modalities for simultaneous assessment of cutaneous tissue oxygenation and vascular function.
This clinical protocol is defined to validate the CWC system on healthy human subjects
연구 유형
관찰
연락처 및 위치
이 섹션에서는 연구를 수행하는 사람들의 연락처 정보와 이 연구가 수행되는 장소에 대한 정보를 제공합니다.
연구 장소
-
-
Ohio
-
Columbus, Ohio, 미국, 43210
- The Ohio State University.
-
-
참여기준
연구원은 적격성 기준이라는 특정 설명에 맞는 사람을 찾습니다. 이러한 기준의 몇 가지 예는 개인의 일반적인 건강 상태 또는 이전 치료입니다.
자격 기준
공부할 수 있는 나이
18년 이상 (성인, 고령자)
건강한 자원 봉사자를 받아들입니다
예
연구 대상 성별
모두
샘플링 방법
확률 샘플
연구 인구
Interested healthy volunteers
설명
Inclusion Criteria:
- Adult 18 years and older
- No history of diabetes.
- No history of vascular disease
Exclusion Criteria:
- Under 18 years of age
- Unable to provide informed consent
- Prisoners
- Current smoker
공부 계획
이 섹션에서는 연구 설계 방법과 연구가 측정하는 내용을 포함하여 연구 계획에 대한 세부 정보를 제공합니다.
연구는 어떻게 설계됩니까?
디자인 세부사항
코호트 및 개입
그룹/코호트 |
|---|
|
1
Healthy participants.
|
연구는 무엇을 측정합니까?
주요 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Non-Contact Oxygenation Imagiing
기간: 1 year
|
Quantitative validation of non-contact oxygenation imaging by the CWC imaging system
|
1 year
|
|
Non-Contact Vascular Function Imaging
기간: 1 year
|
Quantitative validation of non-contact vascular function imaging by the CWC imaging system
|
1 year
|
2차 결과 측정
결과 측정 |
측정값 설명 |
기간 |
|---|---|---|
|
Clinical usability for Comprehensive Wound Centers
기간: 1 year
|
Evaluation of the clinical usability of the CWC imaging system for further technology development and engineering improvement.
|
1 year
|
공동 작업자 및 조사자
여기에서 이 연구와 관련된 사람과 조직을 찾을 수 있습니다.
스폰서
수사관
- 수석 연구원: Chandan K Sen, Ph.D., Ohio State University
간행물 및 유용한 링크
연구에 대한 정보 입력을 담당하는 사람이 자발적으로 이러한 간행물을 제공합니다. 이것은 연구와 관련된 모든 것에 관한 것일 수 있습니다.
일반 간행물
- Sen CK. Wound healing essentials: let there be oxygen. Wound Repair Regen. 2009 Jan-Feb;17(1):1-18. doi: 10.1111/j.1524-475X.2008.00436.x.
- Xu RX, Huang K, Qin R, Huang J, Xu JS, Ding L, Gnyawali US, Gordillo GM, Gnyawali SC, Sen CK. Dual-mode imaging of cutaneous tissue oxygenation and vascular function. J Vis Exp. 2010 Dec 8;(46):2095. doi: 10.3791/2095.
- Singer AJ, Clark RA. Cutaneous wound healing. N Engl J Med. 1999 Sep 2;341(10):738-46. doi: 10.1056/NEJM199909023411006. No abstract available.
- Reiber GE. Diabetic foot care. Financial implications and practice guidelines. Diabetes Care. 1992 Mar;15 Suppl 1:29-31. doi: 10.2337/diacare.15.1.s29.
- Broughton G 2nd, Janis JE, Attinger CE. Wound healing: an overview. Plast Reconstr Surg. 2006 Jun;117(7 Suppl):1e-S-32e-S. doi: 10.1097/01.prs.0000222562.60260.f9.
- Leach RM, Treacher DF. Oxygen transport-2. Tissue hypoxia. BMJ. 1998 Nov 14;317(7169):1370-3. doi: 10.1136/bmj.317.7169.1370. No abstract available.
- Treacher DF, Leach RM. Oxygen transport-1. Basic principles. BMJ. 1998 Nov 7;317(7168):1302-6. doi: 10.1136/bmj.317.7168.1302. No abstract available.
- Chang N, Goodson WH 3rd, Gottrup F, Hunt TK. Direct measurement of wound and tissue oxygen tension in postoperative patients. Ann Surg. 1983 Apr;197(4):470-8. doi: 10.1097/00000658-198304000-00017.
- Wilson DF. Oxygen dependent quenching of phosphorescence: a perspective. Adv Exp Med Biol. 1992;317:195-201. doi: 10.1007/978-1-4615-3428-0_20.
- Griffiths JR, Robinson SP. The OxyLite: a fibre-optic oxygen sensor. Br J Radiol. 1999 Jul;72(859):627-30. doi: 10.1259/bjr.72.859.10624317. No abstract available.
- Scheffler A, Rieger H. Clinical information content of transcutaneous oxymetry (tcpO2) in peripheral arterial occlusive disease (a review of the methodological and clinical literature with a special reference to critical limb ischaemia). Vasa. 1992;21(2):111-26.
- Barker SJ, Tremper KK. Pulse oximetry: applications and limitations. Int Anesthesiol Clin. 1987 Fall;25(3):155-75. doi: 10.1097/00004311-198702530-00010.
- Shah SA, Bachrach N, Spear SJ, Letbetter DS, Stone RA, Dhir R, Prichard JW, Brown HG, LaFramboise WA. Cutaneous wound analysis using hyperspectral imaging. Biotechniques. 2003 Feb;34(2):408-13. doi: 10.2144/03342pf01.
- Zweier JL, Thompson-Gorman S, Kuppusamy P. Measurement of oxygen concentrations in the intact beating heart using electron paramagnetic resonance spectroscopy: a technique for measuring oxygen concentrations in situ. J Bioenerg Biomembr. 1991 Dec;23(6):855-71. doi: 10.1007/BF00786005.
- Ogawa S, Lee TM, Kay AR, Tank DW. Brain magnetic resonance imaging with contrast dependent on blood oxygenation. Proc Natl Acad Sci U S A. 1990 Dec;87(24):9868-72. doi: 10.1073/pnas.87.24.9868.
- Valk PE, Mathis CA, Prados MD, Gilbert JC, Budinger TF. Hypoxia in human gliomas: demonstration by PET with fluorine-18-fluoromisonidazole. J Nucl Med. 1992 Dec;33(12):2133-7.
- Hosokawa R, Nohara R, Fujibayashi Y, Okuda K, Ogino M, Hirai T, Fujita M, Tamaki N, Konishi J, Sasayama S. Myocardial metabolism of 123I-BMIPP in a canine model with ischemia: implications of perfusion-metabolism mismatch on SPECT images in patients with ischemic heart disease. J Nucl Med. 1999 Mar;40(3):471-8.
- Djordjevich L, Sadove MS. Basic principles of electrohaemodynamics. J Biomed Eng. 1981 Jan;3(1):25-33. doi: 10.1016/0141-5425(81)90101-1.
- Kongstad L, Grande PO. The role of arterial and venous pressure for volume regulation of an organ enclosed in a rigid compartment with application to the injured brain. Acta Anaesthesiol Scand. 1999 May;43(5):501-8. doi: 10.1034/j.1399-6576.1999.430503.x.
- Whiston R. Wound care. Principles of Doppler. Nurs Times. 1996 May 15-21;92(20):66-70. No abstract available.
- Luypaert R, Boujraf S, Sourbron S, Osteaux M. Diffusion and perfusion MRI: basic physics. Eur J Radiol. 2001 Apr;38(1):19-27. doi: 10.1016/s0720-048x(01)00286-8.
- Khan F, Newton DJ. Laser Doppler imaging in the investigation of lower limb wounds. Int J Low Extrem Wounds. 2003 Jun;2(2):74-86. doi: 10.1177/1534734603256271.
- Hlavova A, Linhart J, Provsky I, Ganz V, Fronek A. Measurement of blood flow in the femoral artery in man at rest and during exercise by local thermodilution. Scand J Clin Lab Invest Suppl. 1967;99:86-9. No abstract available.
- Johnson LL, Seldin DW. Clinical experience with technetium-99m teboroxime, a neutral, lipophilic myocardial perfusion imaging agent. Am J Cardiol. 1990 Oct 16;66(13):63E-67E. doi: 10.1016/0002-9149(90)90614-7.
- Kupriyanov VV, Nighswander-Rempel S, Xiang B. Mapping regional oxygenation and flow in pig hearts in vivo using near-infrared spectroscopic imaging. J Mol Cell Cardiol. 2004 Nov;37(5):947-57. doi: 10.1016/j.yjmcc.2004.07.007.
- Greenman RL, Panasyuk S, Wang X, Lyons TE, Dinh T, Longoria L, Giurini JM, Freeman J, Khaodhiar L, Veves A. Early changes in the skin microcirculation and muscle metabolism of the diabetic foot. Lancet. 2005 Nov 12;366(9498):1711-7. doi: 10.1016/S0140-6736(05)67696-9.
- Myers DE, Anderson LD, Seifert RP, Ortner JP, Cooper CE, Beilman GJ, Mowlem JD. Noninvasive method for measuring local hemoglobin oxygen saturation in tissue using wide gap second derivative near-infrared spectroscopy. J Biomed Opt. 2005 May-Jun;10(3):034017. doi: 10.1117/1.1925250.
- Khaodhiar L, Dinh T, Schomacker KT, Panasyuk SV, Freeman JE, Lew R, Vo T, Panasyuk AA, Lima C, Giurini JM, Lyons TE, Veves A. The use of medical hyperspectral technology to evaluate microcirculatory changes in diabetic foot ulcers and to predict clinical outcomes. Diabetes Care. 2007 Apr;30(4):903-10. doi: 10.2337/dc06-2209. Epub 2007 Feb 15.
- Khoobehi B, Beach JM, Kawano H. Hyperspectral imaging for measurement of oxygen saturation in the optic nerve head. Invest Ophthalmol Vis Sci. 2004 May;45(5):1464-72. doi: 10.1167/iovs.03-1069.
- Jarm T, Kragelj R, Liebert A, Lukasiewitz P, Erjavec T, Preseren-Strukelj M, Maniewski R, Poredos P, Miklavcic D. Postocclusive reactive hyperemia in healthy volunteers and patients with peripheral vascular disease measured by three noninvasive methods. Adv Exp Med Biol. 2003;530:661-9. doi: 10.1007/978-1-4615-0075-9_66.
- Hueber DM, Franceschini MA, Ma HY, Zhang Q, Ballesteros JR, Fantini S, Wallace D, Ntziachristos V, Chance B. Non-invasive and quantitative near-infrared haemoglobin spectrometry in the piglet brain during hypoxic stress, using a frequency-domain multidistance instrument. Phys Med Biol. 2001 Jan;46(1):41-62. doi: 10.1088/0031-9155/46/1/304.
- Franceschini MA, Moesta KT, Fantini S, Gaida G, Gratton E, Jess H, Mantulin WW, Seeber M, Schlag PM, Kaschke M. Frequency-domain techniques enhance optical mammography: initial clinical results. Proc Natl Acad Sci U S A. 1997 Jun 10;94(12):6468-73. doi: 10.1073/pnas.94.12.6468.
연구 기록 날짜
이 날짜는 ClinicalTrials.gov에 대한 연구 기록 및 요약 결과 제출의 진행 상황을 추적합니다. 연구 기록 및 보고된 결과는 공개 웹사이트에 게시되기 전에 특정 품질 관리 기준을 충족하는지 확인하기 위해 국립 의학 도서관(NLM)에서 검토합니다.
연구 등록 날짜
최초 제출
2012년 4월 5일
QC 기준을 충족하는 최초 제출
2012년 4월 5일
처음 게시됨 (추정)
2012년 4월 9일
연구 기록 업데이트
마지막 업데이트 게시됨 (실제)
2022년 4월 28일
QC 기준을 충족하는 마지막 업데이트 제출
2022년 4월 20일
마지막으로 확인됨
2022년 4월 1일
추가 정보
이 연구와 관련된 용어
기타 연구 ID 번호
- 2010H0017
이 정보는 변경 없이 clinicaltrials.gov 웹사이트에서 직접 가져온 것입니다. 귀하의 연구 세부 정보를 변경, 제거 또는 업데이트하도록 요청하는 경우 register@clinicaltrials.gov. 문의하십시오. 변경 사항이 clinicaltrials.gov에 구현되는 즉시 저희 웹사이트에도 자동으로 업데이트됩니다. .